Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffi c and away from furniture and draperies.
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
WARNING! Risk of Fire! The exterior side of the
TWILIGHT-II-MOD CANNOT be recessed into the
framing.
Figure 5.1 Appliance Locations
GLASS
EXTERIOR INSULATED ENVELOPE
GLASS
A
B
B
D
C* = 24 INCH (MAX.)
B
GLASS
FLUSH TO EXTERIOR INSULATED ENVELOPE
GLASS
E
C*
NOTE: Appliance may be installed flush on exterior, interior
or anywhere in between. Any projection of the appliance
interior or exterior must have a properly constructed chase
surrounding the appliance. The exterior must have proper
insulating, flashing and finishing to ensure an insulated
envelope.
FLUSH TO INTERIOR
PROJECTION
C* = 0 INCH (MIN.)
WARNING! Risk of Fire! The exterior side of the TWILIGHT-II-MOD
CANNOT be recessed into the framing.
A
B
C*
D
E
Minimum
Minimum
Minimum
Maximum
Minimum
-
Inches
43 1/2
0
24
36
43
Millimeters
1092
13
0
610
914
1092
* = C dimension may be any length from 0 to 24 inches.