![Overkill Solar 120A 4s 12V BMS Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/overkill-solar/120a-4s-12v-bms/120a-4s-12v-bms_instruction-manual_1662874058.webp)
1
VDD
Red
2
TX (BMS to client)
White
3
RX (client to BMS)
White
4
Ground
Black
Note: The Bluetooth module’s serial interface connector is wired backwards from above. Pins 1 and 4 are
swapped, and pins 2 and 3 are swapped.
Part Numbers:
●
Female housing:
●
Pins for female housing:
●
Male connector, through-hole, vertical: JST
●
Male connector, through-hole, right-angle: JST
D.1.3 BMS Switch Connector
Connector type: JST XH
Pin
Function
Wire color
1
Switch contact #1
Red
2
Switch contact #2
Black
Note: Connect a normally-closed switch to the two wires.
Part Numbers:
●
Female housing:
●
Pins for female housing:
●
Male connector, through-hole, vertical: JST
●
Male connector, through-hole, right-angle: JST