background image

FT120DB Series Installation & Operation Manual 

 

www.ot-systems.com

 

 

 

 

14 

 

(6)  Specifications 

MODELS* 

 

PARAMETERS

 

FT120DB-SST(R)SA 

FT120DB-SST(R) 

(Single-Mode)

 

FT120DB-SST(R)LSA 

FT120DB-SST(R)L 

(Single-Mode) 

FT120DB-SMT(R)SA 

FT120DB-SMT(R) 

(Multi-Mode)

 

OPTICAL 

 

 

 

No. of Fiber / Connector 

1 / ST (or FC) 

1 / ST (or FC) 

1 / ST (or FC) 

Wavelength 

1310/1550 nm 

1550/1310 nm 

1310/1550 nm 

Optical Power Budget 

17 dB 

24 dB 

23 dB 

Max Distance 

40 km 

60 km 

4 km 

ELECTRICAL VIDEO 

 

Channel / Connector 

1 / BNC 

System 

PAL, NTSC, SECAM 

Bandwidth 

6.5 MHz 

Input/Output Impedance 

75 Ohm 

Input/Output Level 

1.0 Vp-p typical 

Differential Gain 

< 1% typical 

Differential Phase 

< 1

o

 typical 

SNR 

>65dB 

DATA 

 

Channel / Connector 

2 / 7-pin Screw Terminal 

Direction 

Bi-directional (Duplex) 

Electrical Format 

RS232, RS422, RS485 (2-wire, 4-wire) Tri-state 

Transmission Rate 

0~256Kbps 

POWER 

 

Power consumption 

12VDC @ 5.4W 

Power Supply 

Standalone Unit: FT/PA12V DC Adaptor 

Card module: Powered by FT-C18 chassis 

Connector (Standalone unit) 

2-pin Screw Terminal 

PHYSICAL 

 

Weight 

Standalone unit: 0.76 kg          Card module: 0.3 kg 

Dimensions (W x H x D) 

Standalone unit: 156 x 50.5 x 223 mm (MAX) 

Card module: 148 x 41 x 213 mm (MAX) 

ENVIRONMENTAL 

 

Operating Temperature 

-40

o

C ~ +75

o

Storage Temperature 

-40

o

C ~ +85

o

Relative Humidity 

0 ~ 95% non-condensing 

MTBF 

>100’000 Hours 

*

If the optical connector is FC type, the suffix in the model number will be 

“-

F

XX

”. Eg. FT120DB-

F

ST 

Содержание FT120DB Series

Страница 1: ...Digital Fiber Optic Manufacturing Specialists Installation and Operation Manual FT120DB Series 10 bit Digital Series 1 ch Video with 2 Bi directional Data Fiber Optic Converter OT Systems Ltd 2009 Rev...

Страница 2: ...ivers FT120DB SSRSA FT120DB SSRLSA Multi Mode Transmitter FT120DB SMTSA Multi Mode Receiver FT120DB SMRSA Card Modules Single Mode Transmitters FT120DB SST FT120DB SSTL Single Mode Receivers FT120DB S...

Страница 3: ...tandalone unit installation 6 3 3 Card module installation 7 4 CABLE CONNECTIONS SETUP PROCEDURES 7 4 1 System cable connections 7 4 2 Data port assignment and pin connections 9 4 3 Dip switch setting...

Страница 4: ...I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up Caution Any access to the controls adjustments or performing operations...

Страница 5: ...l transmission of forward video and data whereas optical Wavelength Division Multiplex WDM technique is employed for simultaneous reverse data transmission so as bi directional data transmission is ac...

Страница 6: ...tter 2 Ch Data Transceiver Standalone Unit FT120DB SMRSA Multi mode 1 Ch Video Receiver 2 Ch Data Transceiver Standalone Unit Card Modules Single Mode FT120DB SST Single mode 1 Ch Video Transmitter 2...

Страница 7: ...otal of 9 cards can be housed inside the chassis 3 2 Standalone unit installation a Mount the standalone unit onto a fixture e g a plank either on the wall or on a flat surface with four screws pierci...

Страница 8: ...les whether they have been inserted properly d Connect all the signal inputs and outputs at the back of the unit with appropriate cables fiber optic cable for optical link BNC cable for video input ou...

Страница 9: ...tion Manual www ot systems com 8 Standalone Transmitter Card Module Receiver Fig 4 2 Standalone unit to Card Module connection diagram Card Module Transmitter Card Module Receiver Fig 4 3 Card Module...

Страница 10: ...N A IN OUT Sig COM 4 Wire RS422 485 Full Duplex Data communication connection diagram Transmitter End Receiver End User s Equipment DATA PORT 7 PIN DATA PORT 7 PIN User s Equipment TX 1 IN 1 IN TX TX...

Страница 11: ...6 OUT RX Sig COM 7 Sig COM 7 Sig COM Sig COM Fig 4 4 3 Connector Pin Assignments for RS232 data format at Data port 4 3 Dip switch setting procedures The only setup procedure is to select the appropr...

Страница 12: ...input and output lines terminated in the ONE Tx to ONE Rx configuration For RS485 2 4 wire communication the RS485 devices can be disabled to stay on Hi Z state It is very important that the data line...

Страница 13: ...y lightning and other power surges in addition to the incorporation of the surge protective devices into the products a screw is provided on the Standalone cabinets Fig 4 7 It is highly recommended th...

Страница 14: ...tical Connector for fiber cable connection VIDEO IN BNC Video Connector for video signal input DATA 7 pin Screw Terminal Blocks for data signals 5 2 FT120DB Series Receiver LED Indicators Indicator Co...

Страница 15: ...in 1 typical Differential Phase 1 o typical SNR 65dB DATA Channel Connector 2 7 pin Screw Terminal Direction Bi directional Duplex Electrical Format RS232 RS422 RS485 2 wire 4 wire Tri state Transmiss...

Страница 16: ...efer to the OT Systems Products Warranty Statement for details Access to the statement is available in our company website at www ot systems com 9 Contact Information OT Systems Ltd Hong Kong Unit 102...

Отзывы: