20
4.3 Installation field
Keep existing roof battens as support and fix the additionally required battens according to the dimensional specifications.
If possible, define installation field so that the distance between one side of the collectors and the lateral roof covering is approximately 15
mm. Cut tiles to size for the opposite side.
A
22
31
24
24
18
90
10
0
60
-1
30
15
Installation dimensions [mm]
Number of collectors
Width of collector field
Width of installation field A
1 collector
1,160
1,190
2 collectors
2,325
2,355
3 collectors
3,490
3,520
4 collectors
4,655
4,685
5 collectors
5,820
5,850
Dimensions for installation field and location of battens. Use battens of the same thickness as the existing ones.
Additionally required battens are marked grey (5 pieces); length of battens = A (width installation field)
Width installation field = n x collector width + n – 1 x 5 mm (collector distance) + 2 x 15 mm (distance to the edge).
Outer dimensions of collector (L x W) = 1,930 x 1,160.