1) Turn

 

LP

 

Cylinder

 

gas valve to fully open position and 

press “

       

” button on the  control  panel.  If

 

the sparks 

stop and burner does not stay lit, press the button “ 

    

” again 

to ignite after 10 seconds.    
2)

 

When

 

the

 

burner

 

is

 

lit, press “

           

” or “ 

     

” to desired 

heat output between High and Low.     
3) To shut off heater, press “

   

”again,

 

then

 

turn

 

LP cylinder 

gas valve to closed position. If you want to relight the heater, 
wait 5 minutes, and  then  repeat the Steps 1 to 2.

   

     

14

Содержание Curve MTC-CURVE-GM-LP

Страница 1: ......

Страница 2: ...upplier or fire department Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER WARNING WARNING For Outdoor Use Only CAUTION Installer Leave the manual instructions to the user for future use Consumer Please keep this manual for...

Страница 3: ...operty damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNINGS AND CAUTIONS SPECIFICATION Certification C 74 x 31 5 x 93 7 1880x800x2380mm SA Product size Rated heat input 32 000 BTU hr Fuel LP Gas Supply 20 lb 9 kg LP gas cylinder Manifold pressure 3PSI Diameter of injector 0 039 0 99 mm Safety features ...

Страница 4: ...rip over it or in areas where the hose will not be subject to accidental damage Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required a...

Страница 5: ...e used must be Constructed and marked in accordance with the Specifications for LP gas cylinders of the U S Department of Transportation DOT or the Standard for Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Com mission CAN CSA B339 as applicable Provided with a listed overfilling prevention device and provided with a cylinder connection device compatible with the connection...

Страница 6: ...G SAFETY RULES TOOLS NEEDED Estimated time for assembly 30 minutes Philips screwdriver PREPARATION Before beginning assembly of product make sure all parts are present If any part is missing or damaged do not attempt to assemble the product Contact customer service for replacement parts Perform a leak test with a soapy solution 1 To check gas connections 2 After connecting a new cylinder 3 Upon re...

Страница 7: ...EXPLODED VIEW 1 2 3 4 6 ...

Страница 8: ...PARTS LIST Description Picture Part 1 Transom assembly 1 1 1 Pole base assembly Cylinder fixing hook 2 4 Qty 7 3 Decorative cover 1 ...

Страница 9: ...the heater from the pallet and then screw these 6pcs M5 x 12 bolts back to the base of the heater NOTE PLEASE FOLLOW THE FOLLOWING STEPS TO REMOVE THE PALLET Unscrew 8pcs M5 x 20 bolts from fixing bar M5 x 12 bolts M5 x 12 bolts Fixing bar M5 x 20 bolts M5 x 20 bolts 8 ...

Страница 10: ... the decorative cover 3 through the pole 2 and place it on the tabletop 2 Shoulder screw on pole Pole fixing sleeve Table of base assembly 9 3 STEP 2 Unscrew M8 x 85 bolt and M8 cap nut on Transom assembly 1 M8 x 85 bolt M8 cap nut 1 ...

Страница 11: ...is at the same side as wheels Insert the hose and regulator through the pole 2 and place the transom assembly 1 on the pole 2 Insert M8 x 85 bolt through the hole of transom assembly 1 and pole 2 and secure them with M8 cap nut Finally tighten other 3pcs M8 cap nuts Note It is recommended that two people perform this step with extra caution Note Do not take out ...

Страница 12: ...nded inactivity Battery compartment cover Battery compartment D size batteries 2pcs not included M4 x 10 bolts 4pcs 11 STEP 5 Insert cylinder fixing hook 4 into holes on base assembly 2 Place the gas cylinder not included into the base assembly 2 and fix it with cylinder fixing hook 4 Attach the regulator to the cylinder and turn clockwise to securely tighten the valve Close and latch the door Not...

Страница 13: ...s appear there is leakage Loosen and re tighten this connection If connection still leaks please call customer service 1 866 814 0585 Note 1 The cylinder supply system must be arranged for vapor withdrawal 2 The cylinder used must include a collar to protect the cylinder valve regulator cylinder connection WARNING ONLY AN AUTHORIZED GAS TECHNICIAN SHOULD INSTALL THIS PRODUCT 12 The hose assembly m...

Страница 14: ...immediately 4 Check for leaks according to the above step by step after replacing the hose regulator WARNING ONLY AN AUTHORIZED GAS TECHNICIAN SHOULD INSTALL THIS PRODUCT e If no bubbles appear the connection is safe battery compartment cover 4pcs M4 x 10 bolts inlet pipe fitting and metal hose fitting f If bubbles appear there is a leak Shut off the LP gas cylinder valve loosen and then re tighte...

Страница 15: ...ner does not stay lit press the button again to ignite after 10 seconds 2 When the burner is lit press or to desired heat output between High and Low 3 To shut off heater press again then turn LP cylinder gas valve to closed position If you want to relight the heater wait 5 minutes and then repeat the Steps 1 to 2 14 ...

Страница 16: ...the heater should be turned off immediately The heater should not be operated again until the unit is serviced and or repaired A little flame A lot of yellow flames waft from the burner cover SRPH72 WIRING DIAGRAM CONTROL PANEL POWER HIGH LOW SAMPLE SAMPLE HV OUT HIGH VALVE LOW VALVE DC3 0V SPARK PIN TILT SWITCH THERMOCOUPLE RED WIRE BLACK WIRE BATTERY D 1 5X2 RED WIRE BLACK WIRE GAS IN GAS OUT 15...

Страница 17: ...press the control knob to the press 15 16 ...

Страница 18: ...ily used for the heating of outdoor patios decks spas pools and open working areas Always make sure that adequate fresh air ventilation is provided Follow the spacing tolerances shown in the following figure right at all times This heater must be placed on level firm ground Never operate in an explosive atmosphere Keep away from areas where gasoline or other flammable liquids or vapors are stored ...

Страница 19: ...T try to use it It must be replaced Keep the appliance area free and clean from combustible materials gasoline and other flammable vapors and liquids not obstructing the flow of combustion and ventilation air keeping the ventilation opening s of the cylinder enclosure free and clear from debris Gas odor with extreme yellow tipping of flame Heater does NOT reach the desired temperature Heater glow ...

Страница 20: ...r Compressed air may help clear away smaller particles Carbon deposits may create a fire hazard Clean dome with warm soapy water if any carbon deposits develop STORAGE Between uses During periods of extended inactivity or when transporting Take out the batteries from the battery compartment Disconnect the regulator from the LP Cylinder by turning counter clockwise and move to a secure well ventila...

Страница 21: ...20 ...

Страница 22: ...21 one 1 OUTDOOR ORDER LLC 1 866 814 0585 cs outdoororder com ...

Страница 23: ...rranty Tough enough for the most demanding commer cial environment and yet accessible to the discriminating consumer Outdoor Order products stand alone in an industry we are proud to be a part of As an original equipment manufacturer Outdoor Order has been delivering unri valed quality and unprecedented design to our partners for over a decade No problem is too small and no order is too big thats ...

Страница 24: ......

Отзывы: