Intended use

2.

Intended use

The  water  to  be  filtered  must  be  of

drinking water quality!
Do  not  use  with  water  that  is  microbio-

logically  unsafe  or  of  unknown  quality

without  adequate  disinfection  before  or

after the system.
Systems certified for cyst reduction may be
used on disinfected waters that may contain
filterable cysts.
It is absolutely essential that the local distri-
butor be consulted before using this filter on
water of a different quality, respectively water
containing additives.
This   Mycare  water  filter  is  suitable  for
use in cold drinking water applications up to
a  maximum  water  temperature  of  30 °C
(86 °F).
The  installation  and  operation  of  the
Mycare  water  filter   is  to be  carried   out
in accordance with all rules and regulations
relevant and valid in the country of operation.
In  addition  to  this,  all  valid  regulations
governing health and safety in the country of
use are to be adhered to at all times.

The  Mycare   water  filter  may  be  used
only as described in these operating instruc-
tions,  any  further  application  is  to  be
deemed  non-compliant  with  the  safety
requirements  indicated  herein  which  may
result in a higher hazard risk to persons and
property.
The manufacturer / supplier cannot be held
liable for any damages resulting from such
use. Such usage is carried out at the user's
full risk. The intended use also includes the
observance of the operating instructions.
Please  consult  with  our  customer  service
department before using this water filter for
any applications other than the ones stipu-
lated in this manual.
The  Mycare  water   filter  may  only  be
used in a technically correct condition, free
from defects and in accordance with health
and safety regulations!
Any functional defects are to be reported

immediately!

Содержание Mycare MP50

Страница 1: ...and safety information carefully before installing and putting the unit into service These must always be handed to the owner user Installation and operating instructions OWA Mycare MP50 Point of use...

Страница 2: ...suitable for use in COLD water drinking applica tions up to a maximum water tempera ture of 30 C 86 F The point of use water filter operates on the basis of a 2 stage function principle 1st stage acti...

Страница 3: ...transmit heat back through its respective plumbing Always ensure that this product is installed so that that the water tempe rature never exceeds a maximum of 30 C 86 F for all applications If in doub...

Страница 4: ...formation on the Mycare so that it can be used in a safe economical and appropriate manner It contains fundamental information which must be observed during installation opera tion and maintenance Str...

Страница 5: ...the general danger symbols given in this manual may result in the following risks among others failure of important functions of this filter danger to persons due to electrical and mechanical effects...

Страница 6: ...id in the country of operation In addition to this all valid regulations governing health and safety in the country of use are to be adhered to at all times The Mycare water filter may be used only as...

Страница 7: ...r the Mycare water filter is between 103 kPa 15 psi to 345 kPa 50 psi Under these pressure ranges the Mycare MP 50 water filter works most effectively 2 2 Information on hazard risks 2 2 1 Electrical...

Страница 8: ...ty as close as possible to the point of use see fig 4 ATTENTION The water supply is to be turned off shut off before installation and may only be reopened once installation is fully completed Failure...

Страница 9: ...he Mycare water filter can be installed in all standard commercial drinking water pipes Please shut down the incoming water supply before Installation is started Pay attention to the flow direction se...

Страница 10: ...nce all the air has been vented see fig 7 7 Keep on flushing with at least 3 liters of water i e 10 minutes at rated flow or until the effluent is clear 8 Turn the faucet off 9 Set up the indicator fo...

Страница 11: ...1 1 Mycare MP 50 Installation Fig 8 Installation cold water tubing tubing water filter wall mounting water filter shut off valve shut off valve brackets Shut off valves and tubing by others...

Страница 12: ...icator for the next filter ch ange Move the indicator button on the flange cover to the next filter change require ment filter change every 2 6 months at the latest 7 Check for leaks both immediately...

Страница 13: ...ing or the cartridge with your bare hands 10 Insert the new replacement cartridge in the built in rotary flange and press in up to the limit stop 11 Insert the filter housing into the bayonet opening...

Страница 14: ...es flange cover built in rotary flange replacement cartridge micro filtration filter housing complete Allen key SW 5 used cartridge micro filtration used cartridge activated carbon bleed screw filter...

Страница 15: ...rofiled flange seal is missing assembled wrongly or needs to be replaced every 2 years Check if the profiled flange seal is missing assembled wrongly or needs to be replaced The profiled side of the s...

Страница 16: ...hol spiritus which may damage the unit 8 Warranty and services All products are supplied in accordance with the legal requirements of warranty legislation in their country of use Please note that fail...

Страница 17: ...re min 103 kPa 15 psi Water pressure max 345 kPa 50 psi Cartridge replacement interval 3 months n i m l 2 e t a r w o l F 0 53 US gpm Total capacity per filter cartridge MF 2000 l1 528 US gal AC 2000...

Страница 18: ...Mycare MP 50 8 1 Spare parts MP 50 10 Spare parts MP 50 10 1 2 4 3 B 5 6 7 8 C A A 9...

Страница 19: ...2110040 B Spare parts set Filter hood consisting of pos 5 6 7 8 1 2110102 C Spare parts set Wall mounting bracket 1 2110065 2 MP 50 r e v o c e g n a l F 1 1 w e r c s d a e h t l o B 2 3 Replacement...

Страница 20: ...ts are reserved for modifications as a result of technical progress or further developments Claims with regard to models or products are excluded 9990112 2015 02 OWA GmbH Postfach P O Box 100831 D 737...

Отзывы: