Table of Contents

Cover - Important Safety Information

1

Important Safety Information and

Minimum Clearances to Combustibles

2

Pre-Installation & Preparation Guidelines

3

Important Safety Information

4

Installation Information

Connecting the Gas to the Fire Pit

5

Propane Tank Information

6

Media Placement and Replacement Parts List

Certified Media List / Protective Screen Media Clearance

7

Gem, Mirrored, Crushed Glass and Lava Rock Installation

8

Ceramic Logs and Rock Media Installation

9

Trouble Shooting Guide

10

Warranty Information

11

Operation Instructions

Lighting Instructions

12

Proposition 65 Public Warning

13

Conversion to a Different Gas Type

14

A.

B.

C.

D.

E.

OUTDOOR FIRE PIT - TABLE OF CONTENTS

IMPORTANT SAFETY INFORMATION

READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.

If not installed and used correctly per these instructions,

this product can cause serious injury, death, and or property damage and may void the warranty.

CAUTION

:  FIXED PIPING GAS SUPPLY INSTALLATION, AND REPAIRS MUST BE DONE BY

A CERTIFIED PROFESSIONAL TECHNICIAN or LICENSED PLUMBER.

Be sure you understand all safety precautions and warnings contained in this manual.

If you have any questions, please contact O.W. Lee at (800) 776-9533

Figure 1

IMPROPER INSTALLATION OR USE OF YOUR OUTDOOR FIRE PIT CAN CAUSE SERIOUS INJURY,  DEATH, AND OR 
PROPERTY DAMAGE FROM FIRE, BURNS, EXPLOSIONS OR CARBON MONOXIDE POISONING.

Clearances to Combustible Construction:

Sidewalls:  60”  (1.5 m) from center of unit (Figure 1)
Ceiling:  60” (1.5 m) from top of unit to ceiling or overhang
Flooring:  0” – Can be installed on deck, slab, floor, etc.

The dimensions shown in Figure 1 are MINIMUM
CLEARANCES to maintain when you install this Outdoor Fire 
Pit.  THERE MUST BE AT LEAST 60” of clearance from the 
center of the unit  to any combustible sidewalls, ceilings, or 
material.

Page 2

CHECK STATE AND LOCAL BUILDING CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN
YOUR LOCALITY BEFORE INSTALLATION.

FOR OUTDOOR USE ONLY.  THIS UNIT MUST BE INSTALLED AT LEAST 60” FROM CENTER OF BURNER TO ANY 
COMBUSTIBLE WALLS, CEILINGS, OR MATERIAL.

WHEN SHUTTING OFF THE UNIT — BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FULLY OFF 
POSITION ON THE FIRE PIT and CLOSE THE VALVE ON THE PROPANE TANK or NATURAL GAS SUPPLY LINE.

WARNING:  CARBON MONOXIDE POISONING MAY LEAD TO DEATH. 

 DO NOT MODIFY THIS OUTDOOR FIRE PIT

OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL.

MINIMUM CLEARANCE TO COMBUSTIBLES

NOTE

MINIMUM OF 60” (1.5 m) CLEARANCE ABOVE THE 

OUTDOOR FIRE PIT IF INSTALLED UNDER CEILING OR 

OVERHANG 

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY

COMBUSTIBLE

CONSTRUCTION

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY 

COMBUSTIBLE

CONSTRUCTION

Содержание 5114-42BTC

Страница 1: ...ld result in fire or explosion which could cause personal injury death or property damage 3 If odor continues leave the area immediately 4 After leaving the area call your gas supplier or fire department 2 Extinguish any open flame READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT If the information in this manual is not followed exactly a fire or explosion may result causing p...

Страница 2: ...e 1 IMPROPER INSTALLATION OR USE OF YOUR OUTDOOR FIRE PIT CAN CAUSE SERIOUS INJURY DEATH AND OR PROPERTY DAMAGE FROM FIRE BURNS EXPLOSIONS OR CARBON MONOXIDE POISONING Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are ...

Страница 3: ...nd to use may not be the same that your fire pit was setup for or is stated on your outdoor rating plate THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS If the gas supply is different or you wish to change to Natural Gas you MUST have the Fire Pit Converted directions to convert can be found on page 14 to the gas type you intend to use Any gas type conversion should be performed by a qualifi...

Страница 4: ...ing your FIRE PIT if you smell a rotten egg odor or have headaches nausea or dizziness G WARNING DO NOT throw trash paper plastics or any other flammable materials into your Fire Pit WARNING DO NOT leave fire pit lit when unattended H DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control ...

Страница 5: ...339 as applicable Use cylinders approved for your area such as Blue Rhino or AmeriGas with this appliance Other cylinders may be acceptable for use with the appliance provided they can be mounted to the appliance using the cylinder retention devise provided See illustration above The LP Gas Cylinder to be used must be provided with a listed overfilling prevention device OPD and with a cylinder con...

Страница 6: ...in cylinder is purged of trapped air prior to first filling Be certain not to over fill the cylinder Be certain cylinder requalification date is checked Do not use store or transport cylinder where it would be exposed to high temperatures Relief valve may open allowing a large amount of flammable gas to escape When transporting keep cylinder secured in an upright position with cylinder valve turne...

Страница 7: ...isper Quiet Flex Line 22 6 Brass Fitting 7 Propane Orifice 8 Natural Gas Conversion Kit 09 Protective Mesh Screen 10 Thermocouple 11 Pebble Glass Kit Size 3 4 1 2 9 19mm 12 Crushed Fire Glass Kit Size 1 2 3 4 12 20 mm 13 Mirrored Glass Kit Size 1 4 6 35mm 14 Lava Granules 3 8 15 Ceramic Rock Kit with Lava Granules 16 Ceramic Log Kit with Lava Granules PROTECTIVE SCREEN MEDIA PLACEMENT REPLACEMENT ...

Страница 8: ...l bag of lava granules onto the burner support Spread the media evenly covering the burner Page 8 CAUTION BURN HAZARD GEM MIRRORED and CRUSHED GLASS and LAVA GRANULES WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIA...

Страница 9: ...uld cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lighting and using the fire pit CERAMIC ROCK MEDIA PLACEMENT Figure 1 Place the largest log diagonally centered of the burner Figure 2 Please the larger three logs as desired using the largest log as the support Figure 3 Place the balance of the logs as desired Make sure to lea...

Страница 10: ...fferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctly when finished for proper fire pit operation and safety This is a common problem when the fire pit has not been used for an extended period of time Low or Excessive Flame Using Natural Gas The water...

Страница 11: ...tions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor fire pit burner found to be defective during this warranty period Regular maintenance must be exercised as set forth in the owner s manual For more information go to www owlee com Items Not Covered ...

Страница 12: ... the Outdoor Fire Pit area for a rotten egg smell Be sure to smell close to the floor because propane gas is heavier than air and will settle on the floor IF YOU SMELL A ROTTEN EGG SMELL IMMEDIATELY 1 Shut off the gas supply to the appliance 2 If odor continues keep away from the appliance and immediately call your gas supplier or the fire dept Use only your hand to push in and turn the gas contro...

Страница 13: ...a for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals These chemicals include carbon monoxide benzene formaldehyde and acetaldehyde All chemicals known to the State to cause cancer and or birth defects The Company encourages all of its customers to use ...

Страница 14: ... After The Unit Is Converted it Must Be Tested to Verify the Inlet and Manifold pressures are as specified on Page 3 Additionally a qualified service agency must verify that the input rate of the converted appliance match the rating listed below Follow steps 1 5 shown above THE CONVERSION MUST BE CARRIED OUT BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER PROV...

Страница 15: ...les instructions françaises INSTALLATEUR Laissez ce manuel avec l appareil CONSOMMATEUR Conservez ce manuel pour référence ultérieure DANGER DE MONOXYDE DE CARBONE Cet appareil peut produire du monoxyde de carbone qui n a pas d odeur Son utilisation dans un espace clos peut vous tuer N utilisez jamais cet appareil dans un espace clos tel qu une caravane une tente une voiture ou à la maison 4 Après...

Страница 16: ...TION INCORRECTE OU UTILISÉE DE VOTRE PUITS D INCENDIE EXTÉRIEUR PEUT CAUSER DES BLESSURES GRAVES LA MORT OU DES DOMMAGES À LA PROPRIÉTÉ EN CAS D INCENDIE DE BRÛLURES D EXPLOSIONS OU D EMPOISONNEMENT AU MONOXYDE DE CARBONE Parois 60 1 5 m du centre de l unité Figure 1 Plafond 60 1 5 m de haut de l unité au plafond ou faux Revêtement de sol 0 Peut être installé sur le pont la dalle le plancher etc L...

Страница 17: ...tre dimensionné de sorte à fournir la pression minimale d admission au débit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fireside foyers sont adaptés pour l installation à partir de 0 4500 m sans modification H Si le foyer extérieur est raccordé au gaz naturel sa valve principale de gaz doit être déconnectée du système de tuyauterie d...

Страница 18: ...t les réparations doivent être effectuées par un technicien qualifié L appareil doit être inspecté avant utilisation et au moins une fois par an par un technicien qualifié Un nettoyage plus fréquent peut être nécessaire si nécessaire Il est impératif que le compartiment de commande les brûleurs et les passages d air de circulation de l appareil restent propres Le brûleur doit être remplacé avant l...

Страница 19: ...usure excessive ou si le tuyau est endommagé Le tuyau de remplacement doit être spécifié par le fabricant 1 2 La ou les bouteilles de gaz LP à utiliser doivent être construites et marquées conformément aux directives du département américain de la Transport D O T Spécifications des bouteilles de gaz LP ou norme sur les bouteilles sphères et tubes pour le transport des marchandises dangereuses et C...

Страница 20: ...ez vous que la date de requalification des bouteilles est vérifiée Assurez vous que l évent du régulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit où elle serait exposée à des températures élevées La soupape de décharge peut s ouvrir et permettre à une grande quantité de gaz inflammable de s échapper Lors du transport garder le cylindre bien en...

Страница 21: ...és comme indiqué ci dessus Page 7 LISTE DES PIÈCES Pièces de rechange disponibles chez votre revendeur local LES PIÈCES DE REMPLACEMENT ET LES SUPPORTS SONT DISPONIBLES CHEZ VOTRE CONCESSIONNAIRE LOCAL nº 1 X Burner en acier inoxydable nº 2 Tuyau de régulateur de propane de 4 nº 3 Bouton de contrôle On Off marche arrêt nº 4 Bras De Contrôle Soupape nº 5 Ligne Flex 22 Chuchotement Silencieux nº 6 C...

Страница 22: ...tera chaud pendant un certain temps après utilisation VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQUÉE POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MATÉRIAU POUR MAINTENIR LA DISPOSITION APPROPRIÉE UTILISEZ LA CHALEUR GANTS RÉSISTANTS OU PERMETTRE AU MATÉRIAU LE TEMPS DE REFROIDIR AVANT DE LE MANIPULER ATTENTION les granules de lave utilisées dans un foyer sont po...

Страница 23: ... DISPOSITION APPROPRIÉE UTILISEZ LA CHALEUR GANTS RÉSISTANTS OU PERMETTRE AU MATÉRIEL UN TEMPS APPROPRIÉ DE SE REFROIDIR AVANT MANIPULATION ATTENTION les granules de lave utilisées dans un foyer sont poreuses et chauffées à la température de fonctionnement normale peut provoquer une expansion des gaz piégés ou de l humidité et provoquer un éclatement et un lancement à pourrait causer des blessures...

Страница 24: ... petit fil dans le venturi et orifices des trous pour dégager le passage libre des toiles d araignées ou d autres débris Assurez vous de tout remettre correctement lorsque vous avez terminé pour le fonctionnement du foyer adéquat et la sécurité Ceci est un problème commun lorsque le foyer n a pas été utilisé pendant une longue période de temps Flamme faible ou excessive Utilisation de gaz naturel ...

Страница 25: ... Parties Pit Fire O W Lee offre une garantie limitée de deux 2 ans sur tous les composants du brûleur en utilisation normale et appropriée entretien OW Lee sera à l usine de réparer ou de remplacer tout brûleur extérieur foyer trouvé défectueux pendant cette période de garantie Un entretien régulier doit être exercé selon dans le manuel du propriétaire Pour plus d informations consultez www owlee ...

Страница 26: ...l et pour remplacer toute pièce du système de contrôle et tout contrôle de gaz qui aurait été sous l eau INSTRUCTIONS D ÉCLAIRAGE STOP LIRE LES INFORMATIONS DE SÉCURITÉ CI DESSUS 1 Assurez vous que la soupape de commande du foyer et la soupape du réservoir de propane sont fermées 2 Attendez au moins 5 minutes que le gaz se vide Enfoncez légèrement le bouton de réglage manuel du gaz et tournez dans...

Страница 27: ...e répertorié de la Proposition 65 La combustion de propane dans des appareils tels que des poêles ou des systèmes de chauffage et des véhicules utilisant du propane crée des produits chimiques nocifs Ces produits chimiques comprennent le monoxyde de carbone le benzène le formaldéhyde et l acétaldéhyde Tous les produits chimiques reconnus par l État comme pouvant causer le cancer et ou des anomalie...

Страница 28: ...uide sur toutes les connexions avant de mettre l unité en marche 5 IL EST NÉCESSAIRE DE POSER L ÉTIQUETTE OU LA PLAQUE SIGNALÉTIQUE INCLUSE DANS LE KIT DE CONVERSION AFIN D INDIQUER CLAIREMENT LA CONVERSION FAITE SUR PLACE LP 60 000 NG 60 000 FIGURE 1 Casual Fireside foyers sont adaptés pour l installation à partir de 0 4500 m sans modification Suivez les étapes 1 à 5 ci dessus LA CONVERSION DOIT ...

Отзывы: