10.1.10
Icon
You can select an Icon for the measurement. The icon will show on the dashboard and measurement list.
Press “Change” to choose an image in the computer or take a picture. Remember the icon is small and
cannot show detailed information.
10.1.11
Picture
A picture of the sensor is shown to the right of the sensor information. LinkComm includes pictures for
many common sensors and Measurement Types. Press “Change” to choose an image in the computer or
take a picture to use.
10.1.12
Defaults
Press the Defaults control to set all the settings for a specific measurement to default values. Note the
default measurement type is SDI-12. Setting defaults will also set the metadata (picture, icon, description
etc.) to default values.
10.2
Schedule
10.2.1
Measurement Interval
Measurement interval is simply the time between scheduled measurements. See Measurement Time.
10.2.2
Measurement Time
Measurement interval and time dictate when the measurement will be made. The interval controls how
often the measurement is made, and the time controls when the measurement is started.
Example 1 (The measurement is logged every 10 minutes at 0 seconds past the minute): time
00:00:00 interval 00:10:00
00:10:00 data measured and logged
00:20:00 data measured and logged
00:30:00 data measured and logged
and every 10 minutes afterwards
…
Example 2 (The measurement is taken and logged every 5 minutes at 30 seconds past the
minute): time 00:00:30 interval 00:05:00
00:00:30 data measured and logged
00:05:30 data measured and logged
00:10:30 data measured and logged
10.2.3
Averaging Time, Sampling Interval, Subsamples, and Results
XLink can collect multiple samples and average them in order to produce a single result. Averaging is
useful for measuring changing conditions, such as wind and water level. For example, correctly measuring
the level of choppy water requires that wave action be canceled. That can be accomplished by averaging
over several minutes.