Mounting Guide
7/20 V1
3 of 6
ProPoint
™
Pixel
Mounting Guide
1a
Orientation and Mounting – All Models
Line Voltage Wiring
2
Mounting Details
1b
UP
UP
To
Luminaire
To
Junction Box
For applications where
luminaire is mounted with
cables exiting horizontally,
install a drip loop suitable
for shedding water ahead
of cable glands.
ALLOWABLE MOUNTING
ORIENTATION
Power and data cables exit
luminaire downward allowing
water to travel away from
cable gland gaskets.
PROHIBITED MOUNTING
ORIENTATION
Power and data cables
exit luminaire upward
allowing water to travel
into cable gland gaskets.
Preparation
Remove the ProPoint Pixel luminaire from the packaging and place the unit on a level
surface.
Inspect the luminaire and cables for any damage as a result of shipping.
Mounting
CAUTION:
It is the installer’s responsibility to make sure that the mounting surface can
handle the static weight of the fixtur
e as well as dynamic loading from environmental
factors such as wind and snow/ice buildup. The use of Grade 5 or higher hardware (by
others) is recommended.
Make sure that the bolts on the mounting surface align with the holes on the surface
mount bracket.
Install the luminaire to the mounting surface and secure using appropriate hardware
(by others).
NOTICE:
The ProPoint Luminaire should be installed with the power and data
cables exiting the housing directly down when the luminaire is mounted on a vertical
surface. For applications that require horizontal orientation of the power and data
cables, the installer shall apply RTV sealant to the cable gland entry points. The
luminaire shall not be installed with the power and data cabling oriented up.
WARNING:
Risk of electrical shock. Make sure that the branch circuit is disconnected
prior to installation or inspection.
CAUTION:
Make sure that the cable is protected from cuts and abrasions that may
result in damage to the outer jacket.
CAUTION:
IP failure induced by stressed/damaged cable entry points during or after
installation will void the product warranty.
NOTICE:
A voltage divider is recommended (and may be required by local electrical code)
when a single junction box is utilized for termination of the power supply and data cables.
NOTICE:
Cable bend radius must NOT be less than the Minimum Bending Radius
(4X Cable Diameter) as specified by cable manufactur
er and the Non-Bendable
Length of 5cm (2in) near the cable gland MUST be adhered to. In addition to the
Minimum Bending Radius, ensure that 5cm (2in) of cable at the connector junction
is kept straight (see image below).
Minimum Bending Radius
ProPoint Pixel Power Requirements:
Input Voltage: . . . . . . . . . . . 120-277V
ac
Auto Switching, Single Phase
Input Frequency: . . . . . . . . . . . . . . . . . . . . . . 50-60Hz
Power Consumption: . . . . . . . . . . . . . . . . . . . . . . . 20W
Power Factor: . . . . . . . . . . . . . . . . . . . . . . . . . .
≥
0.9
Luminaire Wire Color – UL/CE. . . . . . . . . . . Branch Circuit Termination
Brown
. . . . . . . . . . . . . .Line or Live Conductor
Blue
. . . . . . . . . . . . . . . Neutral Conductor
Yellow/Green
. . . . . . . . . . . . . Earth Ground Conductor
www.traxontechnologies.com
www.osram.us/traxon
©2020 TRAXON TECHNOLOGIES – AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON
™
AND TX CONNECT
®
ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U.
PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.