7. Operator/Control Panel

The ULTAMUS RAID 1200 front panel incorporates an 
Operator’s (OPS) Panel with four LEDs (

Figure 8

). The 

OPS Panel provides a high-level indication of the 
operation of the appliance. 

NOTE:

The OPS Panel is an integral part of the chassis assembly 

and can only be replaced with a replacement chassis. Chassis 
replacement should only be performed by trained personnel.

Figure 8.  Operator’s Panel LEDs

8. Additional Information

The ULTAMUS RAID 1200 appliance is preconfigured 
with default IP addresses:

10.1.1.5 for the lower RAID Controller (Controller 0)

10.1.1.6 for the upper RAID Controller (Controller 1)

10.1.1.7 if an error is detected

255.0.0.0 for the subnet mask

IMPORTANT:  Do not connect the unit to a DHCP network 
before establishing the IP addresses with the host.

Launching 

ULTAMUS RAID manager

1.

In your Web browser on the management system, enter 
the applicable IP address to access the array, in the 
following format (example):

http://10.1.1.5:9292

2.

Use the following default login (case-sensitive):
Logon:

admin

Password: 

password

3.

Begin the configuration process.

For detailed instructions on how to connect the ULTAMUS RAID 1200 Storage Appliance to a network, and all other 
appliance configuration information, see the 

ULTAMUS RAID 1200 Setup Guide

 found on the 

ULTAMUS RAID 1200 

Software and Documentation CD

.

All information contained in or disclosed by this document is considered proprietary by Overland Storage. By accepting this material, the recipient agrees that this material and the information contained therein are held in confidence and in trust and will not be

used, reproduced in whole or in part, nor its contents revealed to others, except to meet the purpose for which it was delivered. It is understood that no right is conveyed to reproduce or have reproduced any item herein disclosed without express permission from

Overland Storage. Overland Storage provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Overland Storage may make

improvements or changes in the product(s) or program(s) described in this document at any time. These changes will be incorporated in new editions of this publication.
Overland Storage assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of this document, nor for any problem that might arise from the use of the information in this document.

Table 1:  Operator’s Panel LED Definitions

OPS Panel LEDs

Other LEDs or Alarms

State Description

Power

On

System

Fault 

Logical

Fault 

Box

Identify 

ON

ON

ON

ON

Single beep, two double beeps

Power-On Self Test

ON

OFF

Power On, all functions good

ON

ON

PSU Fault LED or Cooling Fan 
Module Fault LED

Any PSU Fault, Cooling Fan Module Fault, or Over/
Under Temperature Condition

ON

ON

RAID Controller Fault LED on the 
specific controller

A RAID Controller Fault

ON

ON

Drive Fault LED

Drive failure has occurred causing loss of availability or 
redundancy

ON

ON

Array is performing background function such as a 
parity check, initialization, or expansion

ON

Chassis identification mode. When illuminated it 
identifies the specific chassis

Additional Help