AXCOR PROFILE 600 TEATRO

329

(12.95")

388

(15.28")

636

(25.04")

570

(22.44")

785

(30.91")

409

(16.10")

607

(23.90")

POWER SUPPLIES
AC power input 100-240V, 50/60 Hz.

INPUT POWER
800 VA @230Vac - 50Hz.

LIGHT SOURCE
500W White LED engine.
Versions available:
- CRI: at least 70, CT 6500K (Axcor Profile 600

Teatro)

- CRI: at least 90, CT 5600K (Axcor Profile 600

HC Teatro)

OPTICS
Ø 132mm front lens / 5.3°- 47.2° linear Zoom

CHANNELS
40/44 control channels.

EFFECTS SECTION
- Motorized framing system with 4 focal planes
- Smooth, flexible blade movements at variable speed
- 4 Blades that move separately.
- A "total curtain" effect made separately by each

of the 4 blades, in many 

- shapes and colors. / Small and large dynamic profiles.
- 90° rotation of the entire system, at variable speed.
- Rotating Gobos: 7 HD interchangeable gobos, ø

25.9;  image  ø  20;  indexable  on  540°:  plumens,
water lines, multiple cones, shattered, small dots,
broken circle, half circle.

- Animation  Wheel  (interchangeable  with  static

gobo  disk)  clockwise  and  counter-clockwise
rotation at variable speed.

- Rotating Prism: 1 x 4-facet prism, interchangeable,

indexable  on  540°;  clockwise  and  counter-
clockwise rotation at variable speed.

- Variable “soft edge” frost 0-100% linear.
- Iris with multiple macros (random, pulsing…)
- CMY and Linear CTO.
- Color  wheel  5  colors:  Dark  Red,  Green.  CRI,

Gold amber, Navy blue.

- Pan/Tilt Resolution 16 bit.
- Focus Resolution 16 bit.
- Gobo Resolution 16 bit.
- Dimmer Resolution 16 bit, 4 dimmer curves.
- Electronic strobe @25 f/sec.
- Movement control vectorial.

ELECTRONICS
- Control signal USITT DMX 512.
- Long life self-charging battery.
- Display Graphic LCD backlit b/w Display.
- Function reset via on-board menu.
- Function reset from the lighting desk.
- “AUTOTEST” function from menu.
- Electronic  monitoring  with  status  error  reporting

and logging.

- Cooling system monitoring.
- DMX level monitoring on all channels.
- Internal data transmission diagnostics.
- Upgrade with no power (CPU only) firmware
- Firmware upload from another fixture (CPU only).
- Firmware Upgrade via Web Server.
- Protocols/Functions: RDM, Web Server, ArtNet.
- Extremely reliable communication RS485 bus.

IP RATING
IP 20 
- Protected against the entry of solid bodies
larger than 12mm (0.47”); 
No protection against the entry of liquids.

INPUTS
DMX 512, 3 and 5 pin In & Out connector.
Ethernet.
Neutrik PowerCon True1 (IN & OUT).

MOTORS
Stepper motors, microprocessor controlled.

MOVING BODY
- PAN range 540°
- TILT range 268°.

BODY
- Aluminum and steel structure with plastic covers.
- Two side handles for transportation.
- Device  locking  PAN  and  TILT  mechanisms  for

transportation and maintenance.

WORKING POSITION
- Working in any position.
- Hanging  system:  with  fast-lock  omega  clamps

(1/4 turn – pn183102/805) on the base.

- Optional safety chain.

SAFETY SPECIFICATIONS
- Minimum  distance  of  illuminated  objects  3

meters (9’ 10”).

- Minimum distance from flammable materials 0.2

meters (8”).

- Max ambient temperature 40°C (104°F).
- Max  temperature  of  the  external  surface  90°C

(194°F).

- Safety  devices  circuit  breaker  with  thermal

protection.

- Thermally  protected  power  supply  (overheating

and cooling failure)..

- Forced ventilation with axial fans.

NOISE LEVEL
- 42.5  dBA  standard  mode  Led  power  500W

(background 32.0)

- 38.5  dbA  silent  mode  LED  Power  400W

(background 32.0)

- 35.0  dBA  silent  mode  Led  Power  300W

(background 32.0)

CE MARKING
In conformity with the European Directives:
- 2014/35/EU  -  Safety  of  electrical  equipment

supplied at low voltage (LVD).

- 2014/30/EU - Electromagnetic Compatibility (EMC).
- 2011/65/EU  -  Restriction  of  the  use  of  certain

hazardous substances (RoHS).

- 2009/125/EC  -  EcoDesign  requirements  for

Energy-related Products (ErP).

ETL
This product is available, on demand, with cETLus
Listed Mark.

PACKAGING
- Carton box + Polystyrene
- Carton box + Foam shell
- Flight case + Foam shell (2 position)

WEIGHT
33 Kg (72.7 lbs).

ACCESSORIES
- Safety chain 105041/003
- Optional static gobo C61785
- Foam shell F21310/001
- Flight case F21311 (2 foam included)

5.  SPECIFICATIONS

Содержание CL3016

Страница 1: ...e Contents 2 1 Safety information 3 2 Unpacking and preparation 4 3 Installation and start up 4 3 1 Installing the fixture 4 3 2 Connecting to manis supply 5 3 3 Connecting the control signal line DMX...

Страница 2: ...nformationen bez glich dieses Produkts genau zu lesen und aufzubewahren Sie sind in Digitalversion immer unter folgendem Link auffindbar www claypaky com Ref FIS00W Safety Information Axcor 600 series...

Страница 3: ...RO 1 PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 Packing contents Fig 1 90 9 0 9 0 9 0 UNLOCKED LOCKED 4 5 4 5 45 4 5 45 4 5 4 5 2 x 183102 805 2 UNPAC...

Страница 4: ...on special rubber feet on a truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 105041 001 available on req...

Страница 5: ...an when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled 1 2 Dmx Address Warning Message Fixture ID 8 Connecting to the control sig...

Страница 6: ...entarily activate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F...

Страница 7: ...Pan and Tilt movements Refer to the instructions in the UNPACKING AND PREPARATION section Opening the head covers Fig 10 Closing the head covers Fig 11 1 4 Turn 2 1 CLICK 1 4 Turn 2 1 4 Turn 1 2 1 10...

Страница 8: ...dirt from the reflectors from the lenses and filters It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following...

Страница 9: ...ion of the effect modules Preliminary operations Fig 13 NOTE Do not disconnect wiring harnesses when the fixtures is switched on to avoid to damage electronic boards Do not switch on the fixtures with...

Страница 10: ...ide 1 3 3 2 14 Extraction of the effect modules Preliminary operations Fig 14 NOTE Do not disconnect wiring harnesses when the fixtures is switched on to avoid to damage electronic boards Do not switc...

Страница 11: ...tion of the effect modules Fig 15 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in...

Страница 12: ...traction of the effect modules Fig 16 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicate...

Страница 13: ...tion of the effect modules Fig 17 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in...

Страница 14: ...14 AXCOR PROFILE 600 TEATRO Cleaning of the filters Fig 18 2 1 1 4 Turn 3 4 18 4 4 Cleaning of the filters...

Страница 15: ...15 AXCOR PROFILE 600 TEATRO 1 1 4 Turn 4 5 2 5 4 3 3 19 Cleaning of the filters Fig 19 Continue...

Страница 16: ...012 GOD019 011 25 0 1 1 0 1 25 9 0 1 Immagine 20 21 Replacing rotating gobos max 20 mm image thickness 1 mm Fig 21 The rotating gobo wheel only use dichroic glass gobos it is not possible to use metal...

Страница 17: ...PO 2 To determine which side of a godo is coated hold an odject up to it On the uncoated side there is a space between the object and its reflection Grey Black side away from light source Coated side...

Страница 18: ...OFILE 600 TEATRO This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 1 3 5 2 4 6 23 4 6 Batt...

Страница 19: ...ta transmission diagnostics Upgrade with no power CPU only firmware Firmware upload from another fixture CPU only Firmware Upgrade via Web Server Protocols Functions RDM Web Server ArtNet Extremely re...

Страница 20: ...IST025 001 EN Rev 0 06 2020 CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 www claypaky com...

Отзывы: