![Ovation B-2805FC Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/ovation/b-2805fc/b-2805fc_user-manual_1662209017.webp)
Ovation B-2805FC User Manual Rev. 3
O
PERATION
Configuration (DMX/Art-Net™/sACN)
Use control configurations to operate the product with a controller.
Control Protocol
This setting allows you to choose the protocol with which to control the Ovation B-2805FC.
1.
Go to the
Protocol
main level.
2.
Select the desired control protocol (
DMX512
,
ArtNet
, or
sACN
).
Ethernet Setting
Ethernet protocols (Art-Net™ and sACN) require the Universe and IP address to be set, as well as the
.
Universe
1.
Go to the
Ethernet Setting
main level.
2.
Select
Universe
.
3.
Set the Universe value (
0–255
for Art-Net™, or
1–256
for sACN).
IP Address
1.
Go to the
Ethernet Setting
main level.
1.
Select
IP Address
.
2.
Set the IP address (
000.000.000.000
to
255.255.255.255
)
Control Personalities
This setting allows you to choose a particular control personality.
1.
Go to the
Personality
main level.
2.
Select the desired number of cells to be controllable (
1 Cell
,
2 Cell
,
5 Cell
, or
10 Cell
).
Select the desired personality (see table below).
Factory
Setting
No
Reset to factory defaults
Yes
M
ODE
1-C
ELL
2-C
ELL
5-C
ELL
10-C
ELL
DMX-VCW-CCT
3CH
N/A
N/A
N/A
RGB
3CH
6CH
15CH
30CH
RGBA
4CH
8CH
20CH
40CH
RGBAL
5CH
10CH
25CH
50CH
RGB EXT
8CH
15CH
33CH
63CH
RGBA EXT
9CH
17CH
38CH
73CH
RGBAL EXT
10CH
19CH
43CH
83CH
RGBAL Fine
10CH
20CH
50CH
100CH
RGBAL FULL
17CH
31CH
70CH
135CH
•
See the
section for the highest starting address you can select
for each personality.
•
Make sure that the starting addresses on the various products do not overlap due
to the new personality setting.
M
AIN
L
EVEL
P
ROGRAMMING
L
EVELS
D
ESCRIPTION
Содержание B-2805FC