3.0

CONFIGURATION

3.1

DC Powered Chassis Site Preparation

Power source should be available within 5 ft. of the chassis. The over
current protection for connection with centralized DC shall be provided in
the building installation, and shall be a UL listed circuit breaker rated
20Amps, and installed per the National Electrical Code, ANSI/NFPA-70.

This equipment requires 18-60VDC/1.0Amp rated power. Appropriate
overloading protection should be provided on the DC power source outlets
utilized.

WARNING:

Only a DC power source that complies with

safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.

WARNING REGARDING EARTHING GROUND:

o

o

o

o

This equipment shall be connected to the DC supply

system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the
DC supply system earthing electrode is connected.

This equipment shall be located in the same immediate

area (such as adjacent cabinets) as any other equipment
that has a connection between the earthed conductor of
the same DC supply circuit and the earthing conductor,
and also the point of earthing of the DC system. The DC
system shall not be earthed elsewhere.

The DC supply source is to be located within the same

premises as this equipment.

There shall be no switching or disconnecting devices in

the earthed circuit conductor between the DC source and
the earthing electrode conductor.

The operating temperature of this equipment is 0 to 50 degrees C. If installed
in a closed or multi-module rack assembly, the operating ambient
temperature of the rack must not exceed the maximum rated 50 degrees C.

Installation of the equipment should be such that the air flow in the front
and back of the chassis is not compromised or restricted.

Never use this equipment to carry any weight except its own. Never use it
as a shelf to support weight of other equipment.

3.2

DC Powered Chassis Mounting

Locate the DC circuit breaker, and switch the circuit breaker to the OFF

position.

Page 5

Содержание 6750-FK

Страница 1: ...FlexSwitchTM 1Fx 4U Model 6750 FK Replacement Kit User Manual 140 Technology 500 Irvine CA 92618 Phone 949 250 6510 Fax 949 250 6514...

Страница 2: ...Installation 4 3 0 CONFIGURATION 5 3 1 DC Powered Chassis Site Preparation 5 3 2 DC Powered Chassis Mounting 5 3 3 Configuring the DIP switches 7 3 3 1 4Tx Switch Module 7 3 3 2 Media Converter Module...

Страница 3: ...that enables easy attachment to hubs switches and workstations The 100BASE FX fiber port supports half or full duplex operation The 6750 FK features on board and front panel accessible DIP switches fo...

Страница 4: ...r 2 Module chassis with the backplanes enabled on both modules and Link Segment selected see Section 6 0 If the modules are removed carefully slide the module into the open slot Align the module with...

Страница 5: ...e located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and a...

Страница 6: ...s used in making the positive negative and ground connections Use the same color assignment for the connection at the circuit breaker Connect the power wires to the circuit breaker and switch the circ...

Страница 7: ...Backplane Port B Enable Disable BP B EN DIP switch This DIP switch must be in the LEFT position factory default for the module to operate correctly The switch provides backplane connectivity with the...

Страница 8: ...Full Duplex DIP switch to match duplex mode the connecting UTP device When the UTP AN MAN DIP switch is in the auto negotiate AN position and the UTP Full Half Duplex DIP switch is in the Full Duplex...

Страница 9: ...vice and check for link status Note Attaching an auto negotiating UTP port of the 6750 FK to a device with a manual forced hard coded UTP port may result in an unpredictable port setting with excessiv...

Страница 10: ...he Link Propagate Link Segment LP and the Remote Fault Detect RFD DIP switches are in the DOWN position factory default Link Segment mode is enabled When the Link Propagate Link Segment LP DIP switch...

Страница 11: ...ity Port 2 100 Link Green Not Linked at 100Mbps On Port Linked at 100Mbps Blinking Data Activity Port 2 10 Link Green Not Linked at 10Mbps On Port Linked at 10Mbps Blinking Data Activity Port 3 100 Li...

Страница 12: ...as power Fiber FDX Green Fiber in Half Duplex On Fiber in Full Duplex Fiber Lk Act Green No Fiber Link On Fiber Link is Active Blinking Data Activity UTP AN Green UTP is in Manual Negotiation On UTP i...

Страница 13: ...timode 50 125 62 5 125 100 140um Singlemode 9 125um UTP Connector Type RJ45 Fiber Connector Type Dual Fiber ST SC DIP Switches Fiber FDX HDX UTP AN MAN 10 100 FDX HDX Link Modes LS LP RFD Power Requir...

Страница 14: ...nk signal will continue to propagate through to the next port in the network A loss of link on the UTP port will cause the fault to propagated forward causing the fiber and UTP ports at the remote end...

Страница 15: ...anty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense...

Страница 16: ...ct contact Omnitron Technical Support Phone 800 675 8410 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology Dr 500 Irvine CA 92618 Email support omnitron systems com...

Отзывы: