[email protected]

Accessories

  On request is available an adjustable support stand for small loudspeakers in size useful to get the measures

in the middle height of the room, far as possible from the reflections.

  It is also available on request a cable adapter to manage at the same time two electronic control ET1.1 with the

ET Commader program supplied.

ET1.1 (or ET1 upgraded) connections

1)  Measurement cards (LMS, MLSSA, CLIO,

TEF).
Pin 1, 3, 6, 7, 8, 9 : not connected
Pin 2 : start pulse
Pin 4 : ground
Pin 5 : return pulse

2)  ST2 (ST1) master turntable

Pin 2, 7, 8 : not connected
Pin 1 : Vss motor
Pin 3 : + 12V
Pin 4 : Gnd
Pin 5 : step control
Pin 6 : Vdd motor
Pin 9 : zero position control

3)  PC control. It is supplied a parallel adapter

to use Outline ET Commander.
See “Control protocol”

4)  ST2 (ST1) slave turntable. This must always

used with a ST2 master turntable.
Pin 2, 3, 4, 5, 7, 8, 9 : non connected
Pin 1 : Vss motor
Pin 6 : Vdd motor

ST2 (ST1) connection

ST2 (ST1) master turntable
Pin 1 : Vdd motor
Pin 2 : Vss motor
Pin 3 : + 12V
Pin 4 : Gnd
Pin 5 : step control
Pin 6 : zero position control

 

ST1 turntable 

MASTER 

Measurement card 

(LMS, MLSSA, 

CLIO, TEF) 

ST1 turntable 

SLAVE (reverse) 

Control from 

 PC 

Содержание ET1.1-ST2

Страница 1: ...ST2 Electronic turntable professional instruments outline s n c di noselli g c v leonardo da vinci 56 25020 flero bs italy tel 39 30 3581341 fax 39 30 3580431 Web Site http www outline it E Mail outli...

Страница 2: ...able connector on rear panel Slave turntable spin always in opposite sense respect master turntable and is passive don t is possible control directly slave turntable without master turntable RESET pus...

Страница 3: ...rntable is driven by TTL pulse on MLSSA PC CARD connector DB9 Connection wiring are included with the turntable Connection wiring are included also from turntable ST2 to electronic control ET1 1 with...

Страница 4: ...AC POLFIX35 MAC makes 24 measurements with different angular positions set the selector switch DEG STEP to 15 degrees step Example Operation The macro program menu is selected by pressing the M key at...

Страница 5: ...out different dedicated electronics circuits Even if is not necessary to change the values of SCP15 and SCP19 it is recommended to speed up the measurement These arrangements must be executed before m...

Страница 6: ...on with MLSSA version 8 1A software and following versions Using older MLSSA version it is possible that turntable skips a rotation degree s step failing the actual measurement Because MLSSA use the c...

Страница 7: ...se LPTBIT 4 Controls first turntable with LPT BIT 4 STATUS 0 Sets BIT 4 to OFF CYCLIC STP GLOBALS COMPANY MY COMPANY Company Name TITLE POLAR MEASUREMENTS Measurements Title MANUAL 0 Sets tests to aut...

Страница 8: ...graded connections 1 Measurement cards LMS MLSSA CLIO TEF Pin 1 3 6 7 8 9 not connected Pin 2 start pulse Pin 4 ground Pin 5 return pulse 2 ST2 ST1 master turntable Pin 2 7 8 not connected Pin 1 Vss m...

Страница 9: ...Pin 4 unit B movement behind bit Reading bits Pin 6 unit A step bit Pin 7 unit B step bit Pin 8 unit A zero position bit Pin 9 unit B zero position bit Example of unit A control Pin 1 Pin 3 Pin 6 Pin...

Страница 10: ...e Precision 0 25 Rotation system control optoswitch with flying spot scanning Input output connections 9 pins sockets DB9 Input pulse TTL from 5 to 12 VCC imp 680 Ohm Output pulse TTL with variable de...

Отзывы: