background image

14

changing batteries

The correct battery size is 10. 

Batteries perform differently, so ask your Hearing Care Professional for assistance  

in choosing a high, quality battery for your hearing instruments. 

A worn battery should be removed immediately and disposed of according to local 

regulations. 

You will hear 2 beeps when it is time to change the battery.  

This pre-warning will be repeated in moderate intervals until  

the battery expires. The battery may expire shortly after a 

pre-warning or within 2–3 hours, depending on battery  

capabilities and individual hearing loss.

 

When the battery is about to die, you will hear 4 beeps indicating 

that the instrument will shortly turn off.

Replace the battery.

Содержание Intiga i

Страница 1: ...Instructions for use IIC Invisible In Canal...

Страница 2: ...earing Care Professional Various functions may be configured to your hearing instruments to meet your needs The actual configuration of your instruments are marked ticked off by your Hearing Care Prof...

Страница 3: ...Indications for Use The hearing instruments are intended to amplify and transmit sound to the ear and hereby compensate for mild to moderate impaired hearing...

Страница 4: ......

Страница 5: ...OFF 16 Left Right ear marking 17 Inserting your hearing instruments 18 Removing your hearing instruments 20 Caring for your hearing instruments 21 Wax Protection System 24 Microphone Protection System...

Страница 6: ...about the use and handling of your hearing instru ments and batteries Please familiarise yourself with the entire contents of this booklet before using your hearing instruments International Warranty...

Страница 7: ...w Intigai Battery size 10 Microphone opening Battery door with nail grip Right left side and up indicator Sound outlet Wax protection system Ventilation opening Pull out string Pull out string 7 Venti...

Страница 8: ...your hearing instruments as incorrect wrongful usage could cause permanent damage to their hearing Choking hazards Hearing instruments their parts and batteries are not toys and should be kept out of...

Страница 9: ...d be accidently swallowed If a battery or hearing instrument is swallowed see a doctor immediately Battery use Always use batteries recommended by your Hearing Care Professional Low quality batteries...

Страница 10: ...ool has a built in magnet If you have an implantable device such as a pacemaker or defibrillator the MultiTool should not be carried in a breast pocket or near to the chest Explosives The power source...

Страница 11: ...allergenic materials used in hearing instruments may in rare cases cause skin irritation or other unusual conditions Please consult a physician if these conditions occur Interference Your hearing ins...

Страница 12: ...ent is equipped with a ProWax wax protection system follow the directions specified in the section How to change Wax filter If you are in any doubt about the use or replacement of your wax protection...

Страница 13: ...attery compartment Your hearing instruments will begin functioning when the battery door is closed It will take a few seconds until sound is produced A jingle is played during the start up process Aft...

Страница 14: ...d disposed of according to local regulations You will hear 2 beeps when it is time to change the battery This pre warning will be repeated in moderate intervals until the battery expires The battery m...

Страница 15: ...e inserted by using the magnetic end of the MultiTool Ensure that the positive end faces the positive sign printed on the battery door Close the battery door Any moisture on the battery surface should...

Страница 16: ...s operating Turn off your hearing instruments by opening the battery door slightly until a click is felt Make sure that the battery door is fully opened to turn off the instrument completely To preser...

Страница 17: ...differently from your right For this reason it is important to distinguish between the left hear ing instrument and the right In order to easily distinguish the left ear from the right ear instrument...

Страница 18: ...oured dot on the shell should face up 2 Gently pull your ear back and push the hearing instrument into the ear canal 3 Use the tip of your finger to gently push the instrument 4 Continue to push gentl...

Страница 19: ...19 step3_inserting IIC in the ear 2 3 4...

Страница 20: ...out string Gently pull the instrument from the ear canal It may be helpful to gently pull your ear back as was done when inserting the instrument IMPORTANT NOTICE DO NOT use the battery door as a han...

Страница 21: ...your Hearing Care Professional for assistance When handling your hearing instruments keep them on a soft surface to avoid damage if you drop it Before retiring at night Make sure there is no earwax i...

Страница 22: ...should be used to ensure optimal care and performance of your hearing instruments Replace the brush when necessary by pulling the used brush out of the MultiTool and inserting a new one Be sure the ne...

Страница 23: ...rough the hole while twisting it slightly Replace the brush when necessary by pulling the used brush out of the MultiTool and inserting a new one Be sure the new brush is pressed firmly into the handl...

Страница 24: ...r liquids Wax Protection System ProWax If the instrument is equipped with a ProWax wax protection system follow the directions specified in the section How to change Wax filter If you are in any doubt...

Страница 25: ...arms one with the removal tool A and one with the new filter B 2 Push the removal arm into the existing wax filter 3 Remove the used filter from the hearing instrument and push the new filter sitt in...

Страница 26: ...ew T Cap B 2 Using the removal end place it under the T Cap edge and push it under the top edge of the used T Cap 3 Lift the used T Cap up and out 4 Using the other end of the tool insert the new T Ca...

Страница 27: ...27 2 3 4...

Страница 28: ......

Страница 29: ...erformance Using an anti humidity kit can help to avoid these problems and may even extend the life of your hearing instruments Consult your Hearing Care Professional for further information The chemi...

Страница 30: ...nstruments Do not use hearing instruments in ears with excessive earwax accumulation or infection Use proper preventive care and maintenance to ensure reliability and safe performance Do not share you...

Страница 31: ...e many background sounds and try to identify each sound Bear in mind that some sounds will seem different or unusual to you You may have to learn to re identify them Note that in time you will become...

Страница 32: ...ech sounds you will hear speech much clearer 3 Listen to radio or TV When listening to the TV or the radio start out by listening to news commentators since they usually speak clearly then try other T...

Страница 33: ...uments all day long The best way to ensure better hearing is to practice listening until you can wear your hearing instruments comfortably all day You will not get the full benefit of the hearing inst...

Страница 34: ...or reduced sound Clogged sound outlet Clogged microphone inlet Moisture Worn out battery Squealing noise Hearing instruments inserted improperly Earwax accumulated in ear canal If none of the above so...

Страница 35: ...n the microphone inlet or change T Cap pg 26 Clean sound outlet or change ProWax pg 24 Clean the microphone inlet or change T Cap pg 26 Wipe battery and instrument with dry cloth pg 29 Change battery...

Страница 36: ...d mobile phone can be predicted by adding the rating for the hearing aid immunity to the rating for the mobile phone emissions For example the sum of a hearing aid rating of 2 M2 and a telephone ratin...

Страница 37: ...ore please try this hearing instrument with your mobile phone or if you are purchasing a new phone be sure to try it with your hearing instrument prior to your purchase For additional guidance please...

Страница 38: ...exposure to corrosive conditions physical changes in the ear damage due to foreign objects entering the device or incorrect adjustments are NOT covered by the limited warranty and may void it The abo...

Страница 39: ...39 Warranty Certificate Name of Owner Dispenser Dispenser Address Dispenser Phone Purchase Date Warranty Period Month Model Left Serial no Model Right Serial no Battery Size 10...

Страница 40: ...al regulations 0543 Hereby Oticon A S declares these hearing instruments to be in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Declaration of conform...

Страница 41: ...41 Settings overview for your hearing instruments Hearing Instrument Left Battery Indicator Right n On n Off Low battery warning n On n Off...

Страница 42: ...119727UK 12 11...

Страница 43: ...119727UK 12 11...

Страница 44: ...People First People First is our promise to empower people to communicate freely interact naturally and participate actively...

Отзывы: