LEAK TESTING

WARNING: Before using this outdoor fire pit, make sure you have read, understand and

are following all information provided in the Dangers and Warnings. Failure to follow

those instructions can cause death, serious injury or property damage.

WARNING

DANGER

CAUTION    Strong odours, colds, sinus congestion, etc. may prevent the detection of

propane by smell. Use caution and common sense when testing for leaks.

WHEN TO PERFORM A LEAK TEST:

Never use your fire pit without leak testing all gas connections, hoses and propane tank.

To prevent fire or explosion hazard:

•  DO NOT smoke or permit ignition sources in the area while conducting a leak test.

•  Perform test OUTDOORS in a well-ventilated area that is protected from the wind.

• 

Never perform a leak test with a match or open flame.

• 

Never perform a leak test while the fire pit is in use or while the fire pit is still hot.

• 

After assembling your fire pit and before lighting for the first time, even if purchased fully-assembled.

• 

Every time the LP gas cylinder is refilled, exchanged or if any of the gas components are disconnected 

 

or replaced.

• 

Any time your fire pit has been moved.

• 

At least once per year or if your fire pit has not been used for more than 60 days.

1.  Create a mixture of 50% water and 50% liquid dishwashing soap.
2.  Ensure all control knobs are set to the OFF position.
3.  Turn on the gas at the cylinder valve. Turn the cylinder valve knob counter-clockwise until 

fully opened. If you hear a rushing sound or smell gas, turn the gas off. Tighten any leaking 

connections. If the leak is detected at connection nut and tightening does not stop leak, re-inspect 

propane tank rubber  seal.

4.  Apply the soapy water mixture to the following:
 

A)  Supply tank (cylinder) welds   

 

 

B) Connection nut to tank valve

 

C)  Back side of connection nut to brass nipple  

D) Brass nipple connection into regulator

 

E)  Regulator connections to gas supply hoses  

F) Hose connection to gas manifold

 

G) The full length of gas supply hose 

 

 

H) Tank valve to cylinder

5.  Check each place listed (A-H) for growing bubbles, which indicates a leak. Large leaks may not be 

detected by bubbles but should produce a rushing sound or gas smell.

6. 

Turn off gas supply at cylinder valve.

7.  Turn on control knobs to release gas pressure in hose.
8.  Turn control knobs to OFF position.
9.  Tighten any leaking connections. If leak is detected at connection nut and tightening does not stop 

leak, re-inspect propane tank rubber seal.

10. Repeat soapy water test until no leaks are detected.
11. 

Turn off gas supply at cylinder valve until you are ready to use your fire pit. 

12. 

Wash off soapy residue with cold water and towel dry.

Note: The leak test must be performed in an area that has adequate lighting in order to see if bubbles are

developing and not in a windy or noisy area so larger leaks can be detected by smell or sound.

CAUTION    

Natural Gas leak testing is similar to LP Gas leak testing. The difference is you

need to apply the soapy water mixture to the gas supply pipe nipple.

Figure 236, Page 18

Содержание G3R514S

Страница 1: ...TAIN FOR FUTURE REFERENCE READ CAREFULLY MADE IN CHINA Questions problems missing parts Before returning to your retailer call our customer service department at 1 866 839 2888 8 a m 5 p m EST Monday...

Страница 2: ...Figure 236 Page 2 62 5 cm 24 6 in po 106 7 cm 42 in po...

Страница 3: ...t and caution demanded will reduce the possibilities of personal injury or property damage The following symbols shown below are used extensively throughout this manual Always heed these precautions a...

Страница 4: ...ding matches lighters sparks or open flames of any kind many feet away from the original leak Use only propane gas set up for vapor withdrawal Store or use propane gas in compliance with local ordinan...

Страница 5: ...ustment alteration service or maintenance can cause property damage injury or death Read the installation operation a nd m a i nte na nc e i nstructions thoroughly before installing or servicing this...

Страница 6: ...re pit is on a hard and level surface 13 There are no signs of spider or insect nests 14 All burner passages are clear 15 All air circulation passages are clear 16 Children and adults should be alerte...

Страница 7: ...EXPLODED VIEW Figure 236 Page 7 Glass bead 4kg x 2 box Burner Table top Knob Control panel Ignitor Valve assembly and LP hose LP Reducer NG Reducer NG Hose Table base Top cover...

Страница 8: ...ASSEMBLY INSTRUCTIONS FOR LP Step 1 Step 2 Figure 236 Page 8 Hang the top cover on the side of the fire table Put the glass beads onto the burner DO NOT COVER THE WINDGUARD WITH THE BEADS...

Страница 9: ...5 Figure 236 Page 9 Secure the gas tank to the fire table at the bottom using the bolts Connect the gas to the fire table using LPG regulator Close the fire table Step 4 Open the fire table and instal...

Страница 10: ...Connect the natural gas gray pipe Orifice size NG 3 66mm LPG 2 12 mm LP TRANSFORMATION PART LIST LP reducer with 2 12 mm orifice NG reducer with 3 66 mm orifice LP hose assembly NG hose assembly NG TR...

Страница 11: ...ASSEMBLY INSTRUCTIONS FOR NG Step 2 Step 3 Figure 236 Page 11 Remove the LP hose using wrench Keep the LPG reducer steady using a wrench and loose the pipe using another wrench...

Страница 12: ...ASSEMBLY INSTRUCTIONS FOR NG Step 4 Step 5 Figure 236 Page 12 Disconnect the pipe and the LPG reducer Uninstall the LP reducer LP reducer 2 12...

Страница 13: ...ASSEMBLY INSTRUCTIONS FOR NG Step 6 Step 7 Figure 236 Page 13 Install the NG reducer to the pipe Reinstall the pipe to the reducer using wrench NG reducer 3 66...

Страница 14: ...ASSEMBLY INSTRUCTIONS FOR NG Step 8 Step 9 Figure 236 Page 14 Turn over the fire table Fix the NG hose to the fire table...

Страница 15: ...ASSEMBLY INSTRUCTIONS FOR NG Step 10 Figure 236 Page 15 Install the NG hose to the NG inlet of fire table using wrench Natural Gas Inlet...

Страница 16: ...rmation in these instructions are not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency...

Страница 17: ...as tank by turning knob counterclockwise until it is loose Caution LP gas tank must be properly disconnected and removed prior to moving this pit 1 A professionally installed shut off valve between th...

Страница 18: ...knob counter clockwise until fully opened If you hear a rushing sound or smell gas turn the gas off Tighten any leaking connections If the leak is detected at connection nut and tightening does not st...

Страница 19: ...Always purchase the correct size and grade of battery most suitable for the intended use Clean the battery contacts and also those of the device prior to battery installation Remove batteries from eq...

Страница 20: ...STORAGE FOR TABLE COVER Step 1 Step 2 Step 2 Figure 236 Page 20...

Страница 21: ...and turn control knob counter clockwise to LOW Hold the knob until just before the flames go out 5 Press the IGNITION button and hold for up to 5 seconds to light burner 6 Release control knob after 4...

Страница 22: ...and orifices for blockage Remove blockage and clean burner inside and outside Turn cylinder valve OFF and fill the cylinder Blockage in orifice Control knob is not in ON position Gas pressure is low...

Страница 23: ...nt is detected do NOT operate until repairs are executed 1 Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water 2 For stubborn surfaces use a citrus based degreaser and...

Страница 24: ...e doux GLASS TABLE TOPS CLEANING Use mild soap and water or glass cleansers Do not use abrasive materials or cleansers STONE OR CERAMIC TOPS Don t use harsh abrasive cleansers on any of these products...

Отзывы: