Osram LS/PD MULTI 3 Скачать руководство пользователя страница 2

Fitting (cont.)

Selecting the installation location

H  Surveillance cone: entire workplace; not on window surfaces
I  Avoid exposure to direct light
K  Avoid drafts (e.g. from ventilators or fans)
L  Installation distance = min. installation height

Appendix

Technical data

Combined control and 

supply connection

4-pin modular connection (4p4c)
1: Supply voltage 

2: Light measurement value

 

3: Motion signal 

4: Signal ground

Length 2.1 m

Maximum total length 

of signal line (incl. all 

connections to the 

control units)

See control unit

Insulation

Basic insulation as per IEC 664

Dimensions  

(L x W x H)

55 x 21 x 24.5 mm

Light sensor detection 

area

20 - 600 lx (measured at sensor), 

 

opening angle approx. 90°

Motion detection area

Conical, opening angle approx. 80°

Installation height

2 - 4 m

80°

80°

H

I

K

L

> h

h

21mm

24,5 mm

5 mm

20 mm

45mm

15 mm

21 mm

35 mm

55 mm

The CE requirements to EN 60928 are fulfilled. 

 

The EMC requirements to EN 61547 are fulfilled.

Conformity with the relevant EU directives is 

confirmed by the CE symbol. 

Отзывы: