Страница 2: ...that in the materials published originally The information in this manual was correct at the time of printing However LILLIPUT will continue to improve products and reserves the rights to change specification at any time without notice is the registered trademark of the LILLIPUT Company Fujian LILLIPUT Optoelectronics Technology Co Ltd No 19 Heming Road Lantian Industrial Zone Zhangzhou 363005 P R...

Страница 3: ... copy of the customers proof of purchase is also required This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care We shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than our company representatives to install repair or service the product b to repa...

Страница 4: ...el Output 7 4 2 Set the Output Voltage Current 7 4 3 Over Voltage Current Protection 7 4 4 Memory key shortcut settings 8 4 4 1 Quick output 8 4 4 2 Edit 8 4 5 System Settings 9 4 5 1 Display Brightness 9 4 5 2 Language Setting 9 4 5 3 Buzzer 9 4 5 4 Display 9 4 6 Interface Setting 12 4 7 System Information 13 4 7 1 Review System Information 13 4 7 2 Restore Factory Settings 13 5 Troubleshooting 1...

Страница 5: ... the user manual for more information about ratings before connecting to the instrument Do not operate without covers Do not operate the instrument with covers or panels removed Use the Proper Fuse Use only the specified type and rating fuse for this instrument Avoid exposed circuit Be careful when working on exposed circuitry to avoid risk of electric shock or other injury Do not operate if any d...

Страница 6: ...es that could result in damage to this product or other property Terms on the product The following terms may appear on this product Danger Indicates an immediate hazard or injury possibility Warning Indicates a possible hazard or injury Caution Indicates potential damage to the instrument or other property Safety Symbols Symbols on the product The following symbols may appear on the product Hazar...

Страница 7: ...ect menu select parameters Edit the cursor OK Key 1 Enter the menu or confirm the entered parameters 2 Switch the display mode between Number and Curve Knob Select the main menu or change the value function equals to the confirmation key On Off Key Turn on off the channel Channel Output Terminal Output access of channel Power Button Turn on off the instrument ...

Страница 8: ... about 5 seconds When you hear a beep the panel is unlocked Memory Key 5 sets of channel parameters can be stored for quick output System Key System settings interface settings system information Button light instruction On Off key The key lights up when the channel turns on 3 1 2 Rear Panel Figure 3 2 Rear Panel Overview AC Power Input Jack AC power input interface Fuse Power fuse Air Vent Air ve...

Страница 9: ...nical property tests 2 Check the Accessories The supplied accessories have been already described in the Appendix A Enclosure of this Manual You can check whether there is any loss of accessories with reference to this description If it is found that there is any accessory lost or damaged please get in touch with the distributor of our responsible for this service or the our local offices 3 Check ...

Страница 10: ... the actual voltage value displayed is close to the set voltage value and also that the actual current value displayed is nearly to zero 4 Check that if the output voltage can be adjusted from zero to the maximum rating When it is set to the maximum or minimum a beep is heard indicating that the limit has been reached 3 4 2 Current Output Inspection The following steps check basic current function...

Страница 11: ... V P or overcurrent protection O C P after the output is turned on once the output voltage current reaches the set value of O V P O C P the instrument will cut off the output a warning will show on the screen Note When the instrument disables the output due to protection after you make some adjustments the channel must be restarted to output normally This function can keep the power output from ex...

Страница 12: ... will display 2 Press key and shows the yellow select box Press to move the select box 3 After selecting the certain parameter press knob or OK on the panel to confirm the input value Set values of voltage Set values of current Set values of O V P Set values of O C P 4 4 2 Edit To edit the channel parameters of M1 to M5 follow these steps 1 Press the front panel Memory button the screen displays t...

Страница 13: ... the language Press the arrow keys to select the desired language Supported languages include Chinese and English 4 5 3 Buzzer Press the System softkey and turn the knob to select the Utility menu Press the arrow keys to choose buzzer submenu Press the arrow keys to toggle the beeper on off When the buzzer is on the status bar icon lights up When the system prompts it beeps such as when the output...

Страница 14: ...eys to choose Display submenu Press the arrow keys or turn the knob to set the display mode to Curve In system main interface you can also press the OK key or press the knob to select the Curve display mode Curve Type You can set the type of the displayed curve to voltage curve or current curve 1 Voltage Curve Two methods to set the curve type to voltage curve 1st Method Press the System softkey a...

Страница 15: ...ng mode will be exited 2 Current Curve Two methods to set the curve type to current curve 1st Method Press the System softkey and turn the knob to select the Utility menu Press the arrow keys to choose Display submenu Press the arrow keys or turn the knob to set the display mode to Curve Press the arrow keys to choose CurveType submenu press the arrow keys or turn the knob to set the curve type to...

Страница 16: ...choose CurveTime submenu Press the arrow keys or turn the knob to set the display mode to Curve Press the arrow keys to choose CurveTime submenu press the arrow keys or turn the knob to set the curve time to 30S or 60S 4 6 Interface Setting 1 Press the arrow keys to select the baud rate and press the arrow keys to set the baud rate of the RS232 serial interface The optional values for the baud rat...

Страница 17: ...ess the System softkey and turn the knob to select the SYSTEM menu The screen shows the model number version number serial number and checksum of the machine 4 7 2 Restore Factory Settings Press the System softkey and turn the knob to select the SYSTEM menu Press arrow keys to select the Factory Reset submenu Press OK to restore the factory default settings See the factory setting detail table bel...

Страница 18: ...our service 2 The output is abnormal Check if the output voltage is set to 0V If so set it to other value Check if the output current is set to 0A If so set it to other value When in programmable output status check if there is any voltage current value is set to 0 If so set it to other value If the problem still exists please contact our for our service 6 Appendix 6 1 Appendix A Accessories The a...

Страница 19: ... exterior perform the following steps Wipe the dust from the instrument surface with a soft cloth Take care not to scratch the transparent LCD protection screen when cleaning Disconnect power before cleaning your instrument Clean the instrument with a damp soft cloth not dripping with water It is recommended to clean with soft detergent or fresh water To avoid damage to the instrument do not use a...