background image

6

V1.47

Securing with a safety cable

Secure the fixture with a safety cable (or other secondary attachment) that is approved for the weight of 
the fixture so that the safety cable will hold the fixture if a primary attachment fails.

Loop the safety cable through the eyebolt in the back of the fixture and around a secure anchoring point. 
Do not loop the safety cable around the fixture’s mounting bracket only, as this will leave the fixture un

-

secured if it separates from the bracket.

DMX-512 connection/connection between fixtures

Occupation of the XLR-connection:

1. Group

2. Signal (-)

3. Signal (+)

DMX OUT

1. Group

2. Signal (-)

3. Signal (+)

DMX IN

If you are using controllers with this occupation, you can connect the DMX-output of the controller directly 
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other 
XLR-outputs, you need to use adapter-cables.

Building a serial DMX-chain:

Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture.
Always connect one output with the input of the next fixture until all fixtures are connected.

DMX-512 connection with DMX terminator:

For installations where the DMX cable has to run a long distance or is in an electrically noisy environ

-

ment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing 
corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with 
a 120 resistor connected between pins 2 and 3, which is then plugged into the output XLR socket of the 
last fixture in the chain.

Caution: 

At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω re

-

Содержание Honor 250T Zoom

Страница 1: ...USER MANUAL HONOR 250T ZOOM Profile Spot Zoom 250W tunable...

Страница 2: ...with a safety cable 6 DMX 512 connection connection between fixtures 6 Power connection 7 Operation 7 Control Menu Map 7 Control menu 8 Main Menu 9 Addressing 9 Universal DMX Control 10 RDM control 1...

Страница 3: ...ing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and ma...

Страница 4: ...tton Enter button Dmx signal indicator Power indicator Handle Rotary button Dmx out Dmx in Fuse Power out Power in On off switch LCD display Yoke Shutters Gobo holder slot Iris slot Focus knob Yoke lo...

Страница 5: ...l over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed be low with a securely anchored safety cable that will hold the fixture if the pri...

Страница 6: ...h the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of...

Страница 7: ...own Live L Blue Neutral N Yellow green Earth Ground Operation The Honor 250T Zoom zoom can operate in three different modes In each mode you can run the fixture as a stand alone fixture or in a master...

Страница 8: ...Hold On Off Run if signal cut RDM On Off RDM function on off Screen Timeout 30S Display shut off time Never Screen Brightness 25 100 Display brightness Dimming Freq 1 20KHz Dimmer frequency setting 1...

Страница 9: ...each fixture individually If you set the same address all the units will start to listen to the same control signal from the same channel number In other words changing the settings of one channel wil...

Страница 10: ...function you can set the DMX address of your fixtures remotely This is especially useful when the device is installed in a remote area Each Honor 250T Zoom has a factory set RDM UID unique identificat...

Страница 11: ...button to enter the main menu 2 Press the UP or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mode sub menu 4 Select disired dimmer mode Custom dimmer curves 1 Press t...

Страница 12: ...mer CH2 Cold white 000 255 0 100 cold white dimmer 3 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 master dimmer CH2 Warm white 000 255 0 100 warm white dimmer CH3 Cold white 000 25...

Страница 13: ...ct the fixture from power and allow it to cool for at least 10 minutes 2 Unscrew the cap of the fuseholder and remove the fuse Replace with a fuse of the same size and rating only 3 Reinstall the fuse...

Страница 14: ...14 V1 47 Please note All information is subject to change without prior notice 05 11 2019...

Страница 15: ...15 V1 47...

Страница 16: ...16 V1 47...

Отзывы: