One Stop Systems
OSS-PCIe-HIB38x8-QUAD | 31
4
Verify Hardware
An operational Target and Host cards will have the following LEDs illuminated.
4.1
Target card LEDs
1.
Bracket LINK LED: Solid green – Gen 3 or Blinking green – Gen 2 (Blinking frequency: 2Hz ). Gen1 (Blinking frequency: 1Hz)
2.
Board LEDs :
PWRGD – Solid green
CE LINKED – Solid green or blinking green, depending on the blink rate.
o
Gen3- solid green
o
Gen2 - Blinking frequency: 2Hz
o
Gen1 - Blinking frequency: 1Hz
o
NOTE: 1 Hz means it blinks one time per second. Therefore, .25 would be once every 4 seconds and 2Hz would be twice a second.
4.2
Host card LEDs
If you have four expansion units that are attached, all four LINK LEDs (located on the bracket) will be illuminated.
1.
Bracket LED : Solid green – Gen 3 or Blinking green – Gen 2 (Blinking frequency: 2Hz ). Gen1 (Blinking frequency: 1Hz)
3.
Board LEDs :
PWRGD – Solid green
CE LINKED – Solid green or blinking green, depending on the blink rate.
o
Gen3- solid green
o
Gen2 - Blinking frequency: 2Hz
o
Gen1 - Blinking frequency: 1Hz