Instructions for installers
REGTRONIC PC
Instructions for installers 136659383
3
1317ZB009-10B-E, Revised 03/2008
REGTRONIC PC
1 " S
Y S T E M
S
E T T I N G S
"
M E N U
“/
C
H AN G E S
T O T H E S Y S T E M
During normal operation, the "System
Settings"
menu
only
displays
parameters and does not allow them to
be altered. This prevents accidental
changes. To change parameters, this
menu must be selected within one
minute of switching on the unit.
While the system is running, changes
can be made using the System
Settings menu by pressing the top
, bottom
and right-hand
button simultaneously.
Once the user is in the menu, no time
limits apply.
The System Settings menu "locks"
itself automatically one minute after
the unit has been switched on and
one minute after the user has exited
the menu.
The System Settings menu is used to
select the basic schema and the
language, and also to activate or
deactivate the available protective and
ancillary features. The buttons
and
are used to page through
the various submenus. The status –
e.g. "On" or "Off" – is also shown next
to the name of each submenu.
Submenus are selected by using the
button.
Allocation of layout no. to system number: PC0 = 3330, PC1 = 3331, PC2 = 3332,
PC3=3333, PC4=3334
Note:: 3300 is the initial software set!
Example: change system from 3300 to 3331
System sel.
[off]
off
System
3300
on
off
ok
ok
3300
3301
ok
ok
Service
[off]
MultiReg3
[off]