The Port Status LEDs, Wall Mounting Kit 

LED Indicators 

The diagnostic LEDs located on the front panel of the industrial switch provide real-time information of system and optional status. The following 

table provides the description of the LED status and their meanings for the switch. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED 

State 

Indication 

PWR1 
PWR2 

Steady 

Power on. 

Off 

Power off. 

FAULT 

Steady 

Power input 1 or 2 is inactive   

Off 

Power 1 & Power 2 are both active or 

no power inputs 

P1~P8 

LNK/ACT 

(Green) 

Steady 

Connected to network   

Flashing 

Networking is active 

P1~P8 

Duplex 

(Yellow) 

Steady 

Ethernet port full duplex   

Flashing 

Collision of packet occurs   

Off 

Ethernet  port  half  duplex  or  not 

connected to network   

P1~P8 

FWD 

Steady 

A  powered  device  is  connected 

utilizing  Power  over  Ethernet  on  the 

port   

Off 

No  device  is  connected  or  power 

forwarding 

P9, P10 

(RJ-45) 

Upper 

LED

 

Steady

 

Connected to network 

Flashing

 

Networking is active 

Off

 

Not connected to network 

Lower 
LED

 

Steady

 

The port is operating at speed of 

1000M 

Off

 

The port is disconnected or not 

operating at speed of 1000M 

P9, P10 

Link/Active 

Steady

 

SFP port is linking 

Flashing

 

Data is transmitting or receiving 

Off

 

Not connected to network 