Heat Sensitive
Hand Wheel
Regulator
Cylinder
Shut Off Valve
Check Valve
Nipple with
Flow Limiting Device
CONNECTION:
1.
Be sure the cylinder valve and appliance valves are “off”.
2. Place full LP gas cylinder on tank stabilizer ring.
3. Center the nipple in the cylinder valve and hold in place.
4. Using the other hand, turn the hand wheel clockwise until there
is a positive stop. Do not use tools.
5. Hand tighten only. When making the connection, hold the
regulator in a straight line with the cylinder valve, so as not to
cross thread the connection.
6. Leak test the connection. See section named “LEAK TEST”.
WARNING:
Ensure that the LP gas cylinder is kept at a minimum
distance of three feet (36 inches) away from the appliance.
All LP cylinders to be used with this appliance must be:
a. Constructed and marked in accordance with the
specifications for LP-gas cylinders Standard,
CAN/CSA B339, Cylinders, Spheres and Tubes for the
Transportation of Dangerous Goods.
b. Provided with a listed overfilling prevention device.
c.
Provided with a cylinder connection device compatible with the
connection for outdoor cooking appliances.
d. Only a 20 lb. (9 kg) LP gas cylinder is to be used for this
appliance.
e. Approximately 18” (46 cm) high & 12” (30 cm) diameter.
f. The use of an approved LP gas cylinder stabilizer, such as the
one included, must be used when using this appliance in order
to prevent the LP gas cylinder from tipping over.
ENCLOSURES FOR SELF-CONTAINED
LP GAS SYSTEMS:
An enclosure for an LP-gas cylinder shall be ventilated by openings
at both the upper and lower levels of the enclosure. This shall be
accompanied by one of the following:
a. One side of the enclosure shall be completely open; or
b . For an enclosure having four sides, a top, and a bottom:
At least two ventilation openings (see Part IV, Definitions) shall be
provided in the sidewalls of the enclosure, located within
5 in (217 mm) of the top of the enclosure, equally sized, spaced
at a minimum of 90 degrees (1.57 rad), and unobstructed. The
opening(s) shall have a total free area of not less than 1 in
2
per lb
(14.2 cm
2
per kg) of stored fuel capacity.
Ventilation opening(s) shall be provided at floor level of the
enclosure and shall have total free area of not less than 1/2 in
2
per
lb (7.1 cm
2
per kg) of stored fuel capacity. If ventilation openings
at floor level area are in the side wall, there shall be at least two
openings. The bottom of the openings shall be 1 in (25.4 mm) or
less from the floor level and the upper edge no more than 5 in (127
mm) above the floor level. The openings shall be equally sized,
spaced at a minimum of 90 degrees (1.57 rad), and unobstructed.
Every opening shall have minimum dimensions so as to permit the
entrance of a 1/8 in (3.2 mm) diameter rod. Ventilation openings in
sidewalls shall not communicate directly with other enclosures of
the appliance.
3
Owner & Safety Manual
D.850.000.V0
OUTLAND FIREBOWL
®
MEGA OWNER & SAFETY MANUAL
Appliance
Tank Ring
Minimum 36"
LEAK TEST: Apply the solution to the LP gas delivery system at points.
Valve coupling regulator & Cylinder Coupling.
LEAK TEST: Apply the solution to the LP gas delivery
system at points:
1. Firebowl Valve Coupling
2. Gas Hose Regulator
3. Cylinder Valve Coupling
LP
Cylinder