8
www.outdoorrooms.com
42511 REV B : 03-16-2021
WIRING DIAGRAM - (CFP-ESO-CP)
CONTROL
MODULE
GAS CONTROL
VALVE
3.3 VDC+
3.3 VDC-
SENSOR/IGNITER
ESO
(NORMALLY CLOSED)
WALL SWITCH
(NORMALLY OPEN)
STANDARD
CONTROL
SWITCH
SUPPLY FROM GFCI
RECEPTACLE
110-120VAC