background image

TAKE READINGS

STEP 17

Remove the patch cable from the detector port on the WaveTester, and bring both units to the opposite 

ends of the link under test.

STEP 18

Connect the WaveTester and Dual OWL to the link under test as shown in Figure 5 below.

STEP 19

Press 

8

/AUTO

 several times until the WaveTester is set to 850nm.

STEP 20

Press 

<SAVE> 

on the WaveTester to store the reading for the current fiber under test.

STEP 21

Disconnect the patch cables from both ends of the patch panel and move to the next port on the patch 

panel.

STEP 22

Repeat steps 20 and 21 for each fiber in the cable under test until all fibers have been tested at 850nm.

STEP 23

For  testing  1300nm,  again  connect  to  the  first  fiber  under  test,  except  this  time  use  the  mandrel-

wrapped patch cable connected to the 1300nm port.

STEP 24

Press 

8

/AUTO

  several times until the WaveTester is set to 1300nm.

STEP 25

Press 

<SAVE> 

on the WaveTester to store the reading for the current fiber under test.

STEP 26

Disconnect the patch cables from both ends of the patch panel and move to the next port on the patch 

panel.

STEP 27

Repeat steps 25 and 26 for each fiber in the cable under test until all fibers have been tested at 1300nm.

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

FIGURE 5

Taking

Readings

dB

2.00

-

850

nm

 LIGHT SOURCE CONNECTOR 

PORT NOTES:

– CONNECTOR TYPE MAY VARY
– DO NOT INSERT ANGLED 

PHYSICAL CONTACT (APC) 
CONNECTOR

Содержание KIT-WT-D2stKIT-WT-D2sc

Страница 1: ...one 262 473 0643 Internet OWL INC COM Revision 1 1 26009 WaveTester Series Test Kits Certification Testing Quick Reference Guide For part numbers KIT WT D2st KIT WT D2sc e C s i h o W i c e e h i T n O s p e i t r i c o a t l a r F o i b b e a r L T h e t s g t n E e l q e u v i p a m W e l n a t c i t p O OWL Optical Wavelength Laboratories ...

Страница 2: ... or fail by Complete understanding of each of these issues is critical for performing proper fiber optic tests GETTING STARTED Thank you for your purchase of this OWL certification test kit Included in this kit is a WaveTester optical power meter and a WaveSource multimode fiber optic light source This quick reference guide will assist you in setting up your test kit for a standards based certific...

Страница 3: ...e EQUIPMENT PORTS Figure 2 shows the ports used during this procedure These ports may vary depending upon the model of equipment VERIFY PROPER OPERATION OF THE EQUIPMENT STEP 1 Connect the power meter and light source together with the first patch cable as shown in Figure 3 STEP 2 Power on the light source STEP 3 Power on the WaveTester STEP 4 Press 8 AUTO several times until the wavelength is set...

Страница 4: ... verified continue on to the next step SET REFERENCE STEP 13 Press and hold the UNITS ZERO button on the WaveTester to set the reference for 850nm The WaveTester display should change to show readings in dB and the power reading should be approximately 0 00 dB This means that the meter and light source have been successfully zeroed at 850nm NOTE if you are also testing at 1300nm you will need to c...

Страница 5: ...t until all fibers have been tested at 850nm STEP 23 For testing 1300nm again connect to the first fiber under test except this time use the mandrel wrapped patch cable connected to the 1300nm port STEP 24 Press 8 AUTO several times until the WaveTester is set to 1300nm STEP 25 Press SAVE on the WaveTester to store the reading for the current fiber under test STEP 26 Disconnect the patch cables fr...