ZigBee Multi-Sensor

Quick Start Guide

Содержание 323

Страница 1: ...1 ZigBee Multi Sensor Quick Start Guide ...

Страница 2: ... notices below before using the ZigBee Multi Sensor Avoid high humidity or extreme temperatures Avoid long exposure to direct sunlight or strong ultraviolet light Do not drop or expose the unit to intense vibration Do not disassemble or try to repair the unit on your own Do not expose the unit or its accessories to flammable liquids gases or other explosives Safety Handling ...

Страница 3: ...igBee Profile ZigBee 3 0 RF Characteristics Operating frequency 2 4GHz Range outdoor indoor 100m 30m Open area Internal PCB Antenna Physical Specifications Battery DC 3V Two AAA batteries LED 2 color LED Red Green Operating environment Temperature 10 55 Humidity 85 non condensing ...

Страница 4: ...Detecting range PIR Distance 5m Angle up down 100 left right 120 Dimensions 62 L 62 W 15 5 H mm Line length of remote probe External temperature 2 5m Optinal Mounting Type Tabletop stand or Wall mounting ...

Страница 5: ...remote probe It is available to detect motion vibration and allows you to receive notifications from mobile app The above functions can be customized please use this guide according to your customized functions This guide will provide you with an overview of the product and help you get through the initial setup Welcome 1 ...

Страница 6: ...n and secure You can peel off the tape on the back or lock it with screws ZigBee 3 0 PIR motion detection Optional Vibration detection Optional Environmental temperature humidity measuring Optional External temperature probe Optional Available for water measurement Low power consumption Features 2 PIR Vibration Environmental temperature humidity function ...

Страница 7: ...nting the Multi sensor close to pets air conditioners heaters sunshine or places where the temperature varies 2 You need to pay attention to the distance and range of the sensor when installing 2 1m 1m 3m 5m 100 120 ...

Страница 8: ...e probe Please refer to the mounting example below You can measure the temperature by touching the probe with the measured object Such as water floor metal etc But don t put it in the environment with strong acid and alkali ...

Страница 9: ...D flashes once Motion detected When you press the reset button once Flashing green Device has joined a ZigBee network Flashing red Device has not joined a ZigBee network LED indicator The LED status gives the following information LED indicator Reset button 3 ...

Страница 10: ...s again at tenth second 4 1 To get started you will need A Zigbee Gateway A mobile phone with a mobile APP installed 4 2 Adding to the gateway s network 1 Set your gateway to permit joining see your gateway s manual 2 Power on the Multi sensor and press the reset button once to make sure the LED indicator is flashing red If not reset it Configure Network 4 ...

Страница 11: ...nsor is in the range of gateway s network After few seconds the Multi sensor will join the gateway automatically and the LED indicator will flash green when it successfully joined Note If the adding is failed simply reset the Multi sensor and retry ...