background image

Содержание OZCO 342 IW

Страница 1: ...ject Plans are effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information OZCO Project 342 IW Patio Pergola OZCO Project 342 IW Patio Pergola 1 ...

Страница 2: ......

Страница 3: ... effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information 13 6 1 8 6 9 1 16 Overview Front OZCO Project 342 IW Patio Pergola 3 16 0 1 0 7 10 5 8 9 4 1 8 1 0 ...

Страница 4: ... Plans are effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information 6 6 typ 1 2 typ Overview Top OZCO Project 342 IW Patio Pergola 4 C L 16 0 12 0 ...

Страница 5: ...ct Plans are effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information 9 0 Overview Right OZCO Project 342 IW Patio Pergola 5 12 0 1 7 7 8 10 1 4 ...

Страница 6: ...ons and Project Plans are effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information Translucent OZCO Project 342 IW Patio Pergola 6 ...

Страница 7: ...PTION 1 5 51708 6x6 Post Base 6x6 PB IW 2 2 51768 4 Flush Inside 45 FI45 IW 4 3 12 56651 OWT Timber Bolt 8 10 12 56680 2 Timber Bolt Heavy Duty Washer OWT TBW 2 4 3 51717 2 Standard Rafter Clip RC IW 2 5 6 56651 OWT Timber Bolt 8 10 6 1 56677 8 Post to Beam Coupler P2B SB IW 7 4 51737 Bolt Inline P2B BI IW 8 5 6x6 Cedar Post 6x6x8 7 13 16 9 4 2x10 Cedar Board 2x10x8 0 10 13 2x6 Cedar Board 2x6x12 ...

Страница 8: ...se visit OZCOBP com to get current information Material List OZCO Project 342 IW Patio Pergola 8 QTY PART NUMBER DESCRIPTION 5 51708 6x6 Post Base 6x6 PB IW 3 51717 2 Standard Rafter Clip RC IW 2 6 56651 OWT Timber Bolt 8 10 1 51777 8 Post to Beam Coupler P2B SB IW 4 51737 Post to Beam Bolt Inline P2B BI IW 5 6x6x8L 6x6x8 4 2x10x8L 2x10x8 2 2x10x16L 2x10x16 13 2x6x12L 2x6x12 23 2x2x16L 2x2x16 ...

Страница 9: ...ct Plans are effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information Suggested Tools others may be required OZCO Project 342 IW Patio Pergola 8 ...

Страница 10: ...lans are effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information 51768 51777 51737 51717 OZCO OZCO Project 342 IW Patio Pergola 9 56680 51708 56651 ...

Страница 11: ... after 2 years from 4 27 2017 Please visit OZCOBP com to get current information 1 2 X 45 both ends see template 1 2x10 Cedar Board 8 with Decora cut Cutlist OZCO Project 342 IW Patio Pergola 10 2x2 Cedar Board 16 with chamfer on both ends see template 1 2x10 Cedar Board 16 with Decora cut both ends see template 2 2x6 Cedar Board 12 with Decora cut both ends ...

Страница 12: ... are effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information Template 1 OZCO Project 342 IW Patio Pergola 11 SCALE 1 2 2 1 2 R2 1 2 R4 1 2 7 1 3 8 1 2 ...

Страница 13: ...ans are effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information Template 2 OZCO Project 342 IW Patio Pergola 12 SCALE 1 2 5 3 8 R3 R2 1 2 2 1 2 3 4 ...

Страница 14: ...n is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information 16 2 13 16 13 6 1 8 9 0 6 9 1 16 site plan OZCO Project 342 IW Patio Pergola 13 Locate desired center of structure if site is not level see Ozco Site Leveling instruction ...

Страница 15: ...ctive 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information step 1 OZCO Project 342 IW Patio Pergola 14 Tool Required 3 8 Driver Hex Cap Nut provided OWT Screw provided ...

Страница 16: ...s updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information step 2 OZCO Project 342 IW Patio Pergola 15 see Overview Front page for Beam spacing 2x10x16 Beams 2x10x8 Beams Tool Required 3 8 Driver Hex Cap Nut provided OWT Screw provided ...

Страница 17: ...re effective 4 27 2017 This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information step 3 OZCO Project 342 IW Patio Pergola 16 see Overview Right page for Rafter spacing Rafter ...

Страница 18: ...This information is updated periodically and should not be relied upon after 2 years from 4 27 2017 Please visit OZCOBP com to get current information step 4 OZCO Project 342 IW Patio Pergola 17 chamfer facing down secure with nails or screws see Overview Top page for Purlin spacing Purlin ...

Отзывы: