8176-L 

 
 
 

Contrast Monitoring Display: Select 

Power Down

 from the main menu. 

 
 

Contrast Monitoring System FCC Information  

Smart Monitor FCC ID: BCG A1538 
Contrast Monitoring Display contains FCC ID: Z64-WL18SBMOD 
 
Smart Syringe FCC ID: 2AHUPSS 
Pressure Module FCC ID: 2AHUPPM 
 
Classifications per IEC 60601-1 / UL 60601-1: 
 

Degree of Protection: 

Type CF-Applied Part 

 

Mode of Operation: 

Noncontinuous 

 
Contrast Monitoring Display 
Enclosure Degree of Ingress Protection: 

IP31 

 
This device complies with part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that 
may cause undesired operation.

 

 

WARNING

: Changes or modifications to the Monitor, Smart Syringe or Pressure 

Module not expressly approved by Osprey Medical could void the user’s authority 
to operate the equipment.

 

ELECTROMAGNETIC INTERFERENCE PRECAUTIONS 

This equipment has been tested and found to comply with the limits for a Group 
1 Class B device, pursuant to IEC/EN 60601-1-2, 4

th

 edition. These limits are 

designed to provide reasonable protection against harmful interference. This 
equipment, if not installed and used in accordance with the instructions, may 
cause harmful interference to other equipment. However, there is no guarantee 
that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to other devices, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 

 

Reorient or relocate the other equipment. 

 

Increase the separation between the Monitor and the other equipment. 

 

Connect the other equipment into an outlet on a circuit different from that to 
which display is connected. 

 

Consult Osprey Medical for help. 

 

WARNING

: Portable and mobile RF communications equipment may affect the 

devices. The Monitor should not be used adjacent to or stacked with other 
equipment. If adjacent or stacked use is necessary, the Display should be 
observed to verify normal operation.

 

 

WARNING

: Use of accessories, transducers and cables other than those 

specified or provided by Osprey Medical could result in increased 
electromagnetic emissions or decreased electromagnetic immunity of this 
equipment and result in improper operation. 
 

WARNING

: Portable RF communications equipment (including peripherals such 

as antenna cables and external antennas) should be used no closer than 30 cm 
(12 inches) to any part of the Monitor or disposables, including cables specified 
by the manufacturer. Otherwise, degradation of the performance of this 
equipment could result. 
 
 
If performance of the system is lost or degraded due to electromagnetic 
interference, the procedure may continue without contrast monitoring. 
 
The Monitor and disposables have Bluetooth transceivers using short-
wavelength UHF radio waves in the ISM band from 2.4 to 2.485 GHz. The 
Pressure Module and Smart Syringe transmit a maximum signal strength of 
0.063 mW (-12 dBm ERP) using GSFM modulation as per IEEE 802.15.1 
Bluetooth standard and the Bluetooth SIG Working Group specification Version 
4.0+. 
 

WARNING

: Refer to the Smart Monitor or Contrast Monitoring Display 

Instructions for Use for the electromagnetic compliance information of this 
system. 
 
 

DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY 

THERE IS NO WARRANTY EXPRESSED OR IMPLIED, INCLUDING 
WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY 
OR OF FITNESS FOR A PARTICULAR PURPOSE, ON THE OSPREY 

MEDICAL PRODUCT(S) DESCRIBED IN THIS PUBLICATION. IN THE 
EVENT OF ANY DEFECT OR NONCONFORMITY OF OR TO THIS 
PRODUCT(S), OSPREY MEDICAL’S LIABILITY SHALL NOT BE IN EXCESS 
OF THE PURCHASE PRICE OF THE PRODUCT(S) TO BUYER. UNDER NO 
CIRCUMSTANCES SHALL OSPREY MEDICAL BE LIABLE FOR ANY 
DIRECT, INDIRECT OR CONSEQUENTIAL DAMAGES BASED UPON 
BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, 
STRICT TORT OR ANY OTHER THEORY ARISING OUT OF THE 
PURCHASE, USE OR REUSE OF THIS PRODUCT(S). OSPREY MEDICAL 
NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR 
IT ANY OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY IN 
CONNECTION WITH OSPREY MEDICAL PRODUCT(S). Descriptions or 
specifications in Osprey Medical printed matter, including this publication, are 
meant solely to generally describe the product at the time of manufacture and 
do not constitute any express warranties.  

 

 

Packaging Symbol Definitions 

 

Expiration Date 
YYYY-MM-DD. 
Use by last day 
of month (MM).

 

 

 

Manufacturer 

 

 
 

STERILE 

│EO

 

 

Sterilized by 
ethylene oxide 

 

  

Consult 
electronic 
Instructions for 
Use 
  

 
 
 
 

Keep Dry

 

 

REF

 

Model number 

 

Single Use 

 

 

European 
Conformity

 

 

LOT  

 

Lot Number

 

RxOnly 

Prescription 
Only 

 

 

 

Do Not Use if 
Package is 
Damaged 

 

EN IEC 60601-1 
applied part Type 
CF Defibrillation-
proof 

 

MR Unsafe

 

 

 

 

 

 

EU authorized 
representative 

 

Australian Communications and Media Authority mark 

 

 

 

Osprey Medical, Inc.  
5600 Rowland Road, Suite 250

 

Minnetonka, MN 55343  
USA  

Customer Service Toll-Free: 

 1-855-860-7584 Fax: 1-855-883-4365 

[email protected] 

  

www.ospreymed.com

 

 

 
 
 
 
 
 
Osprey & DyeTect are trademarks of Osprey Medical Inc. 
©Osprey Medical Inc. 2019. All Rights Reserved. 

 
 

NOTE : Translations will be provided upon approval of english content. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

MedPass SAS 

95 bis Bd Pereire, 75017 Paris, France 

Australian Sponsor 

Osprey Medical, Pty 

Level 13, 41 Exhibition Street 

Melbourne, Victoria 3000 Australia 

2797 