INSTALLATION

The recommended installation position is up-right as shown 

in Fig 2, view "D". It has two (2) inlet and two (2) outlet gas 

connections.  The diagrams below provide possible ways to 

plumb the E-Stop (See Fig. 3).  Two (2) ½” NPT plugs are 

provided with the E-Stop.  Plug the inlet and outlet 

connections not being used for the application.  Connect gas 

supply to the inlet with the           arrow pointing into the 

valve. Connect outlet side to the gas appliance (See Figs. 2 & 

3 for details).

NOTE:

  Conduct a gas leak test on the E-Stop Gas Timer after 

plumbing is complete.

OPERATION

TO TURN ON

Step 1

: Rotate the clear timer dial past 20 (ESTOP1-0H) or 

past 0.5 (ESTOP2-5H) to set the time. Timer will begin 

“ticking” when the dial is turned while the countdown time 

is set.  

Step 2:

 Turn red knob clockwise (about a ¼ turn) 

until it pops outward. Gas will now flow to enable you to 

light the appliance.

TO TURN OFF:

Let timer expire or simply press red knob inward until it 

stops.  The red knob will lock down with a “click” and stop 

gas flow. See Fig. 4 and Fig. 5 on following page.

Note:

 Do not force the timer dial to the OFF position after 

time is set 

(This will weaken the spring inside the timer body 

and affect the accuracy of the time).

Timer Dial

:

Rotate clockwise to 

start time.  Adjust dial 

to desired time frame.

Red Knob:

Turn clockwise and 

knob will “pop” up 

to allow gas flow.

PUSH TO STOP
TURN TO START

OFF

TURN

PAST

20

40

60

MINUTES

Fig. 4

 E-Stop operation.

BACK VIEW

Inlet

Inlet

Outlet

Outlet

SIDE IN

SIDE OUT

BACK

IN

BACK

OUT

Fig. 2

 Inlet and outlet connections.

“A-C” Shows Top View of E-Stop

Inlet

Outlet 

D

“D” Shows Front View of 

E-Stop

PUSH TO STOP
TURN TO START

OFF

TURN

PAST

20

40

60

MINUTES

Inlet

Outlet 

C

Inlet

Outlet

B

Inlet

Outlet

A

Fig. 3 

Plumbing options

www.TheOutdoorPlus.com

Page 3

909-460-5579

Содержание OPT-ESTOPTM

Страница 1: ...s and 2 outlets Maximum Pressure PSI CSA Rated Capacity 165 000 Btu Hr at 1 Pressure Drop NG Ambient Temperature 0 F to 175 F 79 C Timer Accuracy 60 Min 15 or 2 5 Hrs 15 Inlets Have fine mesh screens to filter any debris Multiple Mounting Holes Uses 3 16 24 machine threads Designed For Natural or LP Gas no conversion required CSA Certified Tested to ANSI Z21 21 CSA 6 5 WARNING Read these instructi...

Страница 2: ...o position Note We recommend using stainless steel screws for any outdoor applications See Fig 1 for details 2 0 Inlet 1 0 Outlet 0 5 1 0 1 5 2 0 2 5 3 0 Inlet 1 5 Outlet 4 0 Inlet 2 0 Outlet 250 000 275 000 300 000 325 000 350 000 375 000 400 000 Btu Hr Pressure Drop Capacity Curve E Stop Timer LP Gas 5 0 Inlet 2 5 Outlet 3 0 425 000 450 000 Note Pressure drop information listed is generated in A...

Страница 3: ... turn until it pops outward Gas will now flow to enable you to light the appliance TO TURN OFF Let timer expire or simply press red knob inward until it stops The red knob will lock down with a click and stop gas flow See Fig 4 and Fig 5 on following page Note Do not force the timer dial to the OFF position after time is set This will weaken the spring inside the timer body and affect the accuracy...

Страница 4: ...s that vary by state province or nation Symptom Remedy No gas flow 1 Rotate dial beyond the turn past position 2 Ensure red knob is protruding outward in ON position 3 Has time has expired on timer If so re start timer again 4 Ensure primary gas supply is turned ON 5 Ensure the gas timer is plumbed properly 6 Look for any physical damage 7 Ensure other gas valves before or after the timer are oper...