tion of this starting address is achieved by setting the correct number on the display located on the base 
of the device.

You can set the same starting address for all fixtures or a group of fixtures, or make different address for
each fixture individually.

If you set the same address, all the units will start to listen to the same control signal from the same 
channel number. In other words, changing the settings of one channel will affect all the fixtures simulta

-

neously.

f you set a different address, each unit will start to listen to the channel number you have set, based on 
the quantity of control channels of the unit. That means changing the settings of one channel will affect 
only the selected fixture.

In the case of the Profile S300 zoom, which is 1/2/3 channels fixture. If you set, for example, the address 
in the 1 channel mode to channel 2, the device will use the channel 2 for control.

Note:

 After switching on, the device will automatically detect whether DMX 512 data is received or 

not. If there is data received at the DMX input, you will see the DMX indicator light in green.

Universal DMX Control

This function allows you to use a universal DMX-512 controller to control the dimmer and strobe. A DMX 
controller allows you to create unique programs tailored to your individual needs.

RDM control

The Profile S300 can communicate using RDM (Remote Device Management) in accordance with ESTA’s 
American National Standard E1.20-2006: Entertainment Technology RDM Remote Device Management 
Over DMX512 Networks.

RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open stan

-

dard for DMX512 device configuration and status monitoring.

The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting ex

-

isting non-RDM equipment. It allows a console or dedicated RDM controller to send commands to and 
receive messages from specific fixtures.

With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful when 
the device is installed in a remote area.

Each Profile S300 has a factory set RDM UID (unique identification number).

Note:

 Before operation, enable RDM function in Advanced settings.

Содержание PROFILE S300

Страница 1: ...USER MANUAL PROFILE S300 PROFILE S300 300W LED profile spot light...

Страница 2: ...lat surface 4 Mounting the fixture on a truss 4 Securing with a safety cable 4 DMX 512 connection connection between fixtures 5 Power connection 5 Operation 6 Control Menu Map 6 Addressing 6 Universal...

Страница 3: ...of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation oper...

Страница 4: ...ting the fixture on a truss The fixture can be clamped to a truss or similar rigging structure in any orientation When installing the fixture hanging vertically down you can use an open type clamp suc...

Страница 5: ...s helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3 which is then plugged int...

Страница 6: ...Dimmer mode Theatre Studio Studio power mode silent Custom Fade in 150 ms 2230 ms Custom dimmer curve Fade out 150 ms 2230 ms Advance Authorization On Off Advanced settings calibration Only qualified...

Страница 7: ...ed or not If there is data received at the DMX input you will see the DMX indicator light in green Universal DMX Control This function allows you to use a universal DMX 512 controller to control the d...

Страница 8: ...ticles from the outside of the fixture with low pres sure compressed air 3 Clean the surfaces by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub gla...

Страница 9: ...Rendition CRI 97 Lens 19 26 36 50 optional Power connection PowerCON in out Fuse F5A 250V Maximum power linking 6 units Signal connection 3 pin XLR in out DMX channels 1 2 3 Control protocol DMX512 Ho...

Отзывы: