10
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina-B Installation Manual • 4066-500 Rev. B • 5/14
6 in.
6 in.
6-1/2 in. min.
24 in. min.
cement
board from
the top of the
firebox
opening
24 in. min.
noncombustible
finishing
material
82 in.
(2083 mm)
floor to ceiling
0 in.
Combustible Object
36 in.
(914 mm)
Front
Back
Note:
If this surface is
inside the building’s
warm air envelope...
...then this surface
must be an exterior
wall system.
57 in.
(1448 mm)
minimum
1 1/2 in.
(38 mm)
56 in.
(1422 mm)
79 1/4 in.
(2013 mm)
17 in.
(432 mm)
48 in.
(1219 mm)
1 1/2 in.
(38 mm)
1 1/2 in.
(38 mm)
Control
Box
ControlBox
42 3/4 in.
(1086 mm)
minimum
header height
42 3/4 in.
(1086 mm)
minimum
header height
56 3/4 in.
(1441 mm)
minimum
to top of cement
board
17 in.
(432 mm)
Flashing
Cement Board
Control box
MUST be
relocated!
Exterior
Interior
11 1/2 in.
(292 mm)
minimum
8-1/4 in.
(210 mm)
10-5/8 in.
(270 mm)
48 in.
(1219 mm)
48 in.
(1219 mm)
Framing
36 in. minimum
(889 mm)
from appliance front
Side clearances can be zero at framing,
up to 6 inches deep
Side clearances can be zero at framing,
up to 6 inches deep
6 in.
6 in.
36 in. minimum
(889 mm)
from appliance front
N o t e:
Fo r ac tual applianc e
dimensions refer to Section 3.A.
Figure 3.3 Appliance Locations and Framing Dimensions - CARODG36I-B
NOTICE:
Vinyl siding must
not be placed between the
appliance opening and the
ceiling/overhang.
NOTICE:
Flash the perimeter of the appliance, corners
and the appliance face in a manner consistent with
regional practices as required to prevent water penetration
around the appliance or manage water that may penetrate
the appliance. See Section 3.D. for more information
regarding wall and enclosure construction.
CARODG36I, CARODG36IL
NOTICE:
Illustrations re
fl
ect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not
drawn to scale. Actual installation may vary due to individual design preference.