5
2.4 Technical data
NRF no. Product code:
Capacity
persons
Weight
kg.
Diameter x height
mm
Freight
vol.
m³
Heating time,
hours
D
t 65°C
Actual
vol. l.
800 1873 MGC 600 - 15 kW / HX 4.6 m²
-
164
ø 780x2030
1.28
-
557
800 1854 MGC 1000 - 15 kW / HX 4.6 m²
-
265
ø1000x2100
2.29
-
865
Directive: 2010/30/EU Regulation: EU 812/2013
Directive: 2009/125/EC Regulation: EU 814/2013
Heat loss tested acc. to standard: EN 12897: 2015
2. PRODUCT DESCRIPTION
2.1 Product identification
Identification details for your product can be found
on the type plate fixed to the product. The type
plate contains details of the product in accordance
with EN 12897:2016 and EN 60335-2-21, as well as
other useful data. See Declaration of Conformity at
www.osohotwater.com for more information.
OSO products are designed and manufactured in
accordance with:
• Pressure vessel standard
PED 2014/68/EU
• Safety standard
EN 60335-2-21
• Welding standard
EN ISO 3834-2
OSO Hotwater AS is certified for
• Quality
ISO 9001
• Environment
ISO 14001
• Work environment
ISO 45001
2.2 Intended use
The Maxi Geocoil is designed for use as a buffer for
tap water at electrical peak load. The MGC is fitted
for external energy sources.
2.3 CE marking
The CE mark shows that the product complies
with the relevant Directives. See Declaration of
Conformity at www.osohotwater.com for more
information.
The product complies with EU Directives for:
• Low voltage
LVD 2014/35/EU
• Electromagnetic compatibility EMC 2014/30/EU
• Pressurised equipment
PED 2014/68/EU
The safety valve(s) used must be CE marked and
conform to PED 2014/68/EU.
The products are classified as IP21.