Outsunny C00-034V92 Скачать руководство пользователя страница 15

Issues

Cause & Suggestions

Refrigerator does not work.

Check if the switch is on.

Check if the plug and socket are securely connected.

Check to see if the fuse is burnt.

Check if there is damage to the cord.

Frequently switching on/off could cause a delay to the

compressor.

Refrigerator compartments

are too warm.

The door is opened frequently.

A large amount of warm or hot food was recently stored.

The refrigerator has been disconnected for a long time.

Food is frozen.

The temperature is set too low

There is ‘water flowing’

noise from inside the

refrigerator.

This is normal.

There are waterdrops

around the refrigerator

casing or door gap.

This is normal. The moisture will condense to water when it

touches the cold surface.

The compressor is slightly

noisy when starting.

This is normal. The noise will reduce once the compressor

is fully running.

Code F1 displayed.

Possible cause: Low voltage.

Change the battery from high to medium or medium to

low.

Code F2 displayed.

Possible cause: Condenser fan is overloaded.

Disconnect the power to the fridge for five minutes and

restart.

If the code shows again, contact the manufacturer for

service.

Code F3 displayed.

Possible cause: The compressor starts too frequently.

Disconnect the power for five minutes and restart.

If the code shows again, contact the manufacturer for

service.

Code F4 displayed.

Possible cause: Compressor not starting

Disconnect the power for five minutes and restart.

If the code shows again, contact the manufacturer for

service.

Code F5 displayed.

Possible cause: Overheating of the compressor and

electronics.

Disconnect the power for five minutes and restart.

If the code shows again, contact the manufacturer for

service.

Code F6 displayed.

Possible cause: No parameter can be detected by the

controller.

Disconnect the power for five minutes and restart.

If the code shows again, contact the manufacturer for

service.

Code F7 or F8 displayed.

Possible cause: Temperature sensor is faulty.

Contact manufacturer for service.

7

Содержание C00-034V92

Страница 1: ...UESR S MANUAL INafe005_FR_EN IMPORTANT RETAIN FOR FUTURE REFERENCE READ CAREFULLY C00 034V92 FR...

Страница 2: ...TABLE DES MATI RES 4...

Страница 3: ...arche laissez l appareil sur une surface plane pendant plus de six heures Maintenez l appareil l horizontale lorsqu il est en marche N obstruez pas les ouvertures de ventilation de l appareil Maintene...

Страница 4: ...hen Verwendung bestimmt Compresseur CC haut rendement et module de conversion Sans CFC et bonne isolation thermique Refroidissement rapide jusqu 20 C 4 F bas sur une temp rature ambiante de 25 C 77 F...

Страница 5: ...rsque le r frig rateur est sous tension le buzzer met un son long l cran s affiche pendant deux secondes et l appareil passe en mode veille Marche arr t Appuyez pour allumer et maintenez le pendant tr...

Страница 6: ...ffon doux Placez l appareil dans un endroit frais et sec L humidit peut former du givre l int rieur de l appareil ou sur l vaporateur Cela r duit la capacit de refroidissement D givrez l appareil pour...

Страница 7: ...7 DEPANNAGE...

Страница 8: ...8cu ft 60L 2 1cu ft BRUIT 45 dB PLAGE DE R GLAGE DE LA TEMP RATURE 20 20 C 4 68 F CAT GORIE CLIMATIQUE T ST N SN DIMENSIONS L W H 711 460 441mm 28 18 1 8 17 3 8 pouces 711 460 506mm 28 18 1 8 19 15 16...

Страница 9: ...UESR S MANUAL IMPORTANT RETAIN FOR FUTURE REFERENCE READ CAREFULLY INafe005_FR_EN C00 034V92 EN...

Страница 10: ...4...

Страница 11: ...vel surface for more than six hours Keep the appliance horizontal when on Do not obstruct the ventilation openings of the appliance Keep the appliance stable on the ground or in the car Do not drain u...

Страница 12: ...cy DC compressor and conversion module CFC free and good heat insulation Fast cooling to 20 C 4 F based on 25 C 77 F room temperature Intelligent battery protection system prevents appliance from dyin...

Страница 13: ...When the fridge is powered on the buzzer will make a long sound the display will show for two seconds and the appliance will enter standby mode Power on off Press to switch on and hold for three seco...

Страница 14: ...cloth Put the appliance in a cool and dry place Leave the lid slightly open to prevent any odours Humidity can form frost on the inside of the device or on the evaporator This reduces the cooling cap...

Страница 15: ...e Change the battery from high to medium or medium to low Code F2 displayed Possible cause Condenser fan is overloaded Disconnect the power to the fridge for five minutes and restart If the code shows...

Страница 16: ...034 8 Input voltage 100 240 V Input AC frequency 50 60 Hz Output voltage 14 5 V Output current 6 A Output power 90 W Average active efficiency 87 Efficiency at low load 10 79 No load power consumption...