IMPORTANT:
• Parts and accessories are for use with this appliance
only. Parts, including the food container lid, are not to
be boiled or microwaved.
• Place the appliance on a flat and stable surface.
• Make sure the appliance and supply cord are out of
children’s reach.
1. Fill nutrient collector/measuring cup (17) to the
recommended water level (See table on page 13) and
pour it into the water reservoir (13).
WARNING: Do not overfill water reservoir. The bottle
or food container may be heated too long and the
food may be too hot for feeding.
2. Lock the water reservoir lid (14) into place on
the water reservoir (15) by twisting the double
arrow icon clockwise until the blend/warming
icon
is aligned with the arrow at the base.
• Make sure the steam guide (15) is facing the warming
icon and is aligned with the steam icon
3. Lock the warmer (24) into place over the motor drive
(16) by twisting the arrow on the warmer (24) from
unlocked to locked . The warmer assembly is
now locked into position for Warming.
• Make sure the warmer steam entry (25) is fully
engaged with the water reservoir lid steam guide (16).
4. Place the bottle or food container in the center of the
warmer (24).
• Place food container lid (29) on container to pre-
vent food spills during warming.
5. Plug the power supply cord into an electrical outlet
and press the on / off button (10).
• A 1-second beep and illuminated power light will
indicate the Oster
TM
Baby Nutricenter is on.
6. Press the steam button (12).
• A 1-second beep and illuminated steam light will
indicate that WARMING has begun.
WARNING: During WARMING, the warmer
releases steam through the interior vent holes in
the warmer holder. Keep clear of the steam during
Warming to avoid injury.
• WARMING is complete when a 3 second beep is
sounded and the steam light turns off. The Oster
TM
Baby Nutricenter System is now in stand-by mode
and the heating element is off.
7. Press on/off button (10).
• The power light turns off, indicating that the
Oster
TM
Baby Nutricenter is off.
8. Remove the bottle or food container for feeding.
WARNING: Bottle and food container are hot after
warming.
WARNING: Allow sufficient time for the bottle or
food container to cool before handling or use oven
mitts to handle immediately.
• Shake bottle or mix food thoroughly to ensure even
temperature.
• Test the temperature of the food before feeding.
If food is not warm, then operate for another
WARMING cycle.
IMPORTANT:
• Bottles, accessories, toys and other objects should
be cleaned before sterilizing.
• This sterilizer does not sterilize up to clinical
standards.
• Place the appliance on a flat and stable surface.
• Make sure the appliance and supply cord are out
of children’s reach.
• Ensure drain plug is secured to prevent leaking
during sterilizing.
1. Fill the water reservoir (13) to water level 3.
2. Lock the water reservoir lid (14) into place on the
water reservoir (13) by twisting the double arrow
icon counterclockwise until the sterilizer icon
is aligned with the arrow at the base.
3. Place the bottle tray (20) into the sterilizer base
(21).
• Place cleaned baby bottles upside down onto
the bottle tray (20).
4. Place the accessory tray (19) over the bottles,
onto the top interior edge of the sterilizer base
(20).
• Place accessories disassembled on top of the
accessory tray (19).
5. Cover with the sterilizer lid (18), slide sterilizer
towards the Oster
TM
Baby Nutricenter base until
the sterilizer steam entry (23) engages with the
water reservoir steam guide (15).
6. Plug the power supply cord into an electrical
outlet and press the on/off button (10).
• A 1-second beep and power light will indicate
the Oster
TM
Baby Nutricenter is on.
7. Press the steam button (11).
• A 1-second beep and illuminated steam light
will indicate STERILIZING has begun. Sterilizing
can be stopped at any time by pressing the
steam button (11).
WARNING:
During Steaming, the sterilizer
releases steam through the steam vent holes on
the top of the sterilizer lid. To avoid injury, keep
clear of the steam.
8. STERILIZING is complete when a 3 second beep
is sounded and the steam light turns off. The Os-
ter
TM
Baby Nutricenter System appliance is now
in stand-by mode and the heating element is off.
9. Press the on/off button (10).
• The power light turns off, indicating that the
Oster
TM
Baby Nutricenter System is off.
10. Remove sterilized bottles and accessories as re-
quired for feeding.
WARNING
: Parts are hot after
sterilizing. Allow sufficient time for the sterilizer
lid, bottles and accessories to cool before han-
dling or use oven mitts to handle immediately.
11. Remove the drain plug (22) located on the bot-
tom of the sterilizer base (21) to release excess
condensation after sterilizing.
WARNING
:
Sterilized water is hot. Allow water to cool before
draining.