Owlee 51-05 Largo Скачать руководство пользователя страница 2

Cover - Important Safety Information

1

Table Of Contents

2

Important Safety Information

Minimum Clearances to Combustibles

2

Pre-Installation & Preparation Guidelines

3

Installation Information

Connecting the Gas to the Fire Pit

5

Certified Media List

6

Glass Media Installation

6

Gem, Mirrored and Tumbled Glass Installation

7

Ceramic Rock and Sphere Media Installation

8

Operation Instructions

9

Lighting Instructions

9

Operating Instructions

4

Conversion to a Different Gas Type

10

A.

B.

C.

D.

       

Page 2

The dimensions shown in Figure 1 are MINIMUM
CLEARANCES to maintain when you install this Outdoor 
Fire Pit.  THERE MUST BE AT LEAST 60” of clearance 
from the center of the unit  to any combustible sidewalls, 
ceilings, or material.

Figure 1

OUTDOOR FIRE PIT - TABLE OF CONTENTS

IMPORTANT SAFETY INFORMATION

READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.

If not installed and used correctly per these instructions, this product can cause serious injury.

Be sure you understand all safety precautions and warnings contained in this manual.

CHECK STATE AND LOCAL CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN
YOUR LOCALITY BEFORE INSTALLATION.

Clearances to Combustible Construction:

Sidewalls:  60”  (1.5 m) from center of unit (Figure 1)
Ceiling:  60” (1.5 m) from top of unit to ceiling or overhang
Flooring:  0” – Can be installed on deck, slab, floor, etc.

CAUTION:  INSTALLATION, MODIFICATION AND REPAIR MUST BE DONE BY

A CERTIFIED, PROFESSIONAL TECHNICIAN or LICENCED PLUMBER.

FOR OUTDOOR USE ONLY.  THIS UNIT MUST BE INSTALLED AT LEAST 60” FROM CENTER OF BURNER 
TO ANY COMBUSTIBLE WALLS, CEILINGS, OR MATERIAL.

When shutting the unit down—be sure to TURN THE CONTROL VALVE FULLY OFF.

WARNING:  CARBON MONOXIDE POISONING MAY LEAD TO DEATH.  DO NOT MODIFY THIS OUTDOOR 
FIRE PIT OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL.

If you have any questions, please contact O.W. Lee at (800) 776-9533

Any other change may be dangerous.  Improper installation or use of your Outdoor Fire Pit can cause serious 
injury or death from fire, burns, explosions or carbon monoxide poisoning.

MINIMUM CLEARANCE TO COMBUSTIBLES

NOTE

MINIMUM OF 60” (1.5 m) CLEARANCE ABOVE THE 

OUTDOOR FIRE PIT IF INSTALLED UNDER CEILING OR 

OVERHANG 

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY

COMBUSTIBLE

CONSTRUCTION

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY 

COMBUSTIBLE

CONSTRUCTION

Содержание 51-05 Largo

Страница 1: ... left burning unattended it may cause damage or serious injury WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any ot...

Страница 2: ...D LOCAL CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN YOUR LOCALITY BEFORE INSTALLATION Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc CAUTION INSTALLATION MODIFICATION AND REPAIR MUST BE DONE BY A CERTIFIED PROFESSIONAL TECHNICIAN or LICE...

Страница 3: ...SSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED G SAFETY NOTE An external on off valve in the gas line is required for safety when your Outdoor Fire Pit is not in use It also provides for convenient maintenance and repair If the Outdoor Fire Pit is connected to Natural Gas its main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system...

Страница 4: ...d by O W Lee Company 1822 E Francis Street Ontario IMPORTANT SAFETY INFORMATION A YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE AREA OF THIS APPLIANCE OPERATING INSTRUCTIONS DO NOT sit or place any part of the body or combustible materials on the Fire Pit surround Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid bur...

Страница 5: ...ructed and marked in accordance with the U S Department of Transportation D O T Specifications for LP Gas Cylinders or the Standard for Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Commission CAN CSA B339 as applicable Use propane cylinders approved for your area such as Blue Rhino or AmeriGas with this appliance Other cylinders may be acceptable for use with the appliance...

Страница 6: ...3 On Off Control Knob 4 Brass Replacement Valve 5 Whisper Quiet Flex Line 22 6 Brass Fitting 7 Orifice Propane 8 Propane to Natural Gas Conversion Kit 9 Natural Gas to Propane Conversion Kit Approved Media 10 Lava Granules 3 8 11 Pebble Fire Glass Kit Size 3 3 4 9 19mm 12 Tumbled Fire Glass Kit Size 3 3 8 9 12 mm 13 Ceramic Rock Kit with Lava Granules 14 Ceramic Sphere Kit with Lava Granules 15 Mi...

Страница 7: ...er support Taper from the top of the burner towards the width edge Figure 2 Pour the first bag of the glass media into the burner support Pour the glass gem tumbled glass media into the Outdoor Fire Pit so that the burner is completely covered See Figure 1 2 and 3 GEM MIRRORED AND TUMBLED GLASS MEDIA PLACEMENT A Carefully inspect the carton for shipping damage If any parts are missing or damaged c...

Страница 8: ... FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Page 8 Ceramic Sphere Placement See Figure 1 2 3 and 4 Figure 1 Pour the lava granules into the burner support Figure 2 Place the larger rocks...

Страница 9: ...ll a qualified professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFOIRMATION...

Страница 10: ...equirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that the air intake holes are closed Figure 2 For Propane gas remove the air shutter so that the air intake holes are open Figure 1 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE THE FIELD CONVERSION...