background image

9.7  Input/output protection

Interference protection is implemented in the M Series to limit 

out of band noise carried by the input lines. Disturbing frequencies 
can interact with the output stage, causing unpredictable amplifier 
behavior.  A  filtering  system  is  used  to  stop  infrasonic  and  VHF 
signals from entering the signal path.

10  User Maintenance

10.1   Cleaning

Before  attempting  to  clean  any  part  of  the  amplifier,  first 

disconnect  the AC  main  source.  Use  a  soft  cloth  and  mild  non-
abrasive solution to clean the faceplate and chassis. 

WARNING!  Never  let  any  liquid  reach  the  internal  parts  of 

the amplifier.

10.2   Service

There  are  no  user-serviceable  parts  in  your  amplifier.  Refer 

servicing to qualified technical personnel.  If your amplifier needs
repair  contact  your  Outline  dealer. You  can  also  contact  the
Outline  Technical Service department.

goods covered by product warranty at its sole discretion and as 
it deems best.

11.3   Cost and responsibility of transport

The  purchaser  (or  end  user/customer)  is  solely  responsible 

for  all  transportation  costs  and  risks  associated  with  sending 
warranty covered goods to Outline  or its Authorized Service 
Center.  Outline will  assume  full  responsibility  and  cover  all  costs 
incurred to send the goods back to the purchaser (or end user/
customer).

10.3   Dust Removal

In dusty environments, the front side air filters clog with dust 

after prolonged use. The dust gathered in the filters will interfere 
with  cooling.  You  may  use  compressed  air  to  remove  the  dust 
from filters. To remove air filters please refer to the front panel 
removal procedure (see Section 8.1). Air filter cleaning should be 
scheduled according to the dust levels in the amplifier’s operating 
environment.

11  Warranty

11.1   Product warranty

Outline  guarantees its manufactured products to be free from 

defective components and factory workmanship for a period of 48 
(forty eight) months, starting from the date of purchase printed on 
Outline   (or  any  of  its  Authorized  Dealer’s)  invoice  to  the  end
customer. All warranty repairs and retrofits must be performed at 
Outline  facilities or at an Authorized Service Center at no cost 
for  the  purchaser. Warranty  exclusion:  Outline ’s  warranty  does
not  cover  product  malfunctioning  or  failure  caused  by:  misuse, 
abuse,  repair  work  or  alterations  performed  by  non-authorized 
personnel,  incorrect  connections,  exposure  to  harsh  weather 
conditions, mechanical damages (including shipping accidents), and 
normal  wear  and  tear.  Outline   will  perform  warranty  services
provided that the product is not damaged during transportation.

 

 

11.2    Repair or replacement

Outline  reserves the right to repair or replace any defective 

12  Power rating

Single-channel mode

Distributed lines

Mono-bridge 

mode

70 V

100 V

1250 W

750 W

1000 W

1

1250 W

2

2500 W

1 with an external high pass filter and output voltage limiter.

 

2 with an external high pass filter.

Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy

Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it  E-Mail: [email protected]

11

Professional Amplifier

M5000-4

Содержание M5000-4

Страница 1: ...The Sound of Big Ideas M5000 4 FOUR CHANNEL AMPLIFIER The Sound of Big Ideas USER GUIDE TEMP READY SIGNAL 18dB 6dB CLIP dB 32 8 dB 32 8 M5000 4...

Страница 2: ...regarding installation 3 Mechanical drawings 4 Interfaces 5 Welcome 6 Description 7 Installation M5000 4 User Guide 9 Protection 10 9 1 Turn on Turn off muting 10 9 2 Short circuit protection 10 9 3 T...

Страница 3: ...EN 55103 2 standard This equipment has been tested and found to comply by Notified Body 2014 Directive 2006 95 EC pursuant to the audio appa ratus safety requirements EN 60065 and EN 6006 A1 standard...

Страница 4: ...are capable of producing much more power than many loudspeakers can han dle It is the user s responsibility to use speakers suitable to the amplifier and to use them in a sensible way that will not c...

Страница 5: ...drawing All dimensions in millimiters TEMP READY SIGNAL 18dB 6dB CLIP dB 32 8 dB 32 8 M5000 4 Outline s r l Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 30 3581341 Fax 39 30 3580431 Web...

Страница 6: ...13 Link switch channels 3 4 14 Channel 3 output Speakon connector 15 Channel 2 output Speakon connector 16 Link switch channels 1 2 17 Channel 1 output Speakon connector FIGURE 2 M5000 4 front panel v...

Страница 7: ...to work with lo Z from 4 and with 70V 100V distributed lines It can deliver up to 1250 W per channel at 4 or 2500 W in bridge mode on 8 Outline amplifiers deliver crystal clear highs and a tight well...

Страница 8: ...the acceptable operating voltage range specified in the M5000 4 documentation factory selected 115 V 230 V 15 depending on your country mains standard Damage caused by connecting the amplifier to an...

Страница 9: ...LED will turn off automatically when the temperature falls below 75 C TABLE 1 M5000 4 LEDs chart 8 4 Connecting audio inputs Audio input connections are made via four XLR connectors found on the rear...

Страница 10: ...for another 2 seconds and the procedure will reiterate The red CLIP LED will be turned off only when the output current draw will have returned within safe limits 9 3 Thermal protection Outline M5000...

Страница 11: ...l interfere with cooling You may use compressed air to remove the dust from filters To remove air filters please refer to the front panel removal procedure see Section 8 1 Air filter cleaning should b...

Страница 12: ...0 100 Hz Front panel Indicators 4 LEDs per channel 3 x green 1 x red 4 status LEDs 2 x green 2 x yellow Controls 1 stepped level attenuator pot per channel mains switch Maintenance Dust filter foam be...

Отзывы: