11

DMX Address

To select the 

DMX Address

, press the 

ENTER

button to show 

DMX ADDRESS

on the display. Use the 

DOWN

/

UP

button to adjust the address from 

1

to 

512

. Once the address has been selected, press the

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button

again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Setup

To select 

Setup

press the 

ENTER

button to confirm, use the 

UP

/

DOWN

button to select

DMX Modes, Dimmer Settings, Output Modes, Data Input,

Ethernet Interface, 

Display Setting or Frequency

.

DMX Modes 

To select the 

DMX Modes

, press the 

ENTER

button to show 

DMX Modes

on the display. Use the 

DOWN

/

UP

button to select the 

Mode1, Mode2,

Mode3, Mode4

or

Mode5

. Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press

the 

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Dimmer Settings 

To select the 

Dimmer Settings

, press the 

ENTER

button to show 

Dimmer Settings

on the display. Use the 

DOWN

/

UP

button to select the 

Dimmer

Curve

or

Dimmer Speed

. Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press

the 

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Dimmer Curve 

To select the 

Dimmer Curve

, press the 

ENTER

button to show 

Dimmer Curve

on the display. Use the 

DOWN

/

UP

button to select the 

Quadratic,

Linear, Inv.square

or

S Curve

. Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes

press the 

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

DIMMER CURVES 

Curve 1 - Linear: 

The increase in light intensity appears to be linear as DMX value is increased.

Curve 2 - Quadratic:

Light intensity control is finer at low levels and coarser at high levels.

Curve 3 - Inverse Square: 

Light intensity control is coarser at low levels and finger at high levels.

Curve 4 - (S-curve): 

Light intensity control is finger at low levels and high levels and coarser at medium levels.

Dimmer Speed 

To select the 

Dimmer Speed

, press the 

ENTER

button to show 

Dimmer Speed

on the display. Use the 

DOWN

/

UP

button to select the 

Fast

or

Smooth

.

Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again.

Hold and press the 

MENU

button for one second or wait for one

Output Modes 

To select the 

Output Modes

, press the 

ENTER

button to show 

Output Modes

on the display. Use the 

DOWN

/

UP

button to select the 

Boost, Regulated,

Silent

or

Ultra Silent

. Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Data Input 

To select the 

Data Input

, press the 

ENTER

button to show 

Data Input

on the display. Use the 

DOWN

/

UP

button to select the 

Auto, DMX

or

Art-Net

.

Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again.

Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Ethernet interface 

To select the 

Ethernet Interface

, press the 

ENTER

button to show 

Ethernet Interface

on the display. Use the 

DOWN

/

UP

button to select the 

Network,

Art-net 

or

Repeat on DMX

. Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes

press the 

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Linear

Quadratic

Inverse Square

S-curve

Содержание ADB Stagelight LEXPERT PROFILE L

Страница 1: ...ons on choosing a ADB product We thank you for your custom Please note that this product as all the others in the rich ADB range has been designed and made with total quality to ensure excellent perfo...

Страница 2: ...CTION 2 TECHNICAL SPECIFICATIONS 3 THE UNIT CONSTRUCTION 4 INSTALLATION 5 POWER 6 CONTROL PANEL 7 MAIN FUNCTION 8 HOW TO CONTROL THE UNIT 8 1 DMX Address Setting 8 2 DMX Configuration 8 3 DMX Connecti...

Страница 3: ...achige Version des Handbuchs mit Sicherheitshinweisen f r dieses ADB Produkt unter folgendem Link herunterladen www adbstagelight com Rif FIS00X Safety Information LEXPERT PROFILE L C mo obtener tu IN...

Страница 4: ...me type spare parts DO NOT touch any wire during operation as high voltage might be causing electric shock To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or m...

Страница 5: ...s DMX 512 ArtNET RDM Web page Master Slave and local Zoom Options 15 30 25 50 0 100 linear dimming Variable Strobe Effects Input Voltage AC 100 240V 50 60Hz Power Consumption 345W 230V AC Light Source...

Страница 6: ...ngles signs T 3 4 INSTALLATION 2 5 1 3 4 2 1 Lens Module 2 Clip for Gel Holder 3 Bracket 4 Main Body 5 Godo Slot Loosen two screws on two sides of Main Body MB rotate the zoom as the arrow and align i...

Страница 7: ...a power cable 14 AWG brown and blue cables installed ready for connection Power cord colors Fig 5 Lock out power to the installation Connect the conductors in the power cable to the distribution circ...

Страница 8: ...he next unit and output DMX signal 7 ETHERNET Transfers fixture s information to a main controller 8 Fuse T 6 3A To protect the unit from damage of over current 9 MAINS IN OUT PowerCon connection from...

Страница 9: ...on and the display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any changes pre...

Страница 10: ...LEXPERT PROFILE L 10...

Страница 11: ...MER CURVES Curve 1 Linear The increase in light intensity appears to be linear as DMX value is increased Curve 2 Quadratic Light intensity control is finer at low levels and coarser at high levels Cur...

Страница 12: ...e second or wait for one minute to exit the menu mode Contrast To select the Contrast press the ENTER button to show Inverted on the display Use the DOWN UP button to adjust Contrast from 1 to 30 Once...

Страница 13: ...again Hold and press the MENU button for one second or wait for one minute to exit the menu mode Device ID To select the Device ID press the ENTER button to show Device ID on the display and the displ...

Страница 14: ...You can operate the unit in five ways 1 Universal DMX controller 2 RDM 3 Master Slave 4 Art Net 5 Manual 8 1 DMX Address Setting If you use a universal DMX controller to control the units you have to...

Страница 15: ...0 108 109 110 111 159 160 161 162 207 208 209 210 253 254 255 Open Strobe variable speed Open Pulse Slow closing fast opening variable speed Open Pulse fast closing slow opening variable speed Open Ra...

Страница 16: ...Fine 0 100 3 Strobe 000 009 010 057 058 059 060 108 109 110 111 159 160 161 162 207 208 209 210 253 254 255 Open Strobe variable speed Open Pulse Slow closing fast opening variable speed Open Pulse fa...

Страница 17: ...ening variable speed Open Pulse fast closing slow opening variable speed Open Random Strobe Slow to Fast Open Random Pulse Slow to Fast Open 4 Control 000 009 010 045 046 080 081 115 116 150 151 235 2...

Страница 18: ...or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when...

Страница 19: ...e to DMX circuits C Some units don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the...

Страница 20: ...EN PRELIMINARY 10 2018 Clay Paky S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 39 035 301876 www claypaky it...

Отзывы: