SERVICE PARTS

REPLACEMENT PARTS

KEY NO.

PART NO.

DESCRIPTION

1

30270032

Automatic Limit

2

30030006

Season Select Sw

itch

3

30030025

Speed Selector Switch

4

30030368

Continuous Speed Switch

5

30280021

Thermostat Indicator Light

6a

109412

8

9

Motor 1/3 HP 208/230 V for OFR15000

6b

10941290

Motor 1/3 HP 208/230 V for OFR18/20/23000

7

10940080

Element Assembly 5000 W, 240 V

8

10940081

Element Assembly 4500 W, 240 V

9

30274131

20 A Relay

10

30274132

30 A Relay

11

30280020

Manual Reset Limit

12

624665

Electronic Control (PC Board)

13

30300022

Transformer 240 V

14

30010010

Fiberglass Filter 20” x 20” x 1” (508 mm x 508 mm x 25 mm)

15a

10941291

S

ervice Blower Assembly for OFR15000

15b

10941292

S

ervice Blower Assembly for OFR1

8

/20/2

3

000

16

*

624664

Daughterboard (22.5 kW model)

17*

30274183

24 VAC, Relay, 30 A

* Item not shown.

6

1

3

4

6

9

10

11

12

13

14

2

5

7

8

15

Содержание Diablo OFR Series

Страница 1: ...condition and to premature furnace failure thus voiding the warranty Do not block the combustion air openings in the furnace Any blockage will result in improper overheat situation and may result in...

Страница 2: ...uired it will be indicated on the data label attached to the furnace 4 TEMPERATURE RISE Furnaces are shipped to operate at 0 20 5 mm W C 50 Pa external static pressure They are certified for operation...

Страница 3: ...ing spring or fall you may require less rapid response when the thermostat calls for heat When Mild is selected it takes more time to bring all the elements online When Cold is selected the heating el...

Страница 4: ...ly wires to the terminal block in the furnace NOTE If a OFR 120 kit will be used to supply an air cleaner and or humidifier a third neutral conductor must be brought into the furnace All wiring must c...

Страница 5: ...lubricated for life and needs no oiling FILTERS Size is 20 x 20 x 1 508 mm x 508 mm x 25 mm Should be inspected and replaced when dirty Ordinarily replacement is required twice per heating season and...

Страница 6: ...000 7 10940080 Element Assembly 5000 W 240 V 8 10940081 Element Assembly 4500 W 240 V 9 30274131 20 A Relay 10 30274132 30 A Relay 11 30280020 Manual Reset Limit 12 624665 Electronic Control PC Board...

Страница 7: ...NC Line voltage wiring UL AWM 1015 1230 600V 105 C VW 1 12AWG CSA TEW 600V 105 C FT1 12AWG Low voltage wiring same ratings as high voltage except 18AWG Critical Characteristic 1 If any of the origina...

Страница 8: ...COM NO HEAT 4 WHT 24Vdc PPL PPL BLK PPL BLK BLK SS TB2 NC Line voltage wiring UL AWM 1015 1230 600V 105 C VW 1 12AWG CSA TEW 600V 105 C FT1 12AWG Low voltage wiring same ratings as high voltage except...

Страница 9: ...UTEC 1139 610 P2 3 P2 2 P2 1 P1 4 P1 3 P1 2 P1 1 24V regulated RLY PWR2 Heater Logic HEAT6 IN HEAT5 IN HEAT6 HEAT5 PNK GRY PNK PPL PNK PPL PNK BLK BLK BLK PPL TB2 SS NC Line voltage wiring UL AWM 101...

Страница 10: ...efective 5 Must set thermostat much higher or lower than the desired house temperature Thermostat is not leveled or out of calibration 6 Not enough heat One or more defective elements or relays Season...

Отзывы: