Страница 2: ...hearing aid models miniRITE R miniRITE T FW 1 3 Oticon More 1 miniRITE R GTIN 05714464042685 Oticon More 2 miniRITE R GTIN 05714464042678 Oticon More 3 miniRITE R GTIN 05714464042661 Oticon More 1 miniRITE T GTIN 05714464042685 Oticon More 2 miniRITE T GTIN 05714464042678 Oticon More 3 miniRITE T GTIN 05714464042661 ...

Страница 3: ... PX 1 miniRITE R GTIN 05714464042920 Oticon Play PX 2 miniRITE R GTIN 05714464042913 Oticon Play PX 1 miniRITE T GTIN 05714464042920 Oticon Play PX 2 miniRITE T GTIN 05714464042913 The following speakers are available for the above model Speaker 60 Speaker 85 Speaker 100 Power Instrument Power flex mould speaker 100 Power Instrument Power flex mould speaker 105 Power Instrument MicroShell 60 Micro...

Страница 4: ...onal questions contact your hearing care professional A hearing care professional hearing aid professional audiologist ENT ear nose and throat doctor and hearing aid dispenser is a person who is appropriately educated and has proven competency in professionally assessing hearing selecting fitting and delivering hearing instruments and rehabilitation care to persons with hearing loss The education ...

Страница 5: ......

Страница 6: ...e professional responsible for adjusting the hearing aid Intended user group Adults and children older than 36 months Use environment Indoor and outdoor Contraindications Not suitable for infants below 36 months Users of active implants must pay special attention when using the hearing aid For more information read the Warnings section Clinical benefits The hearing aid is designed to provide bette...

Страница 7: ...IMPORTANT NOTICE The hearing aid amplification is uniquely adjusted and optimised to your personal hearing capabilities during the hearing aid fitting performed by your hearing care professional ...

Страница 8: ...s ON OFF 16 Low battery indication 19 Identify left and right hearing aid 20 How to replace the disposable battery size 312 22 Put on hearing aid 24 Daily use Cleaning 26 Replace standard earpieces 28 ProWax miniFit filter 30 Clean customised earpieces 32 Replace ProWax filter 33 Hearing aid storage 34 Change volume 35 Change program 36 ...

Страница 9: ... iPad and iPod 42 Use your hearing aid with Android devices 43 Pairing and compatibility 44 Wireless accessories and other options 45 Tinnitus Tinnitus SoundSupport optional 48 Sound options and volume adjustments 50 Limitation on use time 52 Tinnitus SoundSupport warnings 55 Warnings General warnings 56 ...

Страница 10: ...le of contents More info Troubleshooting 64 Water dust resistant IP68 68 Conditions of use 69 Technical information 72 Warranty 79 Your individual hearing aid settings 80 Sound and LED light indicators 83 ...

Страница 11: ...hearing aid speaker and earpiece Rechargeable battery miniRITE R only Wax filter Speaker Ear grip Push button Upper part Lower part Microphones LED light Nail grip miniRITE T only Battery drawer miniRITE T only ...

Страница 12: ...12 About Getting started Daily use Options Tinnitus Warnings More info 60 85 100 100 105 60 85 Standard speakers The hearing aid uses one of the following speakers Power flex mould speakers MicroShell ...

Страница 13: ...ioTherm LiteTip Note For details on replacing the dome see the Replace standard earpieces section VarioTherm is a registered trademark of Dreve Power dome Grip Tip Available in small and large left and right with or without vent OpenBass dome Bass dome double vent Only as OpenBass dome for speaker 60 6 mm 5 mm 8 mm 10 mm 12 mm Dome sizes ...

Страница 14: ... charged hearing aids If your hearing aid s battery is completely drained the normal charging time is 3 hours 1 hour 0 5 hour Fully charged 50 charged 25 charged When the battery is fully charged the charging process stops automatically Charging time may vary depending on the remaining capacity of the battery and between the left right hearing aid For instructions on how to use your charger see th...

Страница 15: ... this performance Rechargeable battery miniRITE R only If your rechargeable hearing aids do not perform for a full day you may need to have the rechargeable battery replaced If so contact your hearing care professional If your hearing aids run out of battery ensure you recharge them by placing them in the charger Be aware that restarting the hearing aids does not give you more usage time ...

Страница 16: ... LED light blinks GREEN twice confirming that it is ready for use Depending on your hearing aid settings you may also hear a start up jingle Your hearing aid automatically turns OFF and starts charging when placed in the charger The hearing aid LED light turns ORANGE IMPORTANT NOTICE If applicable ensure that your charger is powered or that the charger s built in battery is charged when the hearin...

Страница 17: ... Release the push button and wait until the hearing aid LED light blinks GREEN twice The hearing aid is now turned ON To turn OFF Press and hold the lower part of the push button for approximately three seconds until the hearing aid LED light turns ORANGE The hearing aid plays four descending tones Release the push button and the hearing aid is turned OFF For information regarding tones see the So...

Страница 18: ...y drawer is used to turn the hearing aids ON and OFF To save battery life make sure your hearing aids are switched OFF when you are not wearing them To perform a quick reset of hearing aid settings open and close the battery drawer Turn ON Close the battery drawer with the battery in place Turn OFF Open the battery drawer ...

Страница 19: ...rs before the hearing aid runs out of battery At this point you may continue to stream audio for approximately one hour miniRITE T When the battery is running low you hear three alternate beeps This gives you approximately 15 minutes before the hearing aid runs out of battery At this point Bluetooth connectivity is turned OFF Three alternate beeps The battery is running low Four descending tones T...

Страница 20: ... they may be programmed differently You can find left right colour indicators on the hearing aid itself and on 60 and 85 speakers as shown Indicator markings either L or R can also be found on 100 speakers and customised earpieces For 105 speakers the indicator is found on the earpiece A RED indicator marks the RIGHT hearing aid A BLUE indicator marks the LEFT hearing aid miniRITE R ...

Страница 21: ...21 A RED indicator marks the RIGHT hearing aid A BLUE indicator marks the LEFT hearing aid miniRITE T ...

Страница 22: ...w to replace the disposable battery size 312 miniRITE T only 2 Uncover 3 Insert Fully open the battery drawer and remove the battery Remove the sticky label from the side of the new battery Insert the new battery into the battery drawer with the side facing upwards 1 Remove ...

Страница 23: ...ttery drawer You may hear a jingle through the earpiece You can use the MultiTool to change the battery Use the magnetic end to remove and insert batteries The MultiTool is provided by your hearing care professional 4 Close Tip ...

Страница 24: ...attached Ensure you only use parts designed for your hearing aid Hold the bend of the speaker wire between your thumb and index finger The earpiece should point towards the opening of the ear canal Gently push the earpiece into your ear canal until the speaker wire sits close to your head If the speaker has an ear grip place it in the ear so it follows the contour of the ear Step 1 Step 2 Step 3 ...

Страница 25: ......

Страница 26: ...rush and wire loop for cleaning and removing earwax If you need a new MultiTool contact your hearing care professional Brush Wire loop Magnet IMPORTANT NOTICE The MultiTool has a built in magnet Keep the MultiTool at least 30 centimetres 1 foot away from credit cards and other magnetically sensitive devices ...

Страница 27: ...ully brush debris away from the openings and the surface around the openings Ensure that you do not forcefully squeeze parts of the MultiTool into the microphone openings This may damage the hearing aid IMPORTANT NOTICE To clean the hearing aid use a soft dry cloth The hearing aid must never be washed or immersed in water or other liquids Microphone openings ...

Страница 28: ...arpiece dome and Grip Tip If the earpiece is filled with earwax replace it with a new one Grip Tip needs to be replaced at least once a month Hold on to the speaker and pull off the earpiece Insert the speaker exactly into the middle of the earpiece to get a secure fit Push firmly to ensure that the earpiece is securely fastened Step 1 Step 2 Step 3 ...

Страница 29: ...29 IMPORTANT NOTICE If the earpiece is not on the speaker when removed from the ear the earpiece may still be in the ear canal For further instructions consult your hearing care professional ...

Страница 30: ...essional ProWax miniFit filter The speaker has a white wax filter attached to the end where the earpiece is attached The wax filter keeps earwax and debris from damaging the speaker Ensure you replace the filter when clogged or if the hearing aid does not sound normal Alternatively contact your hearing care professional Ensure you remove the earpiece from the speaker before replacing the wax filte...

Страница 31: ...th the new wax filter Insert the empty pin into the wax filter in the speaker and pull it out Insert the new wax filter using the other pin remove the tool and throw it out 1 Tool New filter New filter Empty pin Old filter Final Note If you use a mould or LiteTip your hearing care professional must replace the wax filter in the speaker ...

Страница 32: ...ris from damaging the speaker Ensure you replace the filter when clogged or if the hearing aid does not sound normal Alternatively contact your hearing care professional Clean the vent by inserting the brush through the hole twisting it slightly Vent Note If you use a mould or LiteTip your hearing care professional must replace the wax filter in the speaker VarioTherm Micro mould and LiteTip do no...

Страница 33: ...from the shell The tool has two pins one empty for removal and one with the new wax filter Insert the empty pin into the wax filter in the earpiece and pull it out Insert the new wax filter using the other pin remove the tool and throw it out 1 Tool New filter Old filter ...

Страница 34: ...ng aid in the sun in front of a window or in a car even if the hearing aid is in the charger Long term storage Before you put away or store the hearing aid for a prolonged period of time more than 14 days ensure you first fully charge the hearing aid and then turn it OFF This way the battery can be charged again Note To protect the rechargeable battery it is necessary that you fully charge the hea...

Страница 35: ...me you hear a beep For information regarding button press times see the table General settings overview for your hearing aid in the Your individual hearing aid settings section at the end of this booklet MAXIMUM START UP VOLUME MINIMUM Press button to increase volume Press button to decrease volume ...

Страница 36: ...hearing care professional Depending on the program you choose 1 2 3 or 4 you hear one to four tones For information regarding tones see the Sound and LED light indicators section For information regarding button press times see the table General settings overview for your hearing aid in the Your individual hearing aid settings section at the end of this booklet ...

Страница 37: ...e program cycle switches one program forward when the upper part of the push button is pressed for example program 1 to 2 or program 4 to 1 If the lower part of the push button is pressed the program cycle goes backward for example 2 to 1 or program 1 to 4 ...

Страница 38: ...and functioning Be aware that pressing the push button on one hearing aid activates Flight mode on both hearing aids For more information about sounds and lights see the Sound and LED light indicators section To activate and deactivate Press and hold the lower part of the push button for seven seconds Four descending tones a short jingle and an LED light pattern confirm your action miniRITE R ...

Страница 39: ...nd deactivate Press and hold either end of the push button for at least seven seconds A jingle and an LED light pattern confirm your action Opening and closing the battery drawer also deactivates Flight mode miniRITE T ...

Страница 40: ...ollowing optional devices app Oticon ON ConnectClip Remote Control 3 0 How to unmute your hearing aids You can unmute your hearing aids by using one of the optional devices app or by applying a short press to the upper or lower part of the push button on the hearing aids miniRITE T only You can also mute your hearing aids by pressing either end of the push button for four seconds ...

Страница 41: ...41 IMPORTANT NOTICE Do not use the mute function as an OFF button as the hearing aid is still using battery power in this mode ...

Страница 42: ...e products contact your hearing care professional Use of the Made for Apple badge means that an accessory has been designed to connect specifically to the Apple products identified in the badge and has been certified by the developer to meet Apple performance standards Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards Please note that ...

Страница 43: ...pport Audio Streaming for Hearing Aids ASHA and allow for direct streaming from selected Android devices Oticon ON can be used to control your hearing aids from your mobile device For assistance in using your hearing aid with Android devices contact your hearing care professional ...

Страница 44: ...e info Pairing and compatibility For instructions on how to pair your hearing aid with iPhone iPad iPod touch or Android devices visit www oticon global pairing For a list of compatible iPhone iPad iPod touch and Android devices visit www oticon global compatibility ...

Страница 45: ...at can be used as remote microphone and hands free headset when paired to your mobile phone Phone Adapter 2 0 A device that when used together with hearing aids and ConnectClip lets you communicate hands free via a landline phone TV Adapter 3 0 A device that streams sound from a TV or electronic audio device to your hearing aids Remote Control 3 0 A device that lets you change program adjust volum...

Страница 46: ... Ensure that you only download and install Oticon ON from the official app stores Telecoil Telecoil can help you hear better when using a phone with a built in loop or when in buildings with teleloop systems such as theatres places of worship or lecture rooms This symbol is shown wherever a teleloop has been installed Apple the Apple logo iPhone iPad and iPod touch are trademarks of Apple Inc regi...

Страница 47: ......

Страница 48: ...om tinnitus as part of a tinnitus management program The target population is the adult population over 18 years of age Tinnitus SoundSupport is targeted to licenced hearing care professionals audiologists hearing aid specialists or otolaryngologists who are familiar with the evaluation and treatment of tinnitus and hearing loss Fitting of Tinnitus SoundSupport must be done by a hearing care profe...

Страница 49: ... help manage tinnitus Your hearing care professional will also be able to offer the appropriate follow up care It is important to follow his her advice and directions regarding such care Prescription use only Good health practice requires that the person reporting tinnitus has a medical evaluation by a licenced ear physician before using a sound generator The purpose of such an evaluation is to en...

Страница 50: ... you can select your preferred sound s Tinnitus SoundSupport programs Together with your hearing care professional you decide for which programs you may want to have Tinnitus SoundSupport activated The sound generator can be activated in up to four different programs Mute If you are in a program for which Tinnitus SoundSupport is activated the mute functionality only mutes the environmental sounds...

Страница 51: ... for the tinnitus relief sound Your hearing care professional sets the volume control for the sound generator in one of two ways A Change volume in each ear separately or B Change volume in both ears simultaneously For more information about volume adjustments with Tinnitus SoundSupport see the table Tinnitus SoundSupport settings overview for your hearing aid in the Your individual hearing aid se...

Страница 52: ...d for a prolonged period of time Your hearing care professional will advise you of the maximum amount of time per day you should use Tinnitus SoundSupport It should never be used at uncomfortable levels See the table Tinnitus SoundSupport Limitation on use in the Your individual hearing aid settings section at the end of this booklet to learn how many hours per day you can safely use the relief so...

Страница 53: ...oundSupport will decrease as you increase the level above 80 dB A SPL The fitting software automatically displays a warning when the hearing aid exceeds 80 dB A SPL For more information in the fitting software next to the tinnitus fitting graph see the Max wearing time indicator The volume control is deactivated By default the volume control for the sound generator is deactivated in the hearing ai...

Страница 54: ...n be listened to at levels that may cause hearing damage The Max wearing time table in the fitting software displays the number of hours the patient can safely use Tinnitus SoundSupport 1 Be aware and note down the maximum wearing time for each program for which Tinnitus SoundSupport is activated 2 Ensure you write those values on the Tinnitus SoundSupport Limitation on use table in the back of th...

Страница 55: ...heart palpitations or possible skin irritation at the point of contact with the device you should immediately discontinue use of the device and consult a medical audiology or other hearing care professional As with any device misuse of the sound generator feature may cause potentially harmful effects Care should be taken to prevent unauthorised use and to keep the device out of reach of children a...

Страница 56: ...mpairment resulting from organic conditions Hearing aids are only a part of hearing habilitation and may need to be supplemented by auditory training and instruction in lipreading Furthermore note that in most cases infrequent use of a hearing aid does not permit a user to attain full benefit from it miniRITE R only Only charge the hearing aids with a designated charger Other chargers risk destroy...

Страница 57: ...h of children and anyone who might swallow these items or otherwise cause injury to themselves If a battery hearing aid or small part is swallowed see a doctor immediately miniRITE T only Batteries have occasionally been mistaken for pills Therefore check your medicine carefully before swallowing any pills Battery use miniRITE T only Always use batteries recommended by your hearing care profession...

Страница 58: ... are handled Fatality hazards and risk of swallowing lithium ion batteries or placing them in the ear or nose miniRITE R only Never swallow lithium ion batteries nor place them in the ear or the nose as this may lead to serious injury or death in as little as two hours This can be due to chemical burns which can permanently damage the nose or ear or potentially lead to perforation of the inner org...

Страница 59: ...d is left on your skin If you experience skin irritation consult your doctor For further handling instructions of your hearing instrument consult your hearing care professional The safety of recharging batteries using a USB connector is determined by the external signal source When connected to external equipment plugged into a power socket this equipment must comply with IEC 62368 1 or equivalent...

Страница 60: ... implantable device for information about the risk of disturbance The Autophone magnet or MultiTool which has a built in magnet should be kept more than 30 centimetres 1 foot away from the implant e g do not carry it in your breast pocket Follow the guidelines recommended by the manufacturers of implantable defibrillators and pacemakers regarding their use with magnets Cochlear implants If you are...

Страница 61: ...eft inside a parked car in the sun The hearing aid must not be dried in microwave ovens or other ovens The chemicals in cosmetics hairspray perfume aftershave lotion sunscreen lotion and insect repellent can damage the hearing aid Always remove your hearing aid before applying such products and allow time to dry before use Connection to external equipment The safety of the hearing aids when connec...

Страница 62: ...allergenic materials used in hearing aids may in rare cases cause a skin irritation or other side effects If these conditions occur seek consultation with a physician Use on aircraft Your hearing aids have Bluetooth wireless technology On board an aircraft the hearing aids must be put into Flight mode to deactivate Bluetooth unless Bluetooth is permitted by the flight personnel Use of third party ...

Страница 63: ...ards Electromagnetic interference may occur in the vicinity of equipment with the symbol to the left Portable and mobile RF radio frequency communications equipment can affect the performance of your hearing aids If your hearing aids are affected by electromagnetic interference move away from the source to reduce the interference ...

Страница 64: ...rophone muted Intermittent or reduced sound Clogged sound outlet Moisture Squealing noise Hearing aid earpiece incorrectly inserted Earwax accumulated in ear canal Beeping If your hearing aid plays eight beeps four times consecutively your hearing aid needs a microphone service check Pairing issue with smartphone Bluetooth connection failed Only one hearing aid is paired Troubleshooting miniRITE R...

Страница 65: ...lace wax filter dome or Grip Tip Gently wipe the hearing aid and let it dry Re insert the earpiece Have ear canal examined by your doctor Contact your hearing care professional 1 Unpair your hearing aid 2 On your phone turn Bluetooth OFF and ON again 3 Turn the hearing aid OFF and then turn it back ON 4 Pair your hearing aid again For guidance visit www oticon global pairing Continues on next page...

Страница 66: ...cold Charging is incomplete The charger has stopped charging to protect the battery The hearing aid is incorrectly seated in the charger The hearing aid LED light blinks GREEN when the hearing aid is placed in the charger Hearing aid has not been in use for a prolonged period of time The hearing aid LED light blinks ORANGE when the hearing aid is placed in the charger System error Troubleshooting ...

Страница 67: ...er This completes the charging within approximately 15 minutes Check the charging ports for foreign objects Depending on how depleted the battery in the hearing aid is the hearing aid automatically resumes normal charging mode after a timeframe of up to 10 minutes Ensure you leave the hearing aids in the charger during this process Contact your hearing care professional Note If none of the above s...

Страница 68: ...means you do not have to worry about your hearing aid getting wet when it rains or if it comes into contact with sweat Before charging the hearing aid make sure to wipe off any moisture Should your hearing aid come into contact with water and stop working gently wipe off any water and let the hearing aid dry IMPORTANT NOTICE Do not wear your hearing aid while showering or participating in water ac...

Страница 69: ... Transportation and storage conditions Temperature and humidity shall not exceed the below limits for extended periods during transportation and storage Transportation Temperature 20 C to 60 C 4 F to 140 F Humidity 5 to 93 relative humidity non condensing Atmospheric pressure 700 hPa to 1060 hPa Storage Temperature 20 C to 30 C 4 F to 86 F Humidity 5 to 93 relative humidity non condensing Atmosphe...

Страница 70: ...o 1060 hPa Transportation and storage conditions Temperature and humidity shall not exceed the below limits for extended periods during transportation and storage Transportation Temperature 25 C to 60 C 13 F to 140 F Humidity 5 to 93 relative humidity non condensing Atmospheric pressure 700 hPa to 1060 hPa Storage Temperature 25 C to 60 C 13 F to 140 F Humidity 5 to 93 relative humidity non conden...

Страница 71: ......

Страница 72: ...ays below 15 nW typically below 40 dBμA m 12 20 dBμA ft at 10 metres 33 feet distance The hearing aid also contains a radio transceiver using Bluetooth Low Energy technology and a proprietary short range radio technology both operating at ISM band 2 4 GHz The radio transmitter is weak and always below 9 mW equal to 9 6 dBm in total radiated power The hearing aid complies with international standar...

Страница 73: ...73 Due to the limited space available on the hearing aid relevant approval markings can be found in this booklet Additional information can be found in the Technical Data Sheet on www oticon global ...

Страница 74: ...rer declares that this hearing aid is in compliance with the essential requirements and other relevant provisions of Directive 2014 53 EU This medical device complies with Medical Device Regulation EU 2017 745 Declaration of Conformity is available from the headquarters Oticon A S Kongebakken 9 DK 2765 Smørum Denmark www oticon global doc SBO Hearing A S Denmark ...

Страница 75: ...batteries according to local regulations Hearing aid users can also return electronic waste to their hearing care professional for disposal Electronic equipment covered by Directive 2012 19 EU on waste and electrical equipment WEEE Regulatory Compliance Mark RCM The device complies with electrical safety EMC and radio spectrum requirements for devices supplied to the Australian or New Zealand mark...

Страница 76: ...op This logo incorporates the universal symbol for hearing assistance The T signifies that a hearing loop is installed Radio Frequency RF transmitter Your hearing aid contains an RF transmitter GTIN Global Trade Item Number A globally unique 14 digit number used to identify medical device products including medical device software GTIN in this booklet is related to medical device firmware FW GTIN ...

Страница 77: ...er s serial number so that a specific medical device can be identified Medical Device The device is a medical device Battery recycling symbol Li ion battery recycling symbol Temperature limit Indicates the temperature limits to which the medical device can be safely exposed Humidity limitation Indicates the range of humidity to which the medical device can be safely exposed Radio Frequency Identif...

Страница 78: ...ar damage due to foreign objects entering the device or incorrect adjustments are NOT covered by the international warranty and may void it The above international warranty does not affect any legal rights that you might have under applicable national legislation governing the sale of consumer goods in the country where you have bought your device Your hearing care professional may also have issue...

Страница 79: ...______________________________________ Hearing care professional s phone _________________________________________ Purchase date _________________________________________________________ Warranty period ________________ Month _________________________________ Model left _____________________ Serial no _______________________________ Model right ____________________ Serial no ______________________...

Страница 80: ...ofessional Tinnitus SoundSupport Limitation on use n No limitation on use Program Start up volume Tinnitus Max volume Tinnitus n 1 Max _______ hours per day Max _______ hours per day n 2 Max _______ hours per day Max _______ hours per day n 3 Max _______ hours per day Max _______ hours per day n 4 Max _______ hours per day Max _______ hours per day ...

Страница 81: ...n repeatedly until you reach your desired level n B How to change Tinnitus SoundSupport volume in both ears simultaneously You can use one hearing aid to increase decrease the sound in both hearing aids When changing the volume in one hearing aid the volume on the other hearing aid follows To increase volume use a short press on the upper part of the push button repeatedly To decrease volume use a...

Страница 82: ...Yes n No Change program n Yes n No n Short press n Short press n Long press n Long press Volume control indicators n ON n OFF Beeps at min max volume n ON n OFF n ON n OFF Beeps when changing volume n ON n OFF n ON n OFF Beeps at start up volume n ON n OFF Battery indicators n ON n OFF Low battery warning n ON n OFF To be filled out by your hearing care professional ...

Страница 83: ...or light indicators on your charger see the charger s instructions for use Your hearing care professional can set sound and LED light indicators to match your preferences Program nSound nLED light When to use 1 1 tone 2 2 tones 3 3 tones 4 4 tones Short GREEN blink LED light blinks continuously or is repeated three times with short pauses Continues on next page ...

Страница 84: ...ght comments ON nJingle n Shown once OFF miniRITE R only n 4 descending tones n Volume Sound LED light Start up volume n2 beeps n Minimum maximum volume n3 beeps n Volume up down n1 beep n Mute n Continuous or repeated three times Long GREEN blink Short GREEN blink Long ORANGE blink Short ORANGE blink ...

Страница 85: ... mode activated miniRITE R only 4 descending tones short jingle Flight mode deactivated miniRITE R only 4 descending tones short jingle Flight mode activated miniRITE T only Short jingle Flight mode deactivated miniRITE T only Short jingle Long GREEN blink Short GREEN blink Long ORANGE blink Short ORANGE blink Only available when three time repetition is selected Continues on next page ...

Страница 86: ... 3 alternate beeps n Continuously blinking Battery shut down 4 descending tones Microphone service check needed 8 beeps repeated 4 times n Repeated four times The hearing aid LED light does not turn ON when the hearing aid is placed in the charger miniRITE R only Turned OFF See the Trouble shooting section 233859UK 2021 11 24 v2 ...

Страница 87: ...aid is placed in the charger miniRITE R only Continuously blinking See the Troubleshooting section The hearing aid LED light blinks GREEN when the hearing aid is placed in the charger miniRITE R only Continuously blinking See the Troubleshooting section Long GREEN blink Short GREEN blink Long ORANGE blink Short ORANGE blink ...

Страница 88: ...0000233859000001 233859UK 2021 11 24 v2 Oticon More Firmware 1 3 Oticon Zircon Oticon Play PX Firmware 1 1 ...