background image

outdoorrooms.com

4

SETTING UP YOUR BURNER

ATTENTION

Read and understand your Crystal Fire® Plus owner’s manual before

beginning burner hookups or using the device. 

DO NOT USE TEFLON TAPE OR PIPE DOPE ON FLARE FITTINGS.

3.

   For hard piped installations. Connect the gas supply line (

not included

) to the 

3/8” male flare fitting on the valve.

USE TWO WRENCHES TO ENSURE A GAS 

TIGHT CONNECTION.

   Run gas pipe up through the opening between the 2 base plates as shown in 

the image below.

!

!

A. GAS CONNECTIONS

  

See Crystal Fire

®

 Plus instructions for burner installation.

• 

 All gas connections were completed at the factory.

• 

 Check all connections for leaks. If needed, tighten connection with 2 wrenches 

and re-check for leaks.

•   Attach included control valve knob to control valve stem.

Содержание Kinney KN-1224

Страница 1: ...Installation Instructions for Kinney Fire Pit Table KN 1224 Kinney Fire Table outdoorrooms com...

Страница 2: ...CRYSTAL FIRE PLUS BURNER WITHOUT CONSULTING THE CRYSTAL FIRE PLUS OWNER S MANUAL CONTENTS 1 About Your Fire Table 2 a Required Tools outdoorrooms com 42507 REV C 01 16 20 1 b Included With Your Fire P...

Страница 3: ...c spark igniter installation 1 ABOUT YOUR FIRE TABLE Burner Cover 1 Fully Assembled Kinney Fire Table with CFP1224 Burner 1 A REQUIRED TOOLS B INCLUDED WITH YOUR FIRE PIT Bags of Glass Beads 2 Control...

Страница 4: ...ol valve and gas connection Exposed edges may be sharp use leather gloves when removing packaging and handling the base 2 CF SPARKER A UNPACKING B CF SPARKER INSTALLATION CONTROL PANEL WARNING Remove...

Страница 5: ...t included to the 3 8 male flare fitting on the valve USE TWO WRENCHES TO ENSURE A GAS TIGHT CONNECTION Run gas pipe up through the opening between the 2 base plates as shown in the image below A GAS...

Страница 6: ...back of the CF SPARKER If an orange wire is present DO NOT USE IT The orange wire is for Direct Spark Ignition system only Test system by pushing the button on the igniter Consult the troubleshooting...

Страница 7: ...Replace the access door ACCESS DOOR ATTENTION Over time the bearings in the door glides may require re greasing Any spray lubricant such as WD 40 may be used to lubricate drawer glides Perform annual...

Страница 8: ...TE CRYSTAL FIRE PLUS BURNER WITHOUT INCLUDED GLASS BEADS OR OTHER APPROVED FIRE MEDIA WARNING DO NOT OPERATE CRYSTAL FIRE PLUS BURNER WITH BURNER COVER IN PLACE 4 MISCELLANEOUS Fully shut off gas supp...

Страница 9: ...le surface C BURNER COVER STORAGE ATTENTION Use caution when removing and placing the burner cover as to not chip or damage the edge When not in use Burner cover can be conveniently stored within tabl...

Страница 10: ...opane cylinder slowly open cylinder valve Press and hold sparker button Verify an audible and visible spark is present within the ignition wind guard Gently press and turn control knob to LOW IGNITION...

Страница 11: ...ding lighting and operating instructions safety information and proper tightening of connections with two wrenches DO NOT ATTEMPT TO INSTALL CRYSTAL FIRE PLUS BURNER WITHOUT FIRST CONSULTING THE CRYST...

Страница 12: ...s made with pride in the USA Warranty Fire pit tables are covered under a 1 year manufacturer s warranty Please visit http www outdoorrooms com product registration to register your product 14400 Sout...

Отзывы: