Oslo OSP1-08 Скачать руководство пользователя страница 11

1.3

 

Installation of the unit   

                       

1. 

Move the unit together with its exhaust hose assembly in front of the window and keep the unit at least 50cm 

away from the walls or other objects.   

2. 

Install the rectangle end of exhaust hose adapter into the corresponding rectangle hole in window seal-plate 

assembly, fix it with screw and close the window. 

A.  Align the 4 locks on window seal-plate with corresponding 4 fasteners on exhaust hose adapter and set 

them together, then slide adapter downwards. 

B.  Lock self-tapping screw 

φ4mm into adapter hole.   

3. 

Remarks:   

 

Slide the adapter downwards and assure the adapter installed in good position. 

 

Lock the 

φ4 screw tightly to avoid fall off. 

 

Exhaust hose can’t be bent or with flexure higher than 45°, in order to keep good ventilation of exhaust 

hose.   

   

 

 

Important notes: 

The exhaust hose is 280mm-1500mm long and which  is determined by the  specification of the 

air-conditioner (s). Do not use prolonged the hose or replace it with other different hoses as this may affect the 

functions of the air-conditioner. The exhaust hose must be smooth or it may lead air-conditioner overheat and 

trip because exhaust hose is obstructed. 

 

 

 

10

Содержание OSP1-08

Страница 1: ...l Thank you very much for selecting this new model of Portable Air Conditioner please read this Use and Care Manual carefully before installing and using this appliance Please keep this Use and Care M...

Страница 2: ...ification 3 Features and Identification of Parts 4 Operation and Settings 5 Protection 7 Handling and Transportation 8 Installation and Adjustment 9 Drainage Instruction 11 Maintenance and Service 13...

Страница 3: ...conditioner follow up these basic precautions Indoor use only it is prohibited to use this unit outdoors or in humid environment such as bathroom etc Do not remove ground prong Do not use an adapter D...

Страница 4: ...efore disassembling or installing the filter Remark Do not use this unit in cooling mode if the ambient temperature is higher than 35 Function and Technical Specification This unit offers cooling heat...

Страница 5: ...ll 4 Universal wheel 5 Back shell 6 Handle 7 Filter 8 Universal socket 9 Wire winding pillar 10 Drain hole and cover 11 Up filter assemble 12 Down filter assembly 13 Chassis 14 Remote control 15 Exhau...

Страница 6: ...2 Press the UP DOWN arrow buttons to select the number of hours you want the unit to continue to operate before turning on Note wait approximately 5 seconds for the Turn On time to be saved To clean t...

Страница 7: ...power supply F CONTROL PANEL DISPLAY Displays the set temperature in degrees Fahrenheit or degrees Celsius or the hours remaining in a Time Delay The corresponding indicator light will illuminate 2 Re...

Страница 8: ...lace Notes Use alkaline batteries only Do not use rechargeable batteries When replace batteries always replace both batteries with new batteries do not mix old and new batteries If the air conditioner...

Страница 9: ...E1 If sensors test ok unit restore original state of work or enter into standby state when energized Handling and Transportation 1 Handle and move the unit 1 Hold handles on side panels to move the u...

Страница 10: ...xhaust hose assembly and its adapter 1 Take out the exhaust hose assembly and its adapter from plastic bag 2 Extend the exhaust hose at one end screw the round end of adapter into exhaust hose at anti...

Страница 11: ...er downwards B Lock self tapping screw 4mm into adapter hole 3 Remarks Slide the adapter downwards and assure the adapter installed in good position Lock the 4 screw tightly to avoid fall off Exhaust...

Страница 12: ...pper properly 3 Tilt the unit slightly backwards when draining 4 Block the drain hole as soon as possible before the tray is full if it can t hold all water in the unit to prevent the water leakage an...

Страница 13: ...Pull the drain hose to bathroom or outdoor Notes 1 Drain hose must be installed before unit starts working 2 Put the drain hose in an inaccessible place not higher than water outlet and keep drain ho...

Страница 14: ...filter 1 Grip the filter handle and take it out gently in correct direction shown by the arrow 2 Hold hand positions with your hands take filters out in correct direction shown by the arrow Note 1 Us...

Страница 15: ...ar insert the plug into the universal fixing hole at the back panel of the unit install the water plug and drain cap 4 Remove the heat exhaust hose assembly clean and keep it properly Note 1 Hold the...

Страница 16: ...e the filter Air inlet or air outlet clogged Remove the obstruction High noise level The unit is being placed at uneven surface Put the unit at a flat and firm place may reduce noise The compressor do...

Страница 17: ...otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship Damage caused by consumer misuse tampering or failure to follow the care and special hand...

Отзывы: