Mounting Guide

7/20 V1

3 of 6

ProPoint

 Pixel

Mounting Guide

1a

Orientation and Mounting – All Models

Line Voltage Wiring

2

Mounting Details

1b

UP

UP

To

Luminaire

To

Junction Box

For applications where 
luminaire is mounted with 
cables exiting horizontally, 
install a drip loop suitable 
for shedding water ahead 
of cable glands. 

ALLOWABLE MOUNTING 
ORIENTATION
Power and data cables exit 
luminaire downward allowing 
water to travel away from 
cable gland gaskets.

PROHIBITED MOUNTING 
ORIENTATION
Power and data cables 
exit luminaire upward 
allowing water to travel 
into cable gland gaskets.

Preparation

Remove the ProPoint Pixel luminaire from the packaging and place the unit on a level 
surface.
Inspect the luminaire and cables for any damage as a result of shipping.

Mounting

CAUTION:

 It is the installer’s responsibility to make sure that the mounting surface can 

handle the static weight of the fixtur

e as well as dynamic loading from environmental 

factors such as wind and snow/ice buildup. The use of Grade 5 or higher hardware (by 
others) is recommended.
Make sure that the bolts on the mounting surface align with the holes on the surface 
mount bracket.
Install the luminaire to the mounting surface and secure using appropriate hardware  
(by others).

NOTICE:

 The ProPoint Luminaire should be installed with the power and data 

cables exiting the housing directly down when the luminaire is mounted on a vertical 
surface. For applications that require horizontal orientation of the power and data 
cables, the installer shall apply RTV sealant to the cable gland entry points. The 
luminaire shall not be installed with the power and data cabling oriented up.

WARNING:

 Risk of electrical shock. Make sure that the branch circuit is disconnected 

prior to installation or inspection.

CAUTION:

 Make sure that the cable is protected from cuts and abrasions that may 

result in damage to the outer jacket.

CAUTION:

 IP failure induced by stressed/damaged cable entry points during or after 

installation will void the product warranty.

NOTICE:

 A voltage divider is recommended (and may be required by local electrical code) 

when a single junction box is utilized for termination of the power supply and data cables.

NOTICE:

 Cable bend radius must NOT be less than the Minimum Bending Radius 

(4X Cable Diameter) as specified by cable manufactur

er and the Non-Bendable 

Length of 5cm (2in) near the cable gland MUST be adhered to. In addition to the 
Minimum Bending Radius, ensure that 5cm (2in) of cable at the connector junction 
is kept straight (see image below).

Minimum Bending Radius

ProPoint Pixel Power Requirements:

Input Voltage:  .   .   .   .   .   .   .   .   .   .   .  120-277V

ac

 Auto Switching, Single Phase

Input Frequency:     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  50-60Hz
Power Consumption:  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 20W
Power Factor: .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .

0.9

Luminaire Wire Color – UL/CE.   .   .   .   .   .   .   .   .   .   .   Branch Circuit Termination
Brown   

  .   .   .   .   .   .   .   .   .   .   .   .   .   .Line or Live Conductor

Blue    

  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   Neutral Conductor

Yellow/Green    

  .   .   .   .   .   .   .   .   .   .   .   .   . Earth Ground Conductor

www.traxontechnologies.com
www.osram.us/traxon

©2020 TRAXON TECHNOLOGIES – AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON

 AND TX CONNECT

®

 ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. 

PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.