REGTRONIC PX 

6.5  Control unit usage example 

6.5.1  Changing Target dTon temperature 

 
Once you have familiarized yourself with the 
menu  descriptions  in  the  "User  menus" 
section,  you  can  start  making  some 
operational  changes.  The  example  below 
describes  one  such  operational  procedure. 

The  starting  point  here  is  the  "Info"  menu, 
showing  the  current  collector  temperature. 
Objective:  Change  the  parameter  "Target 
dTon"  from  7  K  to  5  K,  using  the 
"Programming" 

menu. 

 

 

 

 

 

 

 

Escape: Exit the "Info" menu 

 

 

 

 

 

 

Page right: Select "Programming" menu 

 

 

 

 

 

 

 

Select "Programming" menu 

In  the  "Programming"  menu,  page  until  the  submenu  "Storage 
tank" is shown. 

 

 

 

 

 

 

Select submenu "Storage tank" 

 

 

 

 

 

 

In the submenu, page until the value "Target dTon" is shown. 

 

 

 

 

Collector 

122

.

F

 

32<-

.

F->153 

 

   

 

 

 

 

 

 

   Flashes

 

12:09:24 

 

 

 

 

 

 

 

 

 

 

                 Flashes 

12:09:24 

 

 

 

 

 

 

 

 

 

 

Storage tank 

149

.

F

 

maximum 

 

 

 

 

 

 

 

 

Storage tank 

[Values]

 

 

 

 

 

 

 

Содержание REGTRONIC PX

Страница 1: ...s Oventrop REGTRONIC PX oventrop Regtronic PX Important Please read the instructions carefully before installing and operating the unit Failure to do so can void product warranty Please keep the instr...

Страница 2: ...MATERIAL DAMAGE AND ENVIRONMENTAL POLLUTION 6 4 UNIT INSTALLATION 7 4 1 OPENING THE UNIT 8 4 2 WALL INSTALLATION 8 5 ELECTRICAL CONNECTIONS OVERVIEW 9 5 1 GENERAL CONNECTION GUIDELINES 10 5 2 115 V C...

Страница 3: ...information User action procedure Inspection check Frequently used abbreviations Abbreviations and symbols are sometimes used to improve legibility in this documentation and on the display of the con...

Страница 4: ...teriors If you wish to use the unit for other purposes please check applicable statutory regulations prior to use 2 3 Unit features The control unit can be used with many types of system Regardless of...

Страница 5: ...ghten the locking screw hand tight Make sure that the mains connection can be interrupted with an external switch The possibility of fatal electric shocks exists on damaged units Only use the unit in...

Страница 6: ...e sensors Only install the temperature sensors in the intended position on the collectors Install the temperature sensors in such a way that good heat transfer is ensured Route the cables to the tempe...

Страница 7: ...e only DANGER Lethal hazard due to electric shocks when working on the electrical system Have all work on the electrical system carried out by qualified specialist personnel only Prior to all work mak...

Страница 8: ...he sides of the cover see picture and then pivoting the cover upwards Continue to pull the cover upwards until it snaps into place This will enable you to easily install and connect up the control uni...

Страница 9: ...y Following all work place the cover onto the casing until it engages and tighten the locking screw hand tight DANGER Lethal hazard due to electric shocks on tearing off connections with flexible cabl...

Страница 10: ...General connection guidelines When connecting all cables strip the cable covering to a length of approx 3 and the wires to a length of approx 4 For flexible cables a strain relief device must be pres...

Страница 11: ...n some layouts the use of radiation sensors and flow transmitters will also be required Inputs 1 to 7 are suitable for temperature sensors Inputs 8 to 10 are universal inputs which can be used for tem...

Страница 12: ...K E Revised 03 2010 REGTRONIC PX 6 OPERATION DISPLAY 6 1 Overview of display and control buttons oventrop Regtronic PX Number Description 1 Screen with graphical icons and 3 line simple text display 2...

Страница 13: ...tion of icons The following table describes the meanings of the various icons used Status display Regulator active Icon rotates if solar circuit pump is switched on Displays active switched outputs Nu...

Страница 14: ...he control buttons have the following functions Button Function Description Up Page up in the menu Change value stepped increase of the value displayed If the button is pressed and held values increas...

Страница 15: ...describes one such operational procedure The starting point here is the Info menu showing the current collector temperature Objective Change the parameter Target dTon from 7 K to 5 K using the Program...

Страница 16: ...ow begins to flash Decrease the value until the chosen value is selected Value continues to flash Select Confirm value or Icon ok flashes Confirm the change Change is applied Leave value as is change...

Страница 17: ...es the switch off temperature Limiting the minimum temperature of the energy source such as for the storage tank releasing energy The function is only switched on once the energy source sensor reaches...

Страница 18: ...rame are identical this time frame will be deactivated that is will not be taken into account Start time of the 3rd time frame for the MFR Stop time of the 3rd time frame for the MFR Time frame is als...

Страница 19: ...s in the menu Make sure that only qualified specialist electricians open and work with the Manual mode Basic setting or System setting menus To make the device as easy as possible to operate all devic...

Страница 20: ...l Operation Manual activation and deactivation of attached pumps valves Notice Changes can compromise system functionality Settings and changes here should only be carried out by technicians System Se...

Страница 21: ...ementary features are shown If values can be reset then they can be reset as follows Select the value you want using buttons and To reset the value use button Confirm message OK using for No or for Ye...

Страница 22: ...tions are optional To use them you will need extra accessories not included with the unit such as a DataStick or modem 9 1 DataStick A DataStick provides a simple way to carry out data exchange betwee...

Страница 23: ...ified as needed using Data logging on the Programming menu Recording interval configuration Selection of simple recording storage medium is written to until full or cyclical recording old data is over...

Страница 24: ...ontrol unit 10 1 Reportable faults Error displayed on screen Possible causes Suggested action flashing Disruption to sensor cable Sensor defective Check cable Check sensor resistance replace sensor if...

Страница 25: ...ply unavailable Switch on or connect up control unit Check fuses for building power supply Fuse inside unit defective Check fuse replace if necessary with new 2A T fuse Check 115 V components for shor...

Страница 26: ...dfos sensor Temperature sensor measuring range PT1000 silicone cable with probe 1 k at 32 F 22 F to 482 F Output 1 6 115V 1A cos 0 7 Output 7 potential free 115V 1A cos 0 7 Fuse protected Fine wire fu...

Страница 27: ...ng and consequential losses and damages Warranty claims must be received by Oventrop Corp within the applicable warranty period and within thirty 30 days from the cause for the claim occurred or was d...

Отзывы: