• Outdoor Lifestyles by Hearth & Home Technologies Burner/Hearth Kits • 4004-315 Rev D • 5/2013
7
A. Gas Supply Connection
A 3/8 in. flared fitting has been installed on the gas valve
inlet at the factory. Ensure fittings are of the appropriate size
and type on the gas line connection. If the tubing has to be
cut to length be sure to use the proper cutting and flaring
tool. Also, be careful not to crimp the tubing while bending. If
the tubing becomes crimped, do not use for installation.
Fire Risk
Explosion Risk
Verify inlet pressures.
• H i g h p r e s s u r e m a y c a u s e o v e r f i r e
condition.
• Low pressure may cause explosion.
Install regulator upstream of valve if line
pressure is greater than 1/2 psig.
WARNING
3
Appliance Preparation
B. Convert to Left Side Gas Piping
• Remove black cap from left side.
• Remove two pilot head screws.
• Remove two pilot bracket screws.
• Detach thermocouple and pilot from control valve.
•
Remove the control valve from the right side of the burner
pan and replace on left, upside down.
Note:
Prior to installing, use Teflon tape or Joint compound
on the male threads.
• Reinstall pilot bracket on left side of burner.
• Reinstall pilot assembly to pilot bracket.
• Reattach pilot tube and thermocouple to control valve.
• Reinstall black cap removed from left side of burner to
right side.
• Install valve shield.
Note:
An individual manual shutoff valve (not supplied) is
required when installing this appliance. The manual shutoff
valve must be located in an easily accessible area, no more
than 6 feet from the appliance.
Note:
Have the gas supply line installed in accordance
with local building codes, if any. If not, follow
ANSI 223.1
.
Installation should be done by a qualified installer approved
and/or licensed as required by the locality. (In the Common-
wealth of Massachusetts installation must be performed by
a licensed plumber or gas fitter.)
Note:
A listed (and Commonwealth of Massachusetts
approved) 1/2 in. (13 mm) T-handle manual shut-off valve
and flexible gas connector are connected to the 1/2 in.
(13 mm) control valve inlet.
•
If substituting for these components, please consult
local codes for compliance.
WARNING
Gas Leak Risk
• Support control when attaching pipe to
prevent bending gas line.
WARNING
Fire Risk
Explosion Risk
• Gas build-up during line purge may
ignite.
• Purge should be performed by qualified
technician.
• Ensure adequate ventilation.
•
Ensure there are no ignition sources such
as sparks or open flames.
Fire Risk
Explosion Risk
Personal Injury Risk
An explosion could occur if a connection is
made directly to an unregulated propane (LP)
tank.
WARNING
Joint compound ot Teflon tape must be used on all threaded
male connections to ensure a tight seal.