background image

© 2 Save Energy Limited 2013 

 

 

 

 

1

Heating Control Room Sensor 

[RBT-3C or RBH-3C]

 

Installation Instructions

Room Sensor to replace existing wired room thermostat. Alternatively can be paired to 

optional Relay Unit to allow wireless connection to the boiler / wiring centre location. 

Support for up to 4 separate heating zones. Provides programmer / time clock functionality. 

Requires Network OWL to operate.

Backplate

Room Sensor

IN THE BOX:

2 x AAA 

alkaline battery

Safety Cover

Содержание Intuition RBT-3C

Страница 1: ...ng wired room thermostat Alternatively can be paired to optional Relay Unit to allow wireless connection to the boiler wiring centre location Support for up to 4 separate heating zones Provides programmer time clock functionality Requires Network OWL to operate Backplate Room Sensor IN THE BOX 2 x AAA alkaline battery Safety Cover ...

Страница 2: ...functionality Basic day to day user operation changes can be made using the three buttons Addition ally there is comprehensive yet intuitive and easy to use control via the OWL Intuition web dashboard Accessible from any Internet connected computer anywhere in the World iPhone and Android smartphone apps are also available for free download It is recommended that this product is installed by a sui...

Страница 3: ...o boiler and Wireless connection to boiler when paired to Relay Unit RMx 6C Multi Heating Zone Control A single OWL Intuition system can support up to 4 Room Sensors one for each heating zone in either a wired and or wireless configuration paired to Relay Units Additionally a single Relay Unit can be paired to multiple 8 Room Sensors and optional Tank Sensors for Hot Water control This flexibility...

Страница 4: ...ck that it is powered up and connected to the OWL servers the top green LED should be flashing in a triple blip pattern IMPORTANT Please upgrade the Network OWL firmware 1 It is essential that the Network OWL is running the latest released version of firmware available at least Version 2 2 Please log in to the OWL Intuition web dashboard at https www owlintuition com this is a secure connection 2 ...

Страница 5: ... LEDs on the Room Sen sor will stop flashing indicating that it is now paired to the Network OWL c Now wait until the Network OWL is connected to the OWL servers the top green LED should be flashing in a triple blip pattern d Log in to the OWL Intuition account at https www owlintuition com this is a secure connection You will then see the OWL Intuition web dashboard e Soon a message box will pop ...

Страница 6: ...settings by clicking on the gear wheels icon on the grey Heat ing widget title bar 4 Configure Time Clock The Heating Time Clock defines the periods during which the home is automatically heated and to what temperature These periods are called Comfort Periods OWL In tuition will intelligently calculate what time to switch the boiler on and off to maintain the target temperature for the whole of th...

Страница 7: ... 2 Save Energy Limited 2013 7 OWL Intuition Web Dashboard Heating and Time Clock widgets ...

Страница 8: ...tails within the Edit box as required then click on the Tick icon to update the table d To add a new line simply fill in the Add box with the required details and click on the Tick icon e When you are happy with your changes you can use the Copy Current Day feature to quickly duplicate to other days Preset Heating Comfort Time Clock Settings Monday to Friday Start Time End Time Temperature 07 00 0...

Страница 9: ... OWL by clicking on the Save To Network OWL button 5 Pair Room Sensor with Relay Unit Intuition cw wireless installations only If this Room Sensor is being installed for a wireless connection to an OWL Intuition Relay Unit RMx 6C then please follow the Relay Unit Installation Instructions sup plied with that device ...

Страница 10: ...ion location you should now check the signal strength icon shown on the web dashboard Heat ing widget The signal should be at least 2 bars and preferably more Try moving the Network OWL closer to the Room Sensor if you have a signal strength problem 2 Ensure there will be enough space to allow easy screwdriver access to the two cap tive screws located at the base of the backplate 3 Electrical Conn...

Страница 11: ...External Programmer Connections LSupply LReturn NSupply N L Remove Link PLEASE NOTE The battery powered Room Sensor has a safety switch fitted and will ONLY work correctly with the backplate supplied This backplate operates the safety switch when correctly fitted Live Switched Live Typical OWL Intuition c Wired Room Sensor Installation ...

Страница 12: ...e wall then secure the plate into position The slots in the backplate will compensate for minor misalignment of the fixings c Wiring All necessary electrical connections should now be made The Room Sensor is double insulated and does not require an earth connection An earth connection block is provided on the backplate for terminating any cable earth conductors Earth continuity must be maintained ...

Страница 13: ...erminals 5 Complete the installation by mounting the Room Sensor to the backplate To do this engage the Room Sensor on the lugs at the top of the backplate then carefully swing the Room Sensor down and push it carefully back into its plug in terminal connectors Locate over the captive screws at the base of the backplate and tighten them so that the Room Sensor is locked into position 6 Existing Pr...

Страница 14: ...cument to the householder and direct them to the Heating Hot Water Control User Manual available for download by click ing on Support Manuals on the web dashboard lower right Terminal Description N Neutral Not used may be used to park unused neutral wire L Live Not used may be used to park unused live wire 1 Common terminal of Room Sensor latching relay 2 Not used 3 Heat Satisfied Normally closed ...

Страница 15: ...ng all 3 buttons together for a minimum of 4 seconds The 3 LEDs will start flashing indicating that it is in pairing mode If the Room Sensor is already paired to a Relay Unit pressing the 3 buttons will delete that pairing Refer to Relay Unit Installation Instructions for further information Safety Switch The Room Sensor is fitted with a safety switch that is automatically activated when the front...

Страница 16: ... Energy Limited 2013 BEFORE Typical Existing Wired Room Thermostat Installation Programmer Timer 19 30 Room Thermostat Room Thermostat typically located in Hall or Lounge Existing wiring Boiler or Wiring Centre ...

Страница 17: ...omfort Standby Away OWL Intuition Room Sensor RBx 3C Room Sensor typically located in Hall or Lounge Existing wiring Boiler or Wiring Centre Broadband Router Network OWL OWL Intuition Wireless Pairing OWL Intuition supports up to 4 heating zones each with a wired or wireless Room Sensor If required along with any Tank Sensors they can all be paired to a single Relay Unit to provide a consolidated ...

Страница 18: ...rmostat Installation Wireless Relay Unit Programmer Timer 19 30 Wireless Room Thermostat Room Thermostat typically located in Hall or Lounge Wireless Relay Unit typically located next to Boiler or Wiring Centre Existing wiring with mains power feed Boiler or Wiring Centre ...

Страница 19: ...ammer Timer and link inputs Option 2 Retain existing Programmer Timer and program to always on Comfort Standby Away OWL Intuition Relay Unit RMx 6C Mains powered Relay Unit typically located next to Boiler or Wiring Centre Comfort Standby Away OWL Intuition Room Sensor Boiler or Wiring Centre Existing wiring with mains power feed RBx 3C Room Sensor typically located in Hall or Lounge ...

Страница 20: ...nit in water or other liquids If you spill liquid over it dry it immediately with a soft cloth Do not use or store the product in conditions that could adversely affect the product such as rain snow desert and magnetic fields Do not subject the product to excessive force shock dust temperature or humidity Keep the product away from heat sources radiators stoves heaters etc Do not use the product i...

Страница 21: ...ocal waste disposal regulations CARING FOR YOUR PRODUCT Before cleaning remove the Room Sensor from the backplate and remove the batteries Use a lightly dampened cloth Do not use liquid or aerosol cleaning agents benzene thinners abrasive or corrosive materials Do not scratch hard objects against the product Do not leave discharged batteries in the product COMPLIANCE The CE marking certifies that ...

Страница 22: ...lful damage misuse or failure to follow product or safety instructions If you return any equipment as faulty 2 Save Energy Limited reserves the right to test the equipment and if found to be in perfect working order to return it to you In this event 2 Save Energy Limited reserves the right to charge for any testing or postage costs incurred This does not affect your legal rights relating to equipm...

Страница 23: ...ower source 2 x 1 5V Alkaline AAA batteries Temperature accuracy typical RBT 3C 0 5 C Temperature accuracy typical RBH 3C 0 2 C Humidity accuracy typical RBH 3C 1 8 RH Latching relay voltage rating 230V a c 10 50 60Hz Maximum Switching Current 8A Latching relay contacts rating Resistive Load 8A 250V a c power factor Ø1 Latching relay contacts rating Inductive Load 3 5A 250V a c power factor Ø0 4 O...

Страница 24: ...sure you state your Network OWL MAC ID 2 Save Energy Limited operate a policy of continuous development and improvement therefore the content of this document is subject to change without notice Issue 2 RBT 3C RBH 3C Installation Manual For details on using your new OWL Intuition heating controls please download the Heating Hot Water Controls User Manual document by clicking on Support Manuals web...