background image

Heat Sensitive

Hand Wheel

Regulator

Cylinder 

Shut Off Valve

Check Valve

Nipple with

Flow Limiting Device

CONNECTION:

1.  

Be sure the cylinder valve and appliance valves are “off”.

2.  Place full LP gas cylinder on tank stabilizer ring.
3.   Center the nipple in the cylinder valve and hold in place. 
4.   Using the other hand, turn the hand wheel clockwise until there 

is a positive stop. Do not use tools. 

5.   Hand tighten only. When making the connection, hold the 

regulator in a straight line with the cylinder valve, so as not to 
cross thread the connection.

6.   Leak test the connection. See section named “LEAK TEST”.

 

 WARNING:

Ensure that the LP gas cylinder is kept at a minimum 
distance of three feet (36 inches) away from the appliance.

All LP cylinders to be used with this appliance must be: 
a.   Constructed and marked in accordance with the 

specifications for LP-gas cylinders Standard,  
CAN/CSA B339, Cylinders, Spheres and Tubes for the 
Transportation of Dangerous Goods.
 

b.  Provided with a listed overfilling prevention device.
c.  

Provided with a cylinder connection device compatible with the 
connection for outdoor cooking appliances. 

d.   Only a 20 lb. (9 kg) LP gas cylinder is to be used for this 

appliance.

e.   Approximately 18” (46 cm) high & 12” (30 cm) diameter.
f.   The use of an approved LP gas cylinder stabilizer, such as the 

one included, must be used when using this appliance in order 
to prevent the LP gas cylinder from tipping over.

ENCLOSURES FOR SELF-CONTAINED  

LP GAS SYSTEMS:

An enclosure for an LP-gas cylinder shall be ventilated by openings 
at both the upper and lower levels of the enclosure. This shall be 
accompanied by one of the following:

a.   One side of the enclosure shall be completely open; or

b .  For an enclosure having four sides, a top, and a bottom:

At least two ventilation openings (see Part IV, Definitions) shall be 
provided in the sidewalls of the enclosure, located within  
5 in (217 mm) of the top of the enclosure, equally sized, spaced 
at a minimum of 90 degrees (1.57 rad), and unobstructed. The 
opening(s) shall have a total free area of not less than 1 in

2

 per lb 

(14.2 cm

2

 per kg) of stored fuel capacity.

Ventilation opening(s) shall be provided at floor level of the 
enclosure and shall have total free area of not less than 1/2 in

2

 per 

lb (7.1 cm

2

 per kg) of stored fuel capacity. If ventilation openings 

at floor level area are in the side wall, there shall be at least two 
openings. The bottom of the openings shall be 1 in (25.4 mm) or 
less from the floor level and the upper edge no more than 5 in (127 
mm) above the floor level. The openings shall be equally sized, 
spaced at a minimum of 90 degrees (1.57 rad), and unobstructed.

Every opening shall have minimum dimensions so as to permit the 
entrance of a 1/8 in (3.2 mm) diameter rod. Ventilation openings in 
sidewalls shall not communicate directly with other enclosures of 
the appliance.

3

Owner & Safety Manual

D.850.000.V0

OUTLAND FIREBOWL

®

 MEGA OWNER & SAFETY MANUAL 

Appliance

Tank Ring

Minimum 36"

LEAK TEST: Apply the solution to the LP gas delivery system at points.  

Valve coupling regulator & Cylinder Coupling. 

LEAK TEST: Apply the solution to the LP gas delivery 

system at points: 

1. Firebowl Valve Coupling 

2. Gas Hose Regulator 

3. Cylinder Valve Coupling

LP 

Cylinder

Содержание FMPPC2B

Страница 1: ...FMI BRANDS INC 309 19133 26th Avenue Surrey B C Canada V3Z 3V7 Toll Free 1 888 514 1663 Fax 1 888 797 9931 D 850 000 V0 Owner s Manual Model number FMPPC2B Series number 850...

Страница 2: ...NING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this...

Страница 3: ...ncluded must be used when the appliance is in use Replacement parts and a list of such parts are available from FMI Brands Inc through the contact information provided on the last page of this Manual...

Страница 4: ...entilated by openings at both the upper and lower levels of the enclosure This shall be accompanied by one of the following a One side of the enclosure shall be completely open or b For an enclosure h...

Страница 5: ...replacement hose Inspect burner prior to each use Burner must be replaced prior to the appliance being put into operation if there is evidence of damage Replacement burners are available from FMI Bra...

Страница 6: ...P 6 Your included Cover is to be used for storage and transportation as shown in the following image Never use the cover to extinguish the flame on your Outland Firebowl SECTION 2 IGNITION STEP 1 Ensu...

Страница 7: ...e cylinder valve Open and then close Firebowl gas knob valve to release pressure Disconnect and reconnect the propane cylinder valve connection Slowly open propane cylinder valve Perform Leak Test and...

Страница 8: ...me for your Outland Firebowl using a full 20 lb 9kg propane cylinder is between 7 and 11 hours depending on where the flame height is set FMI Brands Inc recommends that you ignite this unit only when...

Отзывы: