Date
Serial Number
Model #
COM0568
Work Order #
Orifice Installed
#35 - Liquid Propane
BTU Rating
Orifice Included
NG #26 COM0568CK
Inspector
Air Shutter Sleeve
Included
Leak Test
Gas Type
Liquid Propane
Burn Test
LP 65,000 / NG 65,000
Page 14
FIGURE 1
Casual Fireside Fire Pits Are
Suitable For Installation from
0 - 4,500 ft. Without Modification.
Follow steps 1 – 5 shown above.
THE CONVERSION MUST BE CARRIED OUT
BY A QUALIFIED SERVICE AGENCY, IN
ACCORDANCE WITH THE REQUIREMENTS OF
THE MANUFACTURER, PROVINCIAL OR
TERRITORIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CAN/CGA-
B149.1 OR CAN/CGA-B149.2
INSTALLATION CODES.
After conversion follow Operating Instructions
found on Page 12.
FIGURE 2
After The Unit Is Converted, it Must Be
Tested to Verify the Inlet and Manifold
pressures are as specified on Page 3.
Additionally, a qualified
service agency must
verify that the input rate of the converted
appliance match the rating listed below.
MANUFACTURER'S USE ONLY
QUALITY CHECK
3.
Remove the orifice from the holder (Figure # 2 ) and replace it with the proper sized one for your gas requirement.
Propane requires the smaller orifice.
4.
If you are converting from propane (LP) gas to natural gas, install the air shutter sleeve so that the air intake holes are
closed (Figure #2). For Propane gas, remove the air shutter so that the air intake holes are open (Figure #1). After the
unit is assembled for use, you are required to do a "leak check" by using a liquid
soapy
solution on all connections
before placing the unit in operation.
5.
IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO
CLEARLY INDICATE THE FIELD CONVERSION.
CONVERTING YOUR FIRE PIT TO NATURAL GAS
This Conversion should only be performed by a Qualified Service Technician or Licensed Plumbe
1.
MAKE SURE THAT THE GAS SUPPLY TO THE FIRE PIT (AND ANY NEARBY ELECTRICAL
SOURCES/APPLIANCES) ARE SHUT OFF.
2.
Carefully detach the flex line connector hose attached to the orifice holder (Figure # 1) and unscrew the orifice holder
from the burner pipe (Figures #1 and # 2).
Orifice
Orifice Holder
Burner
When converting to natural gas, the air shutter
sleeve MUST be installed over the burner pipe.
Flex Line
Connector Hose
Burner
Orifice Holder
Flex Line
Connector Hose
Orifice
Air Intake hole open for LP Gas