background image

Quick Reference Guide
WaveTester Series
Firmware Version 2.56

Optical Wavelength Laboratories (OWL)

N9623 West US Hwy 12

Whitewater, WI 53190

Phone: 262-473-0643

Internet: OWL-INC.COM

Revision 1.1

26009

WaveTester Series Test Kits

Certification Testing

Quick Reference Guide

For part numbers:

KIT-WT-D2st

KIT-WT-D2sc

e

 C

s i

h

o

W  

ic

e

e

h

 i

T

n

 -

 

 

O

s

p

ei

t

r

ic

o

a

t

l

a

 

r

F

o

ib

b

e

a

r

L

 

 

T

h

e

t

s

g

n

E

e

l

q

e

u

v

ip

a

m

W

 

e

l

n

a

t

c

 

i

-

t

 

p

O

OWL

Optical Wavelength Laboratories

Содержание KIT-WT-D2stKIT-WT-D2sc

Страница 1: ...one 262 473 0643 Internet OWL INC COM Revision 1 1 26009 WaveTester Series Test Kits Certification Testing Quick Reference Guide For part numbers KIT WT D2st KIT WT D2sc e C s i h o W i c e e h i T n O s p e i t r i c o a t l a r F o i b b e a r L T h e t s g t n E e l q e u v i p a m W e l n a t c i t p O OWL Optical Wavelength Laboratories ...

Страница 2: ... or fail by Complete understanding of each of these issues is critical for performing proper fiber optic tests GETTING STARTED Thank you for your purchase of this OWL certification test kit Included in this kit is a WaveTester optical power meter and a WaveSource multimode fiber optic light source This quick reference guide will assist you in setting up your test kit for a standards based certific...

Страница 3: ...e EQUIPMENT PORTS Figure 2 shows the ports used during this procedure These ports may vary depending upon the model of equipment VERIFY PROPER OPERATION OF THE EQUIPMENT STEP 1 Connect the power meter and light source together with the first patch cable as shown in Figure 3 STEP 2 Power on the light source STEP 3 Power on the WaveTester STEP 4 Press 8 AUTO several times until the wavelength is set...

Страница 4: ... verified continue on to the next step SET REFERENCE STEP 13 Press and hold the UNITS ZERO button on the WaveTester to set the reference for 850nm The WaveTester display should change to show readings in dB and the power reading should be approximately 0 00 dB This means that the meter and light source have been successfully zeroed at 850nm NOTE if you are also testing at 1300nm you will need to c...

Страница 5: ...t until all fibers have been tested at 850nm STEP 23 For testing 1300nm again connect to the first fiber under test except this time use the mandrel wrapped patch cable connected to the 1300nm port STEP 24 Press 8 AUTO several times until the WaveTester is set to 1300nm STEP 25 Press SAVE on the WaveTester to store the reading for the current fiber under test STEP 26 Disconnect the patch cables fr...

Отзывы: