background image

FTD110DB-XXR3 Series Installation & Operation Manual 

 

www.ot-systems.com

 

 

 

 

14 

 

(6)  Specifications 

MODELS* 

 

PARAMETERS

 

FTD110DB-SSR3SA 

FTD110DB-SSR3 

(Single-Mode)

 

FTD110DB-SSR3LSA 

FTD110DB-SSR3L 

(Single-Mode) 

FTD110DB-SMR3SA 

FTD110DB-SMR3 

(Multi-Mode)

 

OPTICAL 

 

 

 

No. of Fiber / Connector 

3 / ST(or FC) 

3 / ST(or FC) 

3 / ST(or FC) 

Wavelength 

1310/1550 nm 

1550/1310 nm 

1310/1550 nm 

Optical Power Budget 

17 dB 

24 dB 

23 dB 

Max Distance 

40 km 

60 km 

4 km 

ELECTRICAL VIDEO 

 

Channel / Connector 

3 / BNC 

System 

PAL, NTSC, SECAM 

Bandwidth 

  6.0 MHz 

Input/Output Impedance 

75 Ohm 

Input/Output Level 

1.0 Vp-p typical 

Differential Gain 

< 1% typical 

Differential Phase 

< 1

o

 typical 

SNR 

>60dB 

DATA 

 

Channel / Connector 

3 / 7-pin Screw Terminal 

Direction 

Bi-directional (Duplex) 

Electrical Format 

RS232, RS422, RS485 (2-wire, 4-wire) 

Transmission Rate 

0~256 Kbps 

POWER 

 

Power consumption 

12VDC @ 8.4W 

Power Supply 

Standalone unit: FT/PA12V DC Adaptor 

Card module: Powered by FT-C18 chassis 

Connector (Micro unit) 

2-pin Screw Terminal 

PHYSICAL 

 

Weight 

Standalone unit: 0.9 kg          Card module: 0.4 kg 

Dimensions (W x H x D) 

Standalone unit: 156 x 50.5 x 223 mm (MAX)     

Card module: 148 x 41 x 213 mm (MAX) 

ENVIRONMENTAL 

 

Operating Temperature 

-40

o

C ~ +75

o

Storage Temperature 

-40

o

C ~ +85

o

Relative Humidity 

0 ~ 95% non-condensing 

MTBF 

>100’000 Hours 

*

If the optical connector is FC type, the suffix in the model number will be 

“-

F

XX

”. Eg. FTD110DBMicro-

F

ST

 

Содержание FTD110DB-SMR3

Страница 1: ...lation Operation Manual www ot systems com 1 Installation and Operation Manual FTD110DB XXR3 Series 8 bit Digital Series Triple Independent Video with Triple Bi directional Data Fiber Optic Receiver O...

Страница 2: ...110DB SSR3L Multi Mode Receiver FTD110DB SMR3 Compatible with the following TRANSMITTERS FTD110DBMicro Series FTD110DBM Series FTD110DB Series Single Mode FTD110DBMicro SST FTD110DBMicro SSTL Multi Mo...

Страница 3: ...INSTALLATION 7 3 1 GENERAL 7 3 2 STANDALONE UNIT INSTALLATION 7 3 3 CARD MODULE INSTALLATION 8 4 CABLE CONNECTIONS SETUP PROCEDURES 8 4 1 SYSTEM CABLE CONNECTIONS 8 4 2 DATA PORT ASSIGNMENT AND PIN C...

Страница 4: ...to Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up Caution Any access to the controls adjustments or performing op...

Страница 5: ...less of the type of communication protocol implemented within the system Time Division Multiplex TDM technology is employed for digital transmission of forward video and data whereas optical Wavelengt...

Страница 6: ...lone Unit Multi Mode FTD110DB SMR3SA Triple Independendent Multi mode Video Receiver Data Transceiver Standalone Unit Card Modules Single Mode FTD110DB SSR3 Triple Independendent Single mode Video Rec...

Страница 7: ...tal of 9 cards can be housed inside the chassis 3 2 Standalone unit installation a Mount the standalone unit onto a fixture either on the wall or on a flat surface with four screws through the holes o...

Страница 8: ...ce the chassis is powered up check that the red POWER LED on the front and back panels of the card modules are lit If not check the power supply cable connections between the chassis and the power sup...

Страница 9: ...10DB XXR3 Series Receiver Fig 4 1 Micro units to Card Module connection diagram FTD110DB XXR3SA Series Receiver Fig 4 2 Micro units to Standalone unit connection diagram TRANSMITTERS CAN BE FTD110DBMi...

Страница 10: ...Full Duplex Data communication connection diagram Transmitter End Receiver End User s Equipment DATA PORT 7 PIN DATA PORT 7 PIN User s Equipment TX 1 IN 1 IN TX TX 2 IN 2 IN TX RX 3 OUT 3 OUT RX RX 4...

Страница 11: ...OUT RX Sig COM 7 Sig COM 7 Sig COM Sig COM Fig 4 3 3 Connector Pin Assignments for RS232 data format at Data port 4 3 Dip switch setting procedures The only setup procedure is to select the appropriat...

Страница 12: ...he input and output lines terminated in the ONE Tx to ONE Rx configuration For RS485 2 4 wire communication the RS485 device can be disabled to stay in a Hi Z state It is very important that the data...

Страница 13: ...d Lit when power is supplied to the Receiver OL Yellow Lit when optical signal from transmitter to receiver is active V1 V2 or V3 Green Lit when video signals are available at the VIDEO OUT connectors...

Страница 14: ...ial Gain 1 typical Differential Phase 1 o typical SNR 60dB DATA Channel Connector 3 7 pin Screw Terminal Direction Bi directional Duplex Electrical Format RS232 RS422 RS485 2 wire 4 wire Transmission...

Страница 15: ...andalone unit mm 8 Warranty Information All OT Systems FT Series products are subject to a limited life time warranty offered by the company in normal circumstances Please refer to the OT Systems Prod...

Страница 16: ...sales ot systems com Technical Support techsupport ot systems com EMEA Operation Address J Slovackio str 4 LT 11107 Vilnius Lithuania Tel 370 60730087 Fax 370 52051855 Sales Inquiries sales ot systems...

Отзывы: