The transmission aerial has a horizontal opening angle of 12° and the vertical
opening angle is 24°. The resulting sensor radar footprint can be found in the
example applications in Figures 3 and 4 and the table in Chapter 5.1.
A swivel mount allows easy, problem-free installation, even on unsuitable sur-
faces. The electrical connection is via a factory-assembled 12-pin angled con -
nector and a mounting socket.
The cable length between the radar sensor and the data logger can be up to
1000 metres (depending on the wire cross-section used).
The entire radar sensor – provided it is installed as described in these oper -
ating instructions – has a flood-proof design.
Transmission and
reception aerial cover
(Radom)
Swivel mount
Connecting cable
Fig. 2: OTT SVR radar sensor overview.
OTT SVR 100
Pressure probe
Fig. 3: Example application 1: OTT SVR
100 installed on a bridge.
The projection of the radar footprint on the
water surface is elliptical.
In the example shown, the water level is
determined using a pressure probe.
7
Содержание SVR 100
Страница 1: ...English Operating Instructions Surface Velocity Radar OTT SVR 100...
Страница 2: ...We reserve the right to make technical improvements...
Страница 14: ...Hexagon bolt A Hexagon bolt B Wall bracket Housing bracket Fig 10 OTT SVR 100 Installation of swivel mount 14...
Страница 15: ...20 a 60 Recommended a 30 6 0 20 a 30 0 20 45 30 60 Fig 11 Adjusting the sensor tilt angle on the OTT SVR 100 15...