![OVA AIS-SART S9000 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/ova/ais-sart-s9000/ais-sart-s9000_user-manual_1662125004.webp)
3
AIS-SART.
Important hint
Unnecessary self-test will reduce the use time in case of emergency of
AIS-SART
,
each test will consume a small amount of the battery energy. If AIS-SART
has been activated for more than 6 hours (self-test and operation)
,
in accordance
with international regulations, the battery must be replaced to ensure that it could be
used at -20 ° C for 96 hours.
If the test fails, it should need immediate repair.
3,
Activate the device
1. Pull down the protective cover, reveal the "ON"
button
2. Press the "ON" button
3. The red LED will flash once every few seconds
Red LED indicate (AIS-SART on), as shown below:
Flash once every 3.5 seconds
Activate AIS-SART, the buzzer sounds for 0.5 seconds,the LED starts
blinking,flashes once every 3.5 seconds,the signal is transmitted for the first
time after 50 seconds.
If error activation,we could turn off AIS-SART during this
time.
4. GPS positioning instructions: red lights short and long flash once per minute, it
indicates GPS positioning well.
GPS normal
Deactivate AIS-SART
○
2
○
3