Overland Storage REO 4500x Скачать руководство пользователя страница 3

Part Number 10400120-102 06/2007

©2007 Overland Storage, Inc.

W

Page 

of

 4

Figure 7.  Attaching Rear of Rail

Installing the REO 4500x in the Rack

WARNING:  It is recommended that a mechanical 
lifter (or at least two people) be used to prevent 
injury during rack removal and reinsertion.

1.

At the front of the rack, pull out the middle members 
until they lock (click) in the extended position.

2.

Engage the inner members mounted on the appliance 
with the intermediate members protruding from the 
rack, sliding the appliance in until it stops.

3.

Push the white latch on both sides of the inner 
members toward the rack and slide the inner members 
into the intermediate members, sliding the appliance 
all the way into the rack.

4.

Slide the appliance in and out several times to ensure 
that the rail members slide smoothly, the locks engage 
properly, and the appliance does not bind.
If binding occurs, verify that the front and rear flanges 
are mounted in the correct holes, readjusting the slide 
positioning as necessary.

5.

Using the two screws provided, secure the appliance 
flanges to the rack. 

Reinstalling Drives in REO 4500x

Once the appliance is in the rack, reinstall the drives back 
into their original slots.

1.

Position the drive carrier assembly with the release 
button to the right before you slide it into the chassis.

2.

Carefully insert the drive assembly with the lever lifted 
until it completely enters the bay.

3.

Push the lever back in place (

Figure 8

).

4.

Turn the lock on the lever clockwise to secure the drive 
carrier in the chassis.

Figure 8.  Locking Drive Carrier into Place

5.

Repeat these steps for each remaining disk drive 
carrier.

NOTE: To maintain proper airflow and cooling, a disk drive 
or a blank drive carrier must be installed in every slot.

Attaching Cables

All cabling and power connections are located on the rear 
panel of your REO 4500x expansion unit (

Figure 9

). All 

unit cooling exhaust is handled through the rear panel. 

The REO 4500x comes with the following:

InfiniBand-to-MiniSAS cable

MiniSAS-to-MiniSAS cable

Figure 9.  REO 4500x Rear Panel Connections

Locking Latch

1 - SAS Port (In)

2 - SAS Port (Out)

3 - AC Power Connectors

1

2

3